| B1411 |
Room Temperature Sensor Circuit |
Any of the following conditions is met:
|
Click here
|
| B1412 |
Ambient Temperature Sensor Circuit |
When the air conditioning amplifier assembly receives out-of-range outside temperature sensor data from the combination meter assembly. |
Click here
|
| B1413 |
Evaporator Temperature Sensor Circuit |
Any of the following conditions is met:
|
Click here
|
| B1423 |
Pressure Sensor Circuit |
Any of the following conditions is met:
-
Open in air conditioner pressure sensor circuit (Only when the outside temperature is 5 °C (41°F) or more)
-
Short in air conditioner pressure sensor circuit (Only when the outside temperature is 5 °C (41°F) or more)
-
for HFC-134a (R134a): Refrigerant pressure on high pressure side is extremely low (176 kPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3025 kPa (30.8 kgf/cm2, 439 psi) or more) (Only when the outside temperature is 5 °C (41°F) or more)
-
for HFO-1234yf (R1234yf): Refrigerant pressure on high pressure side is extremely low (195 kPa (2.0 kgf/cm2, 28 psi) or less) or extremely high (2812 kPa (28.7 kgf/cm2, 408 psi) or more) (Only when the outside temperature is 5 °C (41°F) or more)
|
Click here
|
| B1441 |
Air Mix Damper Control Servo Motor Circuit (Passenger Side) |
Any of the following conditions is met:
-
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) drive terminal is open circuit
-
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) drive terminal is short circuit
|
Click here
|
| B1442 |
Air Inlet Damper Control Servo Motor Circuit |
Any of the following conditions is met:
|
Click here
|
| B1443 |
Air Outlet Damper Control Servo Motor Circuit |
Any of the following conditions is met:
-
No. 2 air conditioning radiator damper servo sub-assembly (mode switching) drive terminal is open circuit
-
No. 2 air conditioning radiator damper servo sub-assembly (mode switching) drive terminal is short circuit
|
Click here
|
| B1446 |
Air Mix Damper Control Servo Motor Circuit (Driver Side) |
Any of the following conditions is met:
-
No. 1 air conditioning radiator damper servo sub-assembly (driver side upper air mix) drive terminal is open circuit
-
No. 1 air conditioning radiator damper servo sub-assembly (driver side upper air mix) drive terminal is short circuit
|
Click here
|
| B1451 |
Compressor Solenoid Circuit |
Any of the following conditions is met:
|
Click here
|
| B1453 |
Air Outlet Damper Cool Control Servo Motor Circuit (Driver Side) |
Any of the following conditions is met:
-
No. 1 air conditioning radiator damper servo sub-assembly (driver side lower air mix) drive terminal is open circuit
-
No. 1 air conditioning radiator damper servo sub-assembly (driver side lower air mix) drive terminal is short circuit
|
Click here
|
| B1454 |
Air Outlet Damper Cool Control Servo Motor Circuit (Passenger Side) |
Any of the following conditions is met:
-
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) drive terminal is open circuit
-
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) drive terminal is short circuit
|
Click here
|
| B14B2 |
Lost Communication with Front Panel LIN |
Lost communication with air conditioning control assembly |
Click here
|
| B14B9 |
Open in Ion Generator Circuit |
Open in ion generator sub-assembly circuit |
Click here
|
| U0100 |
Lost Communication with ECM |
No communication with ECM |
Click here
|
| U0131 |
Lost Communication with Electric Power Steering ECU |
No communication with power steering ECU assembly |
Click here
|
| U0142 |
Lost Communication with Main Body ECU |
No communication with main body ECU (multiplex network body ECU) |
Click here
|
| U0155 |
Lost Communication with Combination Meter |
No communication with combination meter assembly |
Click here
|