RELAY INSPECTION

PROCEDURE


  1. INSPECT SECURITY WARNING RELAY


    1. A001VHFN47

      Check the resistance.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Connection
        3 - 5 Battery voltage applied to terminal 1 and 2 Below 1 Ω
        3 - 5 Battery voltage not applied to terminal 1 and 2 10 kΩ or higher

        • If the result is not as specified, replace the security warning relay.