REFRIGERANT SHORTAGE CHECK IN NORMAL OPERATION (CHECK A/C SWITCH INDICATOR AND DTC)
Turn the power switch on (READY).
Check that the A/C switch indicator remains on when the following conditions are met.
| *A | for LHD (for Dual Type) | *B | for RHD |
| *C | for LHD (for Single Type) | - | - |
| Item | Condition |
|---|---|
| A/C switch | On |
| A/C operation time | 5 minutes or more |
| Ambient temperature* | 12 to 34°C (54 to 93°F) |
| Temperature setting | MAX COLD |
| Recirculation/fresh switch | FRESH |
| Blower speed | HI |
*: If the ambient temperature is not within the range shown, do not perform this check.
Tech Tips
The A/C switch indicator and air conditioning system turn off if the amount of refrigerant in the system is insufficient.
Connect the GTS to the DLC3.
Check for DTC B14B8.