BLOWER UNIT DISASSEMBLY

PROCEDURE


  1. PRECAUTION

    Note

    Make sure to perform initialization after replacing the No. 1 blower damper servo sub-assembly. If initialization is not performed, the air conditioner unit assembly will not perform properly as the air conditioning amplifier assembly will not be able to recognize the position of the No. 1 blower damper servo sub-assembly.

  2. REMOVE AIR FILTER COVER PLATE


    1. A003OMXC01
      B006IFV Remove in this Direction (1)
      B006IV0 Remove in this Direction (2)

      Disengage the claw and 2 guides as indicated by the arrows, in the order shown in the illustration to remove the air filter cover plate.

  3. REMOVE CLEAN AIR FILTER


    1. A003NFJC01
      B006IFV Remove in this Direction

      Remove the air filter sub-assembly as shown in the illustration.

    2. A003N1Y

      Disengage the 4 guides to remove the clean air filter from the cooling unit parts.

  4. REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY


    1. A003NLH

      Remove the 3 screws and blower motor with fan sub-assembly.

  5. REMOVE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY


    1. A003KHA

      Remove the 2 screws and No. 1 blower damper servo sub-assembly.