DATA LIST
Note
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Tech Tips
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus:
for Air Conditioner: Body Electrical / Air Conditioner / Data List.
for Main Body: Body Electrical / Main Body / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Room Temperature Sensor | Cooler (room temp. sensor) thermistor | Min.: -6.50°C (20.30°F) Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | - |
| Ambient Temp Sensor | Thermistor assembly | Min.: -23.30°C (-9.94°F) Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | - |
| Adjusted Ambient Temp | Adjusted ambient temperature | Min.: -30.80°C (-23.44°F) Max.: 50.80°C (123.44°F) |
- | - |
| Evaporator Fin Thermistor | Evaporator temperature sensor | Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | - |
| Evaporator Target Temp | Evaporator target temperature | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | - |
| Solar Sensor (D Side) | Driver side solar sensor*1 or solar sensor*2 | Min.: 0 Max.: 255 |
Driver side solar sensor*1 or solar sensor*2 value increases as brightness increases | - |
| Solar Sensor (P Side) | Front passenger side solar sensor | Min.: 0 Max.: 255 |
Front passenger side solar sensor value increases as brightness increases | *1 |
| Engine Coolant Temp | Engine coolant temperature sensor | Min.: 1.30°C (34.34°F) Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature displayed | - |
| Blower Motor Speed Level | Blower motor speed level | Min.: 0 Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor speed increases | - |
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -0.4566 MPaG Max.: 3.2943 MPaG |
Actual refrigerant pressure displayed | - |
| Air Outlet Servo Pulse (R) | No. 3 air conditioning radiator damper servo sub-assembly target pulse | Min.: 128 Max.: 383 |
|
- |
| Air Outlet Servo Actual Pls(R) | No. 3 air conditioning radiator damper servo sub-assembly actual pulse | Min.: 128 Max.: 383 |
|
- |
| Air Mix Servo Targ Pulse(D) | No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix*1 or air mix*2) target pulse | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
- |
| Air Mix Servo Actual Pulse(D) | No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix*1 or air mix*2) actual pulse | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
- |
| Air Mix Servo Targ Pulse(P) | No. 2 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
*1 |
| Air Mix Servo Actual Pulse(P) | No. 2 air conditioning radiator damper servo sub-assembly (front passenger side air mix) actual pulse | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
*1 |
| Air Outlet Servo Pulse (D) |
for LHD:
for RHD: |
Min.: 128 Max.: 383 |
for LHD:
for RHD: |
- |
| Air Outlet Servo Actu Pulse(D) |
for LHD:
for RHD: |
Min.: 128 Max.: 383 |
for LHD:
for RHD: |
- |
| Air Outlet Servo Targ Pulse(P) |
for LHD:
for RHD: |
Min.: 128 Max.: 383 |
for LHD:
for RHD: |
- |
| Air Outlet Servo Actu Pulse(P) |
for LHD:
for RHD: |
Min.: 128 Max.: 383 |
for LHD:
for RHD: |
- |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly target pulse | Min.: 128 Max.: 383 |
|
- |
| Air Inlet Damper Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse | Min.: 128 Max.: 383 |
|
- |
| Compressor Speed | Compressor speed | Min.: 0 rpm Max.: 65535 rpm |
Actual compressor speed displayed | - |
| Compressor Target Speed | Compressor target speed | Min.: 0 rpm Max.: 65535 rpm |
Compressor target speed displayed | - |
| Shift Set Temperature | Shift set temperature | 2C decr, 1C decr, Normal, 1C incr or 2C incr | Customized value displayed | - |
| Air Inlet Mode | Air inlet mode | Auto or Manual | Customized value displayed | *2 |
| Compressor Mode | Compressor mode | Auto or Manual | Customized value displayed | - |
| Noise and Vibration Reduction | Noise and vibration reduction | OFF or ON | Customized value displayed | - |
| ECO MODE Cancel | ECO drive mode cancel | OFF or ON | Customized value displayed | - |
| Refrigerant Shortage Check | Refrigerant shortage check | ON or OFF | Customized value displayed | - |
| Fan speed increment control | Fan speed increment control | Slow, Normal or Fast | Customized value displayed | - |
| Foot/DEF Auto Mode | Foot/defroster auto mode | ON or OFF | Customized value displayed | - |
| Foot/DEF Auto Blow Up | Foot/defroster auto blower speed increase | ON or OFF | Customized value displayed | - |
| Ambient Temperature Shift | Ambient temperature shift | 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr or 3C incr | Customized value displayed | - |
| Compressor Drive Check | Compressor drive check | OK or NG | OK: Compressor operates NG: Compressor does not operate |
- |
| Refrigerant Outlet Temperature | Discharge temperature sensor | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Actual refrigerant outlet temperature displayed | - |
| Glass Temperature | Windshield glass temperature | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Actual windshield glass temperature is displayed | - |
| Glass Surroundings Temperature | Temperature around windshield glass | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Actual temperature around windshield glass is displayed | - |
| Glass Humidity | Windshield glass humidity | Min.: 0.00% Max.: 100.00% |
Actual windshield glass humidity is displayed | - |
| Refrigerant Gas Type | Refrigerant gas type | R134a or 1234yf | Refrigerant gas type displayed | - |
| External Condenser Refrigerant Temperature Sensor | Heat exchanger temperature sensor | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Actual cooler condenser assembly refrigerant temperature displayed | - |
| Internal Condenser Refrigerant Temperature Sensor | Internal condenser temperature sensor | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Actual internal condenser refrigerant temperature displayed | - |
| Evaporator Refrigerant Temperature Sensor | Evaporator pipe temperature sensor | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Actual evaporator refrigerant temperature displayed | - |
| Middle Pressure Magnetic Valve Status | No. 1 air conditioning accessory assembly (middle pressure magnetic valve) | OFF or ON | No. 1 air conditioning accessory assembly (middle pressure magnetic valve) status displayed | - |
| Low Pressure Magnetic Valve Status | Low pressure magnetic valve | OFF or ON | Low pressure magnetic valve status displayed | - |
| High Pressure Magnetic Valve Status | High pressure magnetic valve | OFF or ON | High pressure magnetic valve status displayed | - |
| Cooling Electric Expansion Valve Target Position | Electric expansion valve (cooling) | Min.: 0.00% Max.: 100.00% |
Electric expansion valve (cooling) target position displayed | - |
| Heating Electric Expansion Valve Target Position | No. 1 air conditioning accessory assembly (electric expansion valve (heating)) | Min.: 0.00% Max.: 100.00% |
No. 1 air conditioning accessory assembly (electric expansion valve (heating)) target position displayed | - |
| Internal Condenser Target Temperature | Internal condenser target temperature | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Actual internal condenser target temperature displayed | - |
| Internal Condenser Estimated Temperature (ECU Calculation Value) | Internal condenser estimated temperature | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Estimated internal condenser temperature calculated by ECU | - |
| Subcool Target Temperature | Sub-cool target temperature | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Sub-cool target temperature calculated by ECU | - |
| Subcool Estimated Temperature (ECU Calculation Value) | Sub-cool estimated temperature | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Estimated sub-cool temperature calculated by ECU | - |
| Heat Pump Operating Cycle State | Heat pump operating cycle state | Cooling, Series Heating, Parallel Heating, Heating, Gas Injection Heating, Defrosting or Initialization | Heat pump operation cycle status | - |
| Set Temperature (D Side) | Driver side set temperature | Min.: MAX COLD Max.: MAX HOT |
Driver side set temperature displayed | - |
| Set Temperature (P Side) | Front passenger side set temperature | Min.: MAX COLD Max.: MAX HOT |
Front passenger side set temperature displayed | *1 |
| Outside Air Mode Auto Switch Function | Outside air mode auto switch function | ON or OFF | Customized value displayed | - |
| S-FLOW Control Auto Function | S-FLOW control auto function | ON or OFF | Customized value displayed | - |
| Communication Wiper ECU | Existence of function | With or Without | With: w/ Wiper ECU Without: w/o Wiper ECU |
- |
| Communication Wiper Switch | Existence of function | With or Without | With: w/ Wiper switch Without: w/o Wiper switch |
- |
| Communication Humidity/Rain Sensor | Existence of function | With or Without | With: w/ Humidity sensor Without: w/o Humidity sensor |
- |
| Remote Air Conditioner Start Setting | Remote air conditioner start setting | 1time ON, 2time ON, Long1, Long2 or OFF | Customized value displayed | - |
| Remote Air Conditioner Stop Setting | Remote air conditioner stop setting | 1time ON, 2time ON, Long1, Long2 or OFF | Customized value displayed | - |
| Number of Trouble Codes | Number of trouble codes | Min.: 0 Max.: 255 |
Number of DTCs displayed | - |
*1: for Dual Type
*2: for Single Type
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Hood Courtesy SW | Engine hood courtesy signal | OFF or ON | OFF: Engine food closed ON: Engine food open |
- |
ACTIVE TEST
Tech Tips
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower motor with fan sub-assembly | Min.: 0, Max.: 31 | - |
| Compressor Target Speed | Compressor with motor assembly | Min.: 0, Max.: 7500 | - |
| Defogger Relay (Rear) | Rear window defogger | OFF or ON | - |
| Electrical Fan | Control electric cooling fan motor | OFF or ON | Perform this test when the following conditions are met:
|
| Air Mix Servo Targ Pulse(D) | No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix*1 or air mix*2) pulse | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
| Air Mix Servo Targ Pulse(P) | No. 2 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse*1 | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
| Air Outlet Servo Pulse (D) |
for LHD:
for RHD: |
Min.: 128 Max.: 383 |
for LHD:
for RHD: |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly pulse | Min.: 128 Max.: 383 |
Operates between 220 to 256 pulses |
| Air Outlet Servo Pulse (P) |
for LHD:
for RHD: |
Min.: 128 Max.: 383 |
for LHD:
for RHD: |
| A/O Servo Pulse(Rr D) | No. 3 air conditioning radiator damper servo sub-assembly pulse | Min.: 128 Max.: 383 |
Operates between 250 to 297 pulses |
| Heating Electric Expansion Valve | No. 1 air conditioning accessory assembly (electric expansion valve (heating)) | Min.: 0% Max.: 100% |
Perform this test with the following conditions met:
|
| Cooling Electric Expansion Valve | Electric expansion valve (cooling) | Min.: 0% Max.: 100% |
Perform this test with the following conditions met:
|
| High Pressure Magnetic Valve | High pressure magnetic valve | OFF or ON | - |
| Middle Pressure Magnetic Valve | No. 1 air conditioning accessory assembly (middle pressure magnetic valve) | OFF or ON | - |
| Low Pressure Magnetic Valve | Low pressure magnetic valve | OFF or ON | - |
*1: for Dual Type
*2: for Single Type