PROCEDURE
PERFORM MIDDLE DIFFERENTIAL PRESSURE VALVE STATE CHECK
Perform the middle differential pressure valve state check.
| OK |
|---|
| Middle differential pressure valve state check is successful. |
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE NO. 1 AIR CONDITIONING ACCESSORY ASSEMBLY Click here |
| OK |
|
PERFORM ACTIVE TEST USING GTS (COOLING ELECTRIC EXPANSION VALVE)
Set the vehicle so that the following conditions are met.*
| Measurement Condition | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Cooling Electric Expansion Valve | Electric expansion valve (cooling) | Min.: 0% Max.: 100% |
Perform this test with the following conditions met:
|
| Tester Display |
|---|
| Cooling Electric Expansion Valve |
With the measurement conditions* met, according to the display on the GTS, increase the value of Cooling Electric Expansion Valve by 15% and read the Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Evaporator Fin Thermistor | Evaporator temperature sensor | Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | - |
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -0.4566 MPaG Max.: 3.2943 MPaG |
Actual refrigerant pressure displayed | - |
| Cooling Electric Expansion Valve Target Position | Electric expansion valve (cooling) | Min.: 0.00% Max.: 100.00% |
Electric expansion valve (cooling) target position displayed | - |
| Tester Display |
|---|
| Evaporator Fin Thermistor |
| Regulator Pressure Sensor |
| Cooling Electric Expansion Valve Target Position |
| OK |
|---|
| The value of Evaporator Fin Thermistor increases by 3°C (37°F). |
| Result | |||
|---|---|---|---|
|
| NG |
|
CHECK ELECTRIC EXPANSION VALVE (COOLING) Click here |
| OK |
|
READ VALUE USING GTS (EVAPORATOR FIN THERMISTOR)
According to the display on the GTS, decrease the value of Cooling Electric Expansion Valve by 15% and read the Data List.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Evaporator Fin Thermistor | Evaporator temperature sensor | Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | - |
| Tester Display |
|---|
| Evaporator Fin Thermistor |
| OK |
|---|
| The value of Evaporator Fin Thermistor decreases by 3°C (37°F). |
| Result | |||
|---|---|---|---|
|
| NG |
|
GO TO STEP 11 Click here |
| OK |
|
INSPECT NO. 1 AIR CONDITIONING ACCESSORY ASSEMBLY (ELECTRIC EXPANSION VALVE (HEATING))
Turn the power switch on (READY).
Push the AUTO switch to operate the air conditioning system.
Turn the power switch off and wait for 2 minutes.
Remove the No. 1 air conditioning accessory assembly (electric expansion valve (heating)).
Apply compressed air to the inlet port of the No. 1 air conditioning accessory assembly (electric expansion valve (heating)).
| OK |
|---|
| Air flows out of the outlet port. |
| Result | |||
|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (NO. 1 AIR CONDITIONING ACCESSORY ASSEMBLY (ELECTRIC EXPANSION VALVE (HEATING)) - HEAT PUMP ECU ASSEMBLY) Click here |
| OK |
|
INSPECT HIGH PRESSURE MAGNETIC VALVE
Remove the high pressure magnetic valve.
Inspect the high pressure magnetic valve.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE HIGH PRESSURE MAGNETIC VALVE Click here |
| OK |
|
HIGH PRESSURE MAGNETIC VALVE (POWER SOURCE CIRCUIT)
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| High Pressure Magnetic Valve | High pressure magnetic valve | OFF or ON | - |
| Tester Display |
|---|
| High Pressure Magnetic Valve |
| *a | Component without harness connected (High Pressure Magnetic Valve) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (HIGH PRESSURE MAGNETIC VALVE - HEAT PUMP ECU ASSEMBLY)
Disconnect the A42 heat pump ECU assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK VALVE TO CONNECTOR TUBE
Remove the valve to connector tube.
Apply compressed air to the inlet port and then outlet port of the valve to connector tube.
| OK |
|---|
| Air flows out of the outlet port when applied to the inlet port but not out of the inlet port when applied to the outlet port. |
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE MAIN COMPONENTS OF REFRIGERANT CYCLE |
| NG |
|
REPLACE VALVE TO CONNECTOR TUBE Click here |
CHECK HARNESS AND CONNECTOR (NO. 1 AIR CONDITIONING ACCESSORY ASSEMBLY (ELECTRIC EXPANSION VALVE (HEATING)) - HEAT PUMP ECU ASSEMBLY)
Disconnect the A42 heat pump ECU assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK NO. 1 AIR CONDITIONING ACCESSORY ASSEMBLY (ELECTRIC EXPANSION VALVE (HEATING))
| *a | Component without harness connected (No. 1 Air Conditioning Accessory Assembly (Electric Expansion Valve (Heating))) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| NG |
|
REPLACE NO. 1 AIR CONDITIONING ACCESSORY ASSEMBLY Click here |
CHECK ELECTRIC EXPANSION VALVE (COOLING)
Inspect the electric expansion valve (cooling).
| Result | |||
|---|---|---|---|
|
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| NG |
|
REPLACE ELECTRIC EXPANSION VALVE (COOLING) Click here |