PROCEDURE
INSTALL NO. 2 ECM BRACKET
Install the No. 2 ECM bracket to the ECM with the 2 screws.
INSTALL NO. 1 ECM BRACKET
Install the No. 1 ECM bracket to the ECM with the 2 screws.
INSTALL ECM
Install the ECM with the bolt and nut.
Note
If the ECM has been struck or dropped, replace it.
Engage the 2 claws to connect the engine wire to the No. 1 engine room relay block.
Connect the 3 connectors to the engine room relay block assembly.
Install the No. 1 relay block cover to the No. 1 engine room relay block.
Connect the 2 ECM connectors and lower the 2 levers.
Note
When connecting the ECM connectors, make sure that dirt, water or other foreign matter does not contact the connecting parts of the ECM connectors.
Be sure to securely connect the ECM connectors.
INSTALL AIR CLEANER CASE SUB-ASSEMBLY
Install the air cleaner case sub-assembly to the vehicle with the 2 bolts.
Install the air cleaner filter element sub-assembly to the air cleaner case sub-assembly.
INSTALL NO. 1 AIR CLEANER INLET
INSTALL RADIATOR COVER
INSTALL AIR CLEANER CAP WITH AIR CLEANER HOSE
INSTALL NO. 2 CYLINDER HEAD COVER
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
PERFORM INITIALIZATION