BLOWER UNIT REMOVAL

CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during blower unit removal/installation are shown below.

Necessary Procedure After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedure Effect/Inoperative Function when Necessary Procedure not Performed Link
Disconnect cable from negative auxiliary battery terminal Memorize steering angle neutral point Lane departure alert system (w/ Steering Control)

Click here

Intelligent clearance sonar system*1
Simple intelligent parking assist system*1
Pre-crash safety system
Adaptive high beam system
Parking assist monitor system

Click here

Initialize back door lock Power door lock control system

Click here

No. 1 blower damper servo sub-assembly Initialize servo motor (Air conditioning system) DTCs are stored

Click here

*1: When performing learning using the GTS.
Click here Click here

Tech Tips

Before removing the blower assembly, set the air conditioning to recirculation mode.

PROCEDURE


  1. PRECAUTION

    Note

    Make sure to perform initialization after replacing the No. 1 blower damper servo sub-assembly. If initialization is not performed, the air conditioner unit assembly will not perform properly as the air conditioning amplifier assembly will not be able to recognize the position of the No. 1 blower damper servo sub-assembly.

  2. REMOVE AIR CONDITIONER UNIT ASSEMBLY

    Click here

  3. REMOVE NO. 2 AIR DUCT (for LHD)

    Click here

  4. REMOVE NO. 1 AIR DUCT (for RHD)

    Click here

  5. REMOVE BLOWER ASSEMBLY


    1. for LHD:


      1. A003LK7

        Disconnect the connector.

      2. Disengage the 4 guides.

      3. A003K83

        Remove the 2 screws.

      4. Disengage the 2 claws and 3 guides and remove the blower assembly from the air conditioning radiator assembly.

    2. for RHD:


      1. A003K0O

        Disconnect the connector.

      2. Disengage the 2 guides.

      3. A003LTL

        Remove the 2 screws.

      4. Disengage the 2 claws and 2 guides and remove the blower assembly from the air conditioning radiator assembly.