RELAY ON-VEHICLE INSPECTION

PROCEDURE


  1. INSPECT FAN NO. 1 RELAY


    1. Check the resistance.


      1. A001TU5E24

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
        3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω

        If the result is not as specified, replace the fan No. 1 relay.