PROCEDURE
INSPECT EVAPORATOR TEMPERATURE SENSOR
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected (Evaporator Temperature Sensor) |
*b | Sensing Portion |
| *c | Resistance (kΩ) | *d | Temperature (°C (°F)) |
| *e | Allowable Range | - | - |
| Standard Resistance | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the resistance is not as specified, replace the evaporator temperature sensor.
Note
Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
Tech Tips
As the temperature increases, the resistance decreases (see the graph).