PROCEDURE
INSTALL EVAPORATOR PRESSURE REGULATOR
Remove the vinyl tape from the cooler refrigerant suction pipe A and cooler refrigerant suction pipe B.
Sufficiently apply compressor oil to 2 new O-rings and the fitting surfaces of the cooler refrigerant suction pipe A and cooler refrigerant suction pipe B.
| Compressor Oil |
|---|
| ND-OIL 11 or equivalent |
Install the 2 O-rings to the cooler refrigerant suction pipe A and cooler refrigerant suction pipe B.
Note
Keep the O-rings and O-ring fitting surfaces free of foreign matter.
| *a | Reference Point |
Connect the cooler refrigerant suction pipe A and cooler refrigerant suction pipe B as shown in the illustration.
Note
Install the evaporator pressure regulator with the arrow facing front.
Install the evaporator pressure regulator with the 2 bolts.
INSTALL NO. 2 COOLER PIPE PACKING
Remove any remaining No. 2 cooler pipe packing from the evaporator pressure regulator and cooler refrigerant suction pipe A.
Remove the release paper from a new No. 2 cooler pipe packing.
| *1 | No. 2 Cooler Pipe Packing |
| *2 | Evaporator Pressure Regulator |
| *a | View B |
| *b | Installation Angle (120°) |
Install the No. 2 cooler pipe packing as shown in the illustration.
| Dimension | Measurement |
|---|---|
| A | 60.0 to 70.0 mm (2.36 to 2.76 in.) |
CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
for HFC-134a (R134a):
for HFO-1234yf (R1234yf):
WARM UP COMPRESSOR
for HFC-134a (R134a):
for HFO-1234yf (R1234yf):
INSPECT FOR REFRIGERANT LEAK
for HFC-134a (R134a):
for HFO-1234yf (R1234yf):