| Capacity | Classification |
|---|---|
| 5.7 liters (6.1 US qts, 5.1 Imp. qts) | Use only "TOYOTA Super Long Life Coolant", or similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, and non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of low phosphates and organic acids). |
| Condition | Specified Condition | |
|---|---|---|
| Standard valve opening temperature | 78 to 82°C (172 to 180°F) | |
| Standard valve lift | for Type A | 10 mm (0.394 in.) or more at 93°C (199°F) |
| for Type B | 10 mm (0.394 in.) to 14 mm (0.551 in.) at 95°C (203°F) | |
| Item | Condition | Specified Condition |
|---|---|---|
| Cooling fan motor | Battery voltage applied at 20°C (68°F) | 7.4 to 10.9 A |
| Item | Condition | Specified Condition |
|---|---|---|
| Cooling fan motor | Battery voltage applied at 20°C (68°F) | 7.4 to 10.9 A |
| Item | Condition | Specified Condition |
|---|---|---|
| Radiator cap | Standard value (for brand-new radiator cap sub-assembly) | 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.5 to 17 psi) |
| Minimum standard value (for radiator cap sub-assembly) | 79 kPa (0.8 kgf/cm2, 11.4 psi) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω |