PROCEDURE
DRAIN COOLANT (for Inverter)
REMOVE INVERTER RESERVE TANK ASSEMBLY
Remove the 2 bolts and inverter reserve tank assembly.
REMOVE INVERTER WATER PUMP ASSEMBLY
Disconnect the water hose from the inverter water pump assembly.
Note
Put pieces of cloth into the pipe and in the disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.
Disconnect the connector from the inverter water pump assembly.
Note
Apply insulating tape to the connectors of the wire harness and inverter water pump assembly to prevent the entry of coolant.
Remove the 3 bolts from the inverter water pump assembly.
Disconnect the water hose from the inverter water pump assembly and remove the inverter water pump assembly.
Note
Put pieces of cloth into the pipe and in the disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.