RELAY INSPECTION

PROCEDURE


  1. INSPECT STARTER RELAY ASSEMBLY


    1. A001TU5E26

      Check the resistance.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
        3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω

        If the result is not as specified, replace the starter relay assembly.