| DTC No. | Detection Item | Warning Indicate | Link |
|---|---|---|---|
| P1EA412 | Solar Charging Voltage Sensor Circuit Short to Auxiliary Battery | Solar Charging Warning Light: Comes on |
|
| P1EA414 | Solar Charging Voltage Sensor Circuit Short to Ground or Open | Solar Charging Warning Light: Comes on |
|
| P1EAB11 | Solar Charging Battery Temperature Sensor 1 Circuit Short to Ground | Solar Charging Warning Light: Comes on |
|
| P1EAB15 | Solar Charging Battery Temperature Sensor 1 Circuit Short to Auxiliary Battery or Open | Solar Charging Warning Light: Comes on |
|
| P1EB011 | Solar Charging Battery Temperature Sensor 2 Circuit Short to Ground | Solar Charging Warning Light: Comes on |
|
| P1EB015 | Solar Charging Battery Temperature Sensor 2 Circuit Short to Auxiliary Battery or Open | Solar Charging Warning Light: Comes on |
|
| P1EB511 | Solar Charging Battery Temperature Sensor 3 Circuit Short to Ground | Solar Charging Warning Light: Comes on |
|
| P1EB515 | Solar Charging Battery Temperature Sensor 3 Circuit Short to Auxiliary Battery or Open | Solar Charging Warning Light: Comes on |
|
| P1EBA17 | Solar Charging Voltage Circuit Voltage Above Threshold | Solar Charging Warning Light: Comes on |
|
| P1EC000 | Solar Charging Battery Block 1 Circuit Resistance Out of Range (Extreme) | Solar Charging Warning Light: Comes on |
|
| P1EC01E | Solar Charging Battery Block 1 Circuit Resistance Out of Range | Solar Charging Warning Light: Comes on |
|
| P1EC11E | Solar Charging Battery Block 1 Voltage Difference Out of Range | Solar Charging Warning Light: Comes on |
|
| P1EC200 | Solar Charging Battery Block 2 Circuit Resistance Out of Range (Extreme) | Solar Charging Warning Light: Comes on |
|
| P1EC21E | Solar Charging Battery Block 2 Circuit Resistance Out of Range | Solar Charging Warning Light: Comes on |
|
| P1EC31E | Solar Charging Battery Block 2 Voltage Difference Out of Range | Solar Charging Warning Light: Comes on |
|
| P1EC400 | Solar Charging Battery Block 3 Circuit Resistance Out of Range (Extreme) | Solar Charging Warning Light: Comes on |
|
| P1EC41E | Solar Charging Battery Block 3 Circuit Resistance Out of Range | Solar Charging Warning Light: Comes on |
|
| P1EC51E | Solar Charging Battery Block 3 Voltage Difference Out of Range | Solar Charging Warning Light: Comes on |
|
| P1EC600 | Solar Charging Battery Stack 1 Delta SOC High | Solar Charging Warning Light: Comes on |
|
| P1EC700 | Solar Charging Battery Cell Low Voltage | Solar Charging Warning Light: Comes on |
|
| P1EC81B | Solar Charging Battery Block Circuit Resistance Above Threshold | Solar Charging Warning Light: Comes on |
|
| P1ECC00 | Solar Charging Battery State of Charge High | Solar Charging Warning Light: Comes on |
|
| P1ECD00 | Solar Charging Battery Discharge Control Malfunction | Solar Charging Warning Light: Comes on |
|
| P1ECD16 | Solar Charging Battery Control System Circuit Voltage Below Threshold | Solar Charging Warning Light: Comes on |
|
| P1ECD4B | Solar Charging Battery Control System Over Temperature | Solar Charging Warning Light: Comes on |
|
| P1ECE49 | Solar Charging Battery Control System Internal Electronic Failure | Solar Charging Warning Light: Comes on |
|
| P1ECF49 | Internal Control Module Solar Charger Battery Monitor A/D Processing Internal Electronic Failure | Solar Charging Warning Light: Comes on |
|
| P1ECF87 | Lost Communication with Internal Control Module Solar Charger Battery Monitor Missing Message | Solar Charging Warning Light: Comes on |
|
| P1ED000 | Solar Charging Battery Charging Current Unbalance | Solar Charging Warning Light: Comes on |
|
| P1ED196 | Solar Charge Auxiliary Battery DC/DC Converter Component Internal Failure | Solar Charging Warning Light: Comes on |
|
| P1ED228 | Solar Charging Battery Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | Solar Charging Warning Light: Comes on |
|
| P1ED362 | Solar Charging Battery Temperature Sensor Signal Compare Failure | Solar Charging Warning Light: Comes on |
|
| P1ED462 | Solar Charging Battery Voltage Sensor Signal Compare Failure | Solar Charging Warning Light: Comes on |
|
| P1ED516 | Solar Charging Battery Voltage Sensor Circuit Voltage Below Threshold | Solar Charging Warning Light: Comes on |
|
| P1ED517 | Solar Charging Battery Voltage Sensor Circuit Voltage Above Threshold | Solar Charging Warning Light: Comes on |
|
| P1EDB49 | Solar Charger Control Module A/D Processing Internal Electronic Failure | Solar Charging Warning Light: Comes on |
|
| P1EDC96 | Solar Charge Hybrid Battery DC/DC Converter Component Internal Failure | Solar Charging Warning Light: Comes on |
|
| P1EDD13 | Solar Charging Battery Voltage Sensor "A" Circuit Open | Solar Charging Warning Light: Comes on |
|
| P1EE213 | Solar Charging Battery Voltage Sensor "B" Circuit Open | Solar Charging Warning Light: Comes on |
|
| P1EE713 | Solar Charging Battery Voltage Sensor "C" Circuit Open | Solar Charging Warning Light: Comes on |
|
| U010087 | Lost Communication With ECM/PCM "A" Missing Message | Solar Charging Warning Light: Does not come on |
|
| U011187 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message | Solar Charging Warning Light: Comes on |
|
| U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message | Solar Charging Warning Light: Does not come on |
|
| U115087 | Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message | Solar Charging Warning Light: Comes on |