| DTC Code | DTC Name |
|---|---|
| B1381 | Internal Condenser Refrigerant Temperature Sensor Circuit |
DESCRIPTION
The internal condenser temperature sensor is installed to the outlet pipe of the No. 2 condenser assembly and detects the refrigerant temperature for heat pump air-conditioning control. The resistance of the internal condenser temperature sensor changes depending on the refrigerant temperature of the No. 2 condenser assembly outlet. When the temperature becomes low, the resistance of the thermistor increases. When the temperature becomes high, the resistance decreases.
The heat pump ECU assembly applies a voltage (5 V) to the internal condenser temperature sensor and reads voltage changes due to changes in the resistance of the internal condenser temperature sensor.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1381 | Internal Condenser Refrigerant Temperature Sensor Circuit | Open or short in internal condenser temperature sensor circuit |
|
Memorized (4 sec. or more)* |
*: The heat pump ECU assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
WIRING DIAGRAM
| *a | TPL |
| *b | TFG |
| *c | Internal Condenser Temperature Sensor |
| *d | Heat Pump ECU Assembly |
PROCEDURE
CHECK FOR DTC
Check for DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
CHECK HARNESS AND CONNECTOR (INTERNAL CONDENSER TEMPERATURE SENSOR - HEAT PUMP ECU ASSEMBLY) Click here |
| A |
|
INSPECT INTERNAL CONDENSER TEMPERATURE SENSOR
| *a | Component without harness connected (Internal Condenser Temperature Sensor) |
| *b | Sensing Portion |
| *c | Resistance (kΩ) |
| *d | Temperature (°C (°F)) |
| *e | Allowable Range |
Remove the internal condenser temperature sensor.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
Tech Tips
As the temperature increases, the resistance decreases (see the graph).
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE INTERNAL CONDENSER TEMPERATURE SENSOR Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (INTERNAL CONDENSER TEMPERATURE SENSOR - HEAT PUMP ECU ASSEMBLY)
Disconnect the A42 heat pump ECU assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE HEAT PUMP ECU ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
CHECK HARNESS AND CONNECTOR (INTERNAL CONDENSER TEMPERATURE SENSOR - HEAT PUMP ECU ASSEMBLY)
Disconnect the I71 internal condenser temperature sensor connector.
Disconnect the A42 heat pump ECU assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE HEAT PUMP ECU ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |