DESCRIPTION
The combination meter assembly (meter circuit plate) receives the hazard warning signal switch assembly on signal and controls the operation of the hazard warning lights.
WIRING DIAGRAM
PROCEDURE
READ VALUE USING GTS
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Combination Meter / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Hazard Flasher Switch | Hazard warning signal switch signal | OFF or ON | OFF: Hazard warning signal switch off ON: Hazard warning signal switch on |
- |
| Tester Display |
|---|
| Hazard Flasher Switch |
| OK |
|---|
| Normal conditions listed above are displayed. |
| Result | |||
|---|---|---|---|
|
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| NG |
|
INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY
Remove the hazard warning signal switch assembly.
Inspect the hazard warning signal switch assembly.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE HAZARD WARNING SIGNAL SWITCH ASSEMBLY Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (HAZARD WARNING SIGNAL SWITCH ASSEMBLY - COMBINATION METER ASSEMBLY (METER CIRCUIT PLATE) AND BODY GROUND)
Disconnect the I7 combination meter assembly (meter circuit plate) connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE COMBINATION METER ASSEMBLY (METER CIRCUIT PLATE) Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |