HAZARD WARNING SWITCH INSPECTION

PROCEDURE


  1. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY


    1. Check the resistance.


      1. A001WVCC10
        *a

        Component without harness connected

        (Hazard Warning Signal Switch Assembly)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        4 (TB) - 1 (E) Hazard warning signal switch off 10 kΩ or higher
        Hazard warning signal switch on Below 1 Ω

        If the result is not as specified, replace the hazard warning signal switch assembly.

    2. Check that the illumination lights.


      1. Apply battery voltage to the hazard warning signal switch assembly and check that the switch illuminates.

        OK
        Condition Specified Condition

        Battery positive (+) → Terminal 3 (ILL+)

        Battery negative (-) → Terminal 2 (ILL-)

        Illuminates