DISCHARGE TEMPERATURE SENSOR INSTALLATION

PROCEDURE


  1. INSTALL DISCHARGE TEMPERATURE SENSOR


    1. Install the discharge temperature sensor with the piping clamp.

  2. INSTALL COOLER PACKING


    1. Remove any remaining cooler packing from the discharge temperature sensor and No. 1 discharge tube.

    2. Remove the release paper from a new cooler packing.

    3. for LHD:


      1. A003L3FC01
        *1 Discharge Temperature Sensor
        *2 Piping Clamp
        *3 Cooler Packing
        *4 No. 1 Discharge Tube
        *a View A

        Install the cooler packing as shown in the illustration.

        Note

        Make sure to install the cooler packing so that its ends are on the opposite side of the discharge temperature sensor as shown in the illustration.

    4. for RHD:


      1. A003ML3C02
        *1 Discharge Temperature Sensor
        *2 Piping Clamp
        *3 Cooler Packing
        *4 No. 1 Discharge Tube
        *a View A

        Install the cooler packing as shown in the illustration.

        Note

        Make sure to install the cooler packing so that its ends are on the opposite side of the discharge temperature sensor as shown in the illustration.

  3. INSTALL NO. 1 DISCHARGE TUBE

    Click here

  4. INSTALL GROMMET

    Click here

  5. INSTALL AIR CONDITIONER UNIT ASSEMBLY

    Click here