METER / GAUGE SYSTEM Entire Combination Meter does not Operate

DESCRIPTION

This circuit is the power source circuit for the combination meter assembly. This circuit provides two types of power sources; one is a constant power source, and the other is an IG power source.

WIRING DIAGRAM

A001WD8E03

CAUTION / NOTICE / HINT

Note


  • Inspect the fuses of circuits related to this system before performing the following procedure.

  • When replacing the combination meter assembly, always replace it with a new one. If a combination meter assembly which was installed to another vehicle is used, the information stored in it will not match the information from the vehicle and a DTC may be stored.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)


    1. Disconnect the F4 combination meter assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F4-21 (ET) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      F4-39 (IG+) - Body ground Ignition switch off Below 1 V
      Ignition switch ON 11 to 14 V
      F4-40 (B) - Body ground Always 11 to 14 V
      Result
      Proceed to
      OK
      NG

    OK
    NG