BLOWER UNIT(for DENSO Made) DISASSEMBLY

Info Added 2017-10-06

PROCEDURE


  1. PRECAUTION

    Note

    Make sure to perform initialization after replacing the No. 1 blower damper servo sub-assembly. If initialization is not performed, the air conditioner unit assembly will not perform properly as the air conditioning amplifier assembly will not be able to recognize the position of the No. 1 blower damper servo sub-assembly.

  2. REMOVE AIR FILTER COVER PLATE


    1. A001SNKC02
      B00497S Remove in this Direction (1)
      B0049AC Remove in this Direction (2)

      Disengage the claw and guides as indicated by the arrows, in the order shown in the illustration to remove the air filter cover plate.

  3. REMOVE CLEAN AIR FILTER


    1. A001SZ7C02
      B00497S Remove in this Direction

      Remove the air filter sub-assembly as shown in the illustration.

    2. A001UMA

      Disengage the guides to remove the clean air filter from the cooling unit parts.

  4. REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY


    1. A001V2Q

      Remove the 3 screws and blower motor with fan sub-assembly.

  5. REMOVE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY


    1. A001XH7

      Remove the 2 screws and No. 1 blower damper servo sub-assembly.