ECM INSTALLATION

PROCEDURE


  1. INSTALL NO. 2 ECM BRACKET


    1. Install the No. 2 ECM bracket to the ECM with the 2 screws.

      Torque:
      4.5 N*m  { 46 kgf*cm, 40 in.*lbf }
  2. INSTALL NO. 1 ECM BRACKET


    1. Install the No. 1 ECM bracket to the ECM with the 2 screws.

      Torque:
      4.5 N*m  { 46 kgf*cm, 40 in.*lbf }
  3. INSTALL ECM


    1. Install the ECM with the bolt and nut.

      Torque:
      Bolt
      12.5 N*m  { 127 kgf*cm, 9 ft.*lbf }
      Nut
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }

      Note

      If the ECM has been struck or dropped, replace it.

    2. Engage the 2 claws to connect the engine wire to the No. 1 engine room relay block.

    3. Connect the 3 connectors to the engine room relay block assembly.

    4. Install the No. 1 relay block cover to the No. 1 engine room relay block.

    5. A001WNP

      Connect the 2 ECM connectors and lower the 2 levers.

      Note


      • When connecting the ECM connectors, make sure that dirt, water or other foreign matter does not contact the connecting parts of the ECM connectors.

      • Be sure to securely connect the ECM connectors.

  4. INSTALL AIR CLEANER CASE SUB-ASSEMBLY


    1. Install the air cleaner case sub-assembly to the vehicle with the 2 bolts.

      Torque:
      4.0 N*m  { 41 kgf*cm, 35 in.*lbf }
    2. Install the air cleaner filter element sub-assembly to the air cleaner case sub-assembly.

  5. INSTALL NO. 1 AIR CLEANER INLET

    Click here

  6. INSTALL RADIATOR COVER

    Click here

  7. INSTALL AIR CLEANER CAP WITH AIR CLEANER HOSE

    Click here

  8. INSTALL NO. 2 CYLINDER HEAD COVER

    Click here

  9. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Click here

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  10. PERFORM INITIALIZATION

    Click here