PARK / NEUTRAL POSITION SWITCH INSPECTION

PROCEDURE


  1. INSPECT PARK/NEUTRAL POSITION SWITCH


    1. A001WO0C24
      *a

      Component without harness connected

      (Park/Neutral Position Switch)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (B) - 9 (L) Shift lever in P or N Below 1 Ω
      Shift lever not in P and N 10 kΩ or higher
      1 (RB) - 3 (PL) Shift lever in P Below 1 Ω
      Shift lever not in P 10 kΩ or higher
      1 (RB) - 2 (RL) Shift lever in R Below 1 Ω
      Shift lever not in R 10 kΩ or higher
      1 (RB) - 8 (NL) Shift lever in N Below 1 Ω
      Shift lever not in N 10 kΩ or higher
      1 (RB) - 7 (DL) Shift lever in D or M Below 1 Ω
      Shift lever not in D and M 10 kΩ or higher

      If the result is not as specified, replace the park/neutral position switch.