LIGHTING SYSTEM Hazard Warning Switch Circuit

DESCRIPTION

The combination meter assembly (meter circuit plate) receives the hazard warning signal switch assembly on signal and controls the operation of the hazard warning lights.

WIRING DIAGRAM

A003L3LE09

PROCEDURE


  1. READ VALUE USING GTS


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Combination Meter / Data List.

    5. Read the Data List according to the display on the GTS.


      Body Electrical > Combination Meter > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Hazard Flasher Switch Hazard warning signal switch signal OFF or ON

      OFF: Hazard warning signal switch off

      ON: Hazard warning signal switch on

      -

      Body Electrical > Combination Meter > Data List
      Tester Display
      Hazard Flasher Switch
      OK
      Normal conditions listed above are displayed.
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY


    1. Remove the hazard warning signal switch assembly.

      Click here

    2. Inspect the hazard warning signal switch assembly.

      Click here

      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (HAZARD WARNING SIGNAL SWITCH ASSEMBLY - COMBINATION METER ASSEMBLY (METER CIRCUIT PLATE) AND BODY GROUND)


    1. Disconnect the I7 combination meter assembly (meter circuit plate) connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      V1-5 (TB) - I7-10 (HAZ) Always Below 1 Ω
      V1-5 (TB) or I7-10 (HAZ) - Body ground Always 10 kΩ or higher
      V1-4 (E) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG