PROCEDURE
INSTALL DISCHARGE TEMPERATURE SENSOR
Install the discharge temperature sensor with the piping clamp.
INSTALL COOLER PACKING
Remove any remaining cooler packing from the discharge temperature sensor and No. 1 discharge tube.
Remove the release paper from a new cooler packing.
for LHD:
| *1 | Discharge Temperature Sensor |
| *2 | Piping Clamp |
| *3 | Cooler Packing |
| *4 | No. 1 Discharge Tube |
| *a | View A |
Install the cooler packing as shown in the illustration.
Note
Make sure to install the cooler packing so that its ends are on the opposite side of the discharge temperature sensor as shown in the illustration.
for RHD:
| *1 | Discharge Temperature Sensor |
| *2 | Piping Clamp |
| *3 | Cooler Packing |
| *4 | No. 1 Discharge Tube |
| *a | View A |
Install the cooler packing as shown in the illustration.
Note
Make sure to install the cooler packing so that its ends are on the opposite side of the discharge temperature sensor as shown in the illustration.
INSTALL NO. 1 DISCHARGE TUBE
INSTALL GROMMET
INSTALL AIR CONDITIONER UNIT ASSEMBLY