PROCEDURE
INSTALL EVAPORATOR PIPE TEMPERATURE SENSOR
Install the evaporator pipe temperature sensor with the piping clamp.
Engage the claw.
Remove any remaining No. 2 cooler pipe packing from the evaporator pipe temperature sensor and suction tube sub-assembly.
Remove the release paper from a new No. 2 cooler pipe packing.
| *1 | Evaporator Pipe Temperature Sensor |
| *2 | Piping Clamp |
| *3 | No. 2 Cooler Pipe Packing |
| *4 | Suction Tube Sub-assembly |
| *a | View A |
| *b | Installation Angle (90°) |
Install the No. 2 cooler pipe packing as shown in the illustration.
for LHD:
Connect the connector.
Install a new wire harness clamp.
for RHD:
Connect the connector.
Engage the clamp.
INSTALL OUTER COWL TOP PANEL SUB-ASSEMBLY
INSTALL COWL BODY MOUNTING REINFORCEMENT LH
INSTALL WATER GUARD PLATE
INSTALL NO. 1 HEATER AIR DUCT SPLASH SHIELD SEAL (for LHD)
INSTALL NO. 2 HEATER AIR DUCT SPLASH SHIELD SEAL (for RHD)
INSTALL WINDSHIELD WIPER MOTOR AND LINK ASSEMBLY