AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) DATA LIST / ACTIVE TEST


  1. DATA LIST

    Note

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

    Tech Tips

    Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch ON.

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    5. Read the Data List according to the display on the GTS.


      Body Electrical > Air Conditioner > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Ambient Temp Sensor Thermistor assembly

      Min.: -23.30°C (-9.94°F)

      Max.: 65.95°C (150.71°F)

      Actual ambient temperature displayed -
      Adjusted Ambient Temp Adjusted ambient temperature

      Min.: -30.80°C (-23.44°F)

      Max.: 50.80°C (123.44°F)

      - -
      Evaporator Fin Thermistor No. 1 cooler thermistor (evaporator temperature sensor)

      Min.: -29.70°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual evaporator temperature displayed *2
      Evaporator Target Temp Evaporator target temperature

      Min.: -327.68°C (-557.82°F)

      Max.: 327.67°C (621.81°F)

      Evaporator target temperature displayed *2
      Regulator Control Current Solenoid valve control current

      Min.: 0 A

      Max.: 0.997 A

      Value changes between 0 A and 0.997 A in accordance with solenoid valve operation *2
      Electric Heater Count Maximum electric heater operation level

      Min.: 0

      Max.: 3

      Maximum possible operation level of electric heater displayed *1
      Electric Heater Active Level Actual electric heater operation level

      Min.: 0

      Max.: 3

      Actual operation level of electric heater displayed *1
      A/C Cutoff Signal A/C control cutoff signal ON or OFF

      A/C switch on: OFF

      A/C switch off: ON

      *2
      Refrigerant Gas Type Refrigerant gas type R134a or 1234yf Refrigerant gas type displayed *2
      Number of Trouble Codes Number of trouble codes

      Min.: 0

      Max.: 255

      Number of DTCs displayed -
      Upper Air Mix Target Position (Driver Side) No. 1 air conditioning radiator damper servo sub-assembly (upper air mix) target position

      Min.: 0

      Max.: 100


      • MAX COLD: 0 (%)

      • MAX HOT: 100 (%)

      -
      Upper Air Mix Current Position (Driver Side) No. 1 air conditioning radiator damper servo sub-assembly (upper air mix) current position

      Min.: 0

      Max.: 100


      • MAX COLD: 0 (%)

      • MAX HOT: 100 (%)

      -
      Lower Air Mix Target Position (Driver Side) No. 1 air conditioning radiator damper servo sub-assembly (lower air mix) target position

      Min.: 0

      Max.: 100


      • MAX COLD: 0 (%)

      • MAX HOT: 100 (%)

      -
      Lower Air Mix Current Position (Driver Side) No. 1 air conditioning radiator damper servo sub-assembly (lower air mix) current position

      Min.: 0

      Max.: 100


      • MAX COLD: 0 (%)

      • MAX HOT: 100 (%)

      -
      Front Air Outlet Target Position No. 2 air conditioning radiator damper servo sub-assembly (mode switching) target position

      Min.: 0

      Max.: 100


      • FACE: 0 (%)

      • B/L: 36 (%)

      • FOOT: 61 (%)

      • FOOT/DEF: 71 (%)

      • DEF: 100 (%)

      -
      Front Air Outlet Current Position No. 2 air conditioning radiator damper servo sub-assembly (mode switching) actual position

      Min.: 0

      Max.: 100


      • FACE: 0 (%)

      • B/L: 36 (%)

      • FOOT: 61 (%)

      • FOOT/DEF: 71 (%)

      • DEF: 100 (%)

      -
      Air Inlet Target Position No. 1 blower damper servo sub-assembly target position

      Min.: 0

      Max.: 100

      w/o Headlight Cleaner System


      • Recirculation: 100 (%)

      • Fresh: 0 (%)

      w/ Headlight Cleaner System


      • Recirculation: 50 (%)

      • Bi-layer: 100 (%)

      • Fresh: 0 (%)

      -
      Air Inlet Current Position No. 1 blower damper servo sub-assembly current position

      Min.: 0

      Max.: 100

      w/o Headlight Cleaner System


      • Recirculation: 100 (%)

      • Fresh: 0 (%)

      w/ Headlight Cleaner System


      • Recirculation: 50 (%)

      • Bi-layer: 100 (%)

      • Fresh: 0 (%)

      -
      Engine Coolant Temperature Engine coolant temperature sensor

      Min.: 0.5°C (32.9°F)

      Max.: 127.5°C (261.5°F)

      Actual engine coolant temperature displayed -
      Regulator Pressure Sensor Air conditioner pressure sensor

      Min.: 0 kPa

      Max.: 3760 kPa

      Actual refrigerant pressure displayed -
      Air Outlet Target Temperature (Driver Side) Air outlet target temperature

      Min.: -327.68°C (-557.82°F)

      Max.: 327.67°C (621.81°F)

      Actual air outlet target temperature displayed -

      • *1: w/ PTC Heater

      • *2: w/ Cooler System

  2. ACTIVE TEST

    Tech Tips

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch ON.

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. Perform the Active Test according to the display on the GTS.


      Body Electrical > Air Conditioner > Active Test
      Tester Display Measurement Item Control Range Diagnostic Note
      Magnetic Clutch Relay Air conditioning system operation OFF or ON *2
      Heater Active Level Quick heater assembly OFF or ON *1
      Blower Motor Blower motor with fan sub-assembly

      Min.: 0

      Max.: 100

      Operates between

      0 to 100%

      Air Inlet No. 1 blower damper servo sub-assembly (fresh/recirculation)

      Min.: 0

      Max.: 100

      Operates between

      0 to 100%

      Air Outlet (Front) No. 2 air conditioning radiator damper servo sub-assembly (mode switching)

      Min.: 0

      Max.: 100

      Operates between

      0 to 100%

      Upper Air Mix (Driver Side) No. 1 air conditioning radiator damper servo sub-assembly (upper air mix)

      Min.: 0

      Max.: 100

      Operates between

      0 to 100%

      Lower Air Mix (Driver Side) No. 1 air conditioning radiator damper servo sub-assembly (lower air mix)

      Min.: 0

      Max.: 100

      Operates between

      0 to 100%


      • *1: w/ PTC Heater

      • *2: w/ Cooler System