LIN COMMUNICATION SYSTEM, Diagnostic DTC:B1206

DTC Code DTC Name
B1206 P/W Master Switch Communication Stop

DESCRIPTION

This DTC is stored when LIN communication between the multiplex network master switch assembly and main body ECU (multiplex network body ECU) stops for 10 seconds or more.

DTC No. Detection Item DTC Detection Condition Trouble Area
B1206 P/W Master Switch Communication Stop No communication between multiplex network master switch assembly and main body ECU (multiplex network body ECU) for 10 seconds or more.
  • Multiplex network master switch assembly

  • Main body ECU (multiplex network body ECU)

  • Instrument panel junction block assembly

  • Wire harness or connector

  • ECU-B NO. 2 fuse

WIRING DIAGRAM


  1. A001TVBE05

CAUTION / NOTICE / HINT

Note


  • Inspect the fuses for circuits related to this system before performing the following procedure.

  • If the main body ECU (multiplex network body ECU) is replaced, refer to Service Bulletin.*1


  • *1: w/ Entry and Start System

PROCEDURE


  1. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


    1. Remove the instrument panel junction block assembly.


      A001T1UC10
      *a

      Component without harness connected

      (Instrument Panel Junction Block Assembly)

      - -
    2. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.

    3. Measure the resistance according to the value(s) in the table below.

      Tech Tips

      This inspection is to check the LIN communication line in the instrument panel junction block assembly that connects the wire harness to the built-in main body ECU (multiplex network body ECU).

      Standard Resistance
      Tester Connection Condition Specified Condition
      3H-25 - MB-16 (LIN2) Always Below 1 Ω
      Result
      Result Proceed to
      OK A
      NG (for LHD) B
      NG (for RHD) C

    B
    C
    A
  2. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY)


    1. for LHD


      1. Disconnect the J6 multiplex network master switch assembly connector.

      2. Measure the resistance according to the value(s) in the table below.

        Note

        Make sure that each ECU is in sleep mode before performing the inspection. To enter sleep mode, turn the ignition switch from ON to off and wait for 180 seconds or more without operating any switches.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        3H-25 - J6-17 (LIN1) Ignition switch off Below 1 Ω
        J6-17 (LIN1) or 3H-25 - Body ground Ignition switch off 10 kΩ or higher
    2. for RHD


      1. Disconnect the I6 multiplex network master switch assembly connector.

      2. Measure the resistance according to the value(s) in the table below.

        Note

        Make sure that each ECU is in sleep mode before performing the inspection. To enter sleep mode, turn the ignition switch from ON to off and wait for 180 seconds or more without operating any switches.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        3H-25 - I6-17 (LIN1) Ignition switch off Below 1 Ω
        I6-17 (LIN1) or 3H-25 - Body ground Ignition switch off 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY - BATTERY, BODY GROUND)


    1. for LHD


      1. Measure the voltage according to the value(s) in the table below.

        Standard Voltage
        Tester Connection Condition Specified Condition
        J6-11 (B) - J6-12 (GND) Always 11 to 14 V
      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        J6-12 (GND) - Body ground Always Below 1 Ω
    2. for RHD


      1. Measure the voltage according to the value(s) in the table below.

        Standard Voltage
        Tester Connection Condition Specified Condition
        I6-11 (B) - I6-12 (GND) Always 11 to 14 V
      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        I6-12 (GND) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY


    1. Replace the multiplex network master switch assembly.

      Click here

      Result
      Proceed to
      NEXT

    NEXT
  5. CHECK FOR DTC


    1. Clear the DTCs.

      Click here


      Body Electrical > Main Body > Clear DTCs
    2. Recheck for DTCs.


      Body Electrical > Main Body > Trouble Codes
      OK
      DTC B1206 is not output.
      Result
      Result Proceed to
      OK A
      NG (for LHD) B
      NG (for RHD) C

    A
    B
    C