| DTC Code | DTC Name |
|---|---|
| B14AD | Low Pressure Magnetic Valve Circuit |
DESCRIPTION
The low pressure magnetic valve is installed to the accumulator and accessory assembly and is open when the power switch is off. When the power switch is on (IG), the low pressure magnetic valve opens or closes according to the heat pump air-conditioning control. When the heat pump air-conditioning control is in cooling/series heating mode, the low pressure magnetic valve is closed based on the signal from the heat pump ECU assembly. When the heat pump air-conditioning control is in parallel heating/heating/gas injection heating mode, the low pressure magnetic valve is open.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B14AD | Low Pressure Magnetic Valve Circuit | Open or short in low pressure magnetic valve circuit |
|
Memorized (4 sec. or more)* |
*: The heat pump ECU assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Note
Inspect the fuses for circuits related to this system before performing the following procedure.
PROCEDURE
INSPECT HEAT PUMP ECU ASSEMBLY
| *a | Component without harness connected (Heat Pump ECU Assembly) |
Disconnect the A42 heat pump ECU assembly connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
INSPECT LOW PRESSURE MAGNETIC VALVE (POWER SOURCE CIRCUIT) Click here |
| OK |
|
INSPECT LOW PRESSURE MAGNETIC VALVE
| *a | Component without harness connected (Low Pressure Magnetic Valve) |
Remove the low pressure magnetic valve.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE HEAT PUMP ECU ASSEMBLY Click here |
| NG |
|
REPLACE LOW PRESSURE MAGNETIC VALVE Click here |
INSPECT LOW PRESSURE MAGNETIC VALVE (POWER SOURCE CIRCUIT)
| *a | Component without harness connected (Low Pressure Magnetic Valve) |
Disconnect the A44 low pressure magnetic valve connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (LOW PRESSURE MAGNETIC VALVE - HEAT PUMP ECU ASSEMBLY)
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE LOW PRESSURE MAGNETIC VALVE Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |