PROCEDURE
INSTALL LOW PRESSURE MAGNETIC VALVE
Remove the vinyl tape from the low pressure magnetic valve.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the No. 4 connector tube.
| Compressor Oil |
|---|
| ND-OIL 11 or equivalent |
Install the O-ring to the No. 4 connector tube.
Note
Keep the O-ring and O-ring fitting surface free of foreign matter.
| *a | Reference Point |
Install the low pressure magnetic valve with the bolt.
Note
Make sure to install the low pressure magnetic valve with the arrow facing the direction shown in the illustration.
Remove the vinyl tape from the valve to connector tube.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the valve to connector tube.
Install the O-ring to the valve to connector tube.
Note
Keep the O-ring and O-ring fitting surface free of foreign matter.
Install the low pressure magnetic valve and connector tube with the bolt.
INSTALL NO. 3 CONNECTOR TUBE
INSTALL COOLER REFRIGERANT LIQUID PIPE A
INSTALL NO. 1 RECEIVER TANK BRACKET WITH NO. 5 COOLER BRACKET
INSTALL NO. 6 COOLER BRACKET
INSTALL AIR CONDITIONING RECEIVER TANK WITH BRACKET
INSTALL NO. 3 RECEIVER TANK BRACKET
INSTALL ACCUMULATOR AND ACCESSORY ASSEMBLY