STOP AND START SYSTEM Engine Hood Courtesy Switch Circuit

DESCRIPTION

The engine stop and start ECU detects whether the engine hood is open or closed based on a signal received from the engine hood courtesy switch built into the hood lock assembly.


WIRING DIAGRAM

A001XAZE60

PROCEDURE


  1. READ VALUE USING GTS (HOOD COURTESY SWITCH)

    Note

    Before performing this step, check that the engine hood can be opened by pulling the hood lock control cable.


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / Stop and Start / Data List / Hood Courtesy Switch.

    5. According to the display on the GTS, read the Data List.


      Powertrain > Stop and Start > Data List
      Tester Display
      Hood Courtesy Switch
      OK
      Tester Display Condition Normal Condition
      Hood Courtesy Switch Engine hood closed ON
      Engine hood open OFF
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. INSPECT HOOD LOCK ASSEMBLY (ENGINE HOOD COURTESY SWITCH)


    1. Remove the hood lock assembly (hood courtesy switch).

      Click here

    2. Inspect the hood lock assembly (hood courtesy switch).

      Click here

      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (HOOD LOCK ASSEMBLY (HOOD COURTESY SWITCH) - BODY GROUND)


    1. Disconnect the A8 hood lock assembly (hood courtesy switch) connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A8-2 (E) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - ENGINE HOOD COURTESY SWITCH (HOOD LOCK ASSEMBLY))


    1. Disconnect the A62 engine stop and start ECU connector.

    2. Disconnect the A8 hood lock assembly (hood courtesy switch) connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A62-7 (BNT1) - A8-1 (+) Always Below 1 Ω
      A62-7 (BNT1) - Body ground and other terminals Always 10 kΩ or higher
      A8-1 (+) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG