PROCEDURE
PERFORM MIDDLE DIFFERENTIAL PRESSURE VALVE STATE CHECK
Perform the middle differential pressure valve state check.
| OK |
|---|
| Middle differential pressure valve state check is successful. |
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE NO. 1 AIR CONDITIONING ACCESSORY ASSEMBLY Click here |
| OK |
|
PERFORM ACTIVE TEST USING GTS (COOLING ELECTRIC EXPANSION VALVE)
Set the vehicle so that the following conditions are met.*
| Measurement Condition | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Cooling Electric Expansion Valve | Electric expansion valve (cooling) | Min.: 0% Max.: 100% |
Perform this test with the following conditions met:
|
| Tester Display |
|---|
| Cooling Electric Expansion Valve |
With the measurement conditions* met, according to the display on the GTS, increase the value of Cooling Electric Expansion Valve by 15% and read the Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Evaporator Fin Thermistor | Evaporator temperature sensor | Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | - |
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -0.4566 MPaG Max.: 3.2943 MPaG |
Actual refrigerant pressure displayed | - |
| Cooling Electric Expansion Valve Target Position | Electric expansion valve (cooling) | Min.: 0.00% Max.: 100.00% |
Electric expansion valve (cooling) target position displayed | - |
| Tester Display |
|---|
| Evaporator Fin Thermistor |
| Regulator Pressure Sensor |
| Cooling Electric Expansion Valve Target Position |
| OK |
|---|
| The value of Evaporator Fin Thermistor increases by 3°C (37°F). |
| Result | |||
|---|---|---|---|
|
| NG |
|
CHECK ELECTRIC EXPANSION VALVE (COOLING) Click here |
| OK |
|
READ VALUE USING GTS (EVAPORATOR FIN THERMISTOR)
According to the display on the GTS, decrease the value of Cooling Electric Expansion Valve by 15% and read the Data List.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Evaporator Fin Thermistor | Evaporator temperature sensor | Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | - |
| Tester Display |
|---|
| Evaporator Fin Thermistor |
| OK |
|---|
| The value of Evaporator Fin Thermistor decreases by 3°C (37°F). |
| Result | |||
|---|---|---|---|
|
| NG |
|
GO TO STEP 8 Click here |
| OK |
|
INSPECT LOW PRESSURE MAGNETIC VALVE
Turn the power switch on (READY).
Push the AUTO switch to operate the air conditioning system.
Turn the power switch off and wait for 2 minutes.
Remove the low pressure magnetic valve.
Inspect the low pressure magnetic valve.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE LOW PRESSURE MAGNETIC VALVE Click here |
| OK |
|
LOW PRESSURE MAGNETIC VALVE (POWER SOURCE CIRCUIT)
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Low Pressure Magnetic Valve | Low pressure magnetic valve | OFF or ON | - |
| Tester Display |
|---|
| Low Pressure Magnetic Valve |
| *a | Component without harness connected (Low Pressure Magnetic Valve) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (LOW PRESSURE MAGNETIC VALVE - HEAT PUMP ECU ASSEMBLY)
Disconnect the A42 heat pump ECU assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK VALVE TO CONNECTOR TUBE
Remove the valve to connector tube.
Apply compressed air to the inlet port and then outlet port of the valve to connector tube.
| OK |
|---|
| Air flows out of the outlet port when applied to the inlet port but not out of the inlet port when applied to the outlet port. |
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE EVAPORATOR PRESSURE REGULATOR Click here |
| NG |
|
REPLACE VALVE TO CONNECTOR TUBE Click here |
CHECK ELECTRIC EXPANSION VALVE (COOLING)
Inspect the electric expansion valve (cooling).
| Result | |||
|---|---|---|---|
|
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| NG |
|
REPLACE ELECTRIC EXPANSION VALVE (COOLING) Click here |