PROCEDURE
REMOVE NO. 2 INSTRUMENT PANEL LOWER FINISH PANEL
REMOVE ECU INTEGRATION BOX RH
| *a | w/ Smart Key System |
| *b | w/ Stop and Start System |
Disconnect the connector.
w/ Smart Key System:
Disconnect the 3 connectors.
w/ Stop and Start System:
Disconnect the 3 connectors.
Using a clip remover, disengage the wire harness clamp.
Using a clip remover, disengage the wire harness clamps.
Remove the bolt, 2 nuts and ECU integration box RH.
REMOVE CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU)
Disengage the claws to remove the central gateway ECU (network gateway ECU).
Note
If the ECU integration box RH is deformed or damaged, replace it.
Do not bend the claws more than necessary.