PROCEDURE
PRECAUTION
Note
Make sure to perform initialization after replacing the No. 1 blower damper servo sub-assembly. If initialization is not performed, the air conditioner unit assembly will not perform properly as the air conditioning amplifier assembly will not be able to recognize the position of the No. 1 blower damper servo sub-assembly.
REMOVE AIR FILTER COVER PLATE
|
Remove in this Direction (1) |
|
Remove in this Direction (2) |
Disengage the claw and 2 guides as indicated by the arrows, in the order shown in the illustration to remove the air filter cover plate.
REMOVE CLEAN AIR FILTER
|
Remove in this Direction |
Remove the air filter sub-assembly as shown in the illustration.
Disengage the 4 guides to remove the clean air filter from the cooling unit parts.
REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY
Remove the 3 screws and blower motor with fan sub-assembly.
REMOVE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY
Remove the 2 screws and No. 1 blower damper servo sub-assembly.