DATA LIST
Note
The value of some Data List items may vary significantly if there are slight differences in the environment in which the vehicle is operating when the Data List is read. Variations may also occur due to the age of the vehicle.
In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under identical conditions in order to reach an overall judgment by comparing all the items in the Data List.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Solar Charging Control / Data List.
Check the results by referring to the following table.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Total Distance Traveled | Total distance driven | Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile) | - | - |
| ACC Status | ACC terminal status | ON or OFF | - | ACC terminal |
| IG ON Status | Power switch on (IG) | ON or OFF | - | - |
| IGCT Status | IGCT terminal status | ON or OFF | - | IGCT terminal |
| Hybrid Battery Charging Permission Status | Hybrid battery charging permission status | None / OK / NG by Solar Charging system / NG by Hybrid Control System / NG by Hybrid Battery / Temporarily NG by Hybrid Battery | - | - |
| Hybrid Battery Charging Status after Solar Charging Battery Charging Complete | Hybrid battery charging control state after solar battery charged | None / Charge Waiting / Charging / Process to Stop / Discharge Waiting | - | - |
| Hybrid Battery Voltage | Hybrid battery voltage | Min.: 0.0 V, Max.: 6553.5 V | 0 to 380V | DCHB terminal (When CHR relay closed) |
| Hybrid Battery Voltage Sensor Voltage | Hybrid battery voltage sensor voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charging Battery Charging and Discharging Voltage | Solar battery charging and discharging voltage | Min.: 0.0 V, Max.: 79.99 V | 18 to 30 V | VBS terminal |
| Solar Charging Battery Charging and Discharging Voltage Sensor Voltage | Solar battery charging and discharging sensor voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charging Battery SOC | SOC of solar battery | Min.: 0.0%, Max.: 6553.5% | 20 to 80% | - |
| Solar Charging Battery Delta SOC | Difference between maximum and minimum values of SOC | Min.: 0.0%, Max.: 127.5% | Below 20% | - |
| Solar Charging Battery Current | Solar battery current | Min.: -327.68 A, Max.: 327.67 A | -15 to 25 A | |
| Solar Charging Battery Input Power | Solar battery input power | Min.: -327.68 kW, Max.: 327.67 kW | - | - |
| Solar Charging Battery Output Power | Solar battery output power | Min.: -327.68 kW, Max.: 327.67 kW | - | - |
| Solar Charging Battery Block 1 Temperature | Solar charging battery block 1 temperature | Min.: -50°C (-58°F), Max.: 205.9°C (402.62°F) | -30°C (-22°F)) to 60°C (140°F) | - |
| Solar Charging Battery Block 2 Temperature | Solar charging battery block 2 temperature | Min.: -50°C (-58°F), Max.: 205.9°C (402.62°F) | -30°C (-22°F)) to 60°C (140°F) | - |
| Solar Charging Battery Block 3 Temperature | Solar charging battery block 3 temperature | Min.: -50°C (-58°F), Max.: 205.9°C (402.62°F) | -30°C (-22°F)) to 60°C (140°F) | - |
| Solar Charging Battery Block 1 Temperature Sensor Voltage | Solar battery temperature sensor 1 voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charging Battery Block 2 Temperature Sensor Voltage | Solar battery temperature sensor 2 voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charging Battery Block 3 Temperature Sensor Voltage | Solar battery temperature sensor 3 voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charging Battery Block 1 Cell Average Voltage | Solar Charging Battery Block 1 Cell Average Voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charging Battery Block 2 Cell Average Voltage | Solar Charging Battery Block 2 Cell Average Voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charging Battery Block 3 Cell Average Voltage | Solar Charging Battery Block 3 Cell Average Voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charging Battery Block Total Voltage | Solar battery block total voltage | Min.: 0.0 V, Max.: 6553.5 V | 18 to 30 V | - |
| Solar Charging Battery Block 1 Voltage | Solar battery block 1 voltage | Min.: 0.0 V, Max.: 79.99 V | 6.0 to 10.0 V | - |
| Solar Charging Battery Block 2 Voltage | Solar battery block 2 voltage | Min.: 0.0 V, Max.: 79.99 V | 6.0 to 10.0 V | - |
| Solar Charging Battery Block 3 Voltage | Solar battery block 3 voltage | Min.: 0.0 V, Max.: 79.99 V | 6.0 to 10.0 V | - |
| Solar Charging Battery Block 1 Voltage Sensor Upper Side Voltage | Solar battery block 1 voltage sensor upper side voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charging Battery Block 1 Voltage Sensor Under Side Voltage | Solar battery block 1 voltage sensor under side voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charging Battery Block 2 Voltage Sensor Upper Side Voltage | Solar battery block 2 voltage sensor upper side voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charging Battery Block 2 Voltage Sensor Middle Side Voltage | Solar battery block 2 voltage sensor middle side voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charging Battery Block 2 Voltage Sensor Under Side Voltage | Solar battery block 2 voltage sensor under side voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charging Battery Block 3 Voltage Sensor Upper Side Voltage | Solar battery block 3 voltage sensor upper side voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charging Battery Block 3 Voltage Sensor Under Side Voltage | Solar battery block 3 voltage sensor under side voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charging Battery Block 1 Internal Resistance | Solar battery block 1 internal resistance | Min.: 0.0 ohm, Max.: 0.255 ohm | 0.010 to 0.100 ohm | - |
| Solar Charging Battery Block 2 Internal Resistance | Solar battery block 2 internal resistance | Min.: 0.0 ohm, Max.: 0.255 ohm | 0.010 to 0.100 ohm | - |
| Solar Charging Battery Block 3 Internal Resistance | Solar battery block 3 internal resistance | Min.: 0.0 ohm, Max.: 0.255 ohm | 0.010 to 0.100 ohm | - |
| Solar Charging Battery Relay Status | Solar battery relay status | ON or OFF | - | - |
| Solar Charging System Status | Solar charging system status | Waiting Mode / Fail Safe Mode / Solar Charging Battery Charging Mode / Auxiliary Battery Charging Mode / Hybrid Battery Charging Mode / Sleep Mode / Reprogramming Mode / DC/DC Converter Start Check Mode / VBS Open Circuit Detection Mode | - | Wait Mode: Charging and discharging prohibited by battery control Fail Safe Mode: Charging and discharging prohibited by battery control Solar Charging Battery Charging Mode: Only solar battery being charged Auxiliary Battery Charging Mode: Power being supplied to accessories and auxiliary battery Hybrid Battery Charging Mode: HV battery being charged Sleep Mode: Solar energy control unit in sleep mode Reprogramming Mode: Reprogramming being performed DC/DC Converter Start Check Mode: Initial check of DC/DC converter being performed VBS Open Circuit Detection Mode: Electricity conversion being suspended to check for open in VBS circuit |
| Solar Charging Control ECU System Voltage | Solar charging energy control unit system voltage | Min.: 0.0 V, Max.: 79.99 V | 8 to 55 V | Highest voltage of any of the following:
|
| Solar Charging Permission | Solar charging permission state | NG or OK | - | - |
| Solar Charging Battery Charging Permission from Auxiliary Battery | Solar charging battery charging permission from auxiliary battery | ON or OFF | - | ON: The value of this item is ON when the SOC of the solar battery is extremely low and supplemental charging is necessary, and OFF in all other situations. |
| Auxiliary Battery Charging Permission to Auxiliary Battery | Auxiliary battery charging permission to auxiliary battery | ON or OFF | - | - |
| Solar Charging Control ECU Temperature | Temperature inside solar charging control ECU | Min.: -50°C (-58°F), Max.: 205.9°C (402.62°F) | Vehicle left in a dark area for 1 day: Same as ambient air temperature |
- |
| Solar Panel Output Voltage | Solar panel output voltage | Min.: 0.0 V, Max.: 79.99 V | 0 to 55 V | VSOP terminal |
| Solar Panel Output Voltage Sensor Voltage | Solar panel output voltage sensor voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charge Auxiliary Battery DC/DC Converter Drive Request | Solar charge auxiliary battery DC/DC converter drive request | ON or OFF | - | - |
| Stepped Down Voltage by Solar Charge Auxiliary Battery DC/DC Converter | Stepped down voltage from auxiliary battery DC/DC converter | Min.: 0.0 V, Max.: 79.99 V | 0 to 16 V | - |
| Stepped Down Voltage by Solar Charge Auxiliary Battery DC/DC Converter Sensor Voltage | Stepped down voltage from auxiliary battery DC/DC converter sensor voltage | Min.: 0.0 V, Max.: 4.99 V | - | - |
| Solar Charge Auxiliary Battery DC/DC Converter Output Power | Auxiliary battery DC/DC converter output power | Min.: 0.0 W, Max.: 65535.0 W | 0 to 150 W | - |
| Solar Charge Hybrid Battery DC/DC Converter Drive Request | Hybrid battery DC/DC converter drive request | ON or OFF | - | - |
| Solar Charge Hybrid Battery DC/DC Converter Input Voltage | Hybrid battery DC/DC converter input voltage | Min.: 0.0 V, Max.: 79.99 V | 0 to 30 V | - |
| Solar Charge Hybrid Battery DC/DC Converter Input Power | Hybrid battery DC/DC converter input power | Min.: 0.0 W, Max.: 65535.0 W | 120 to 180 W | - |
| Solar Charge Solar Charging Battery DC/DC Converter Drive Request | Solar battery DC/DC converter drive request | ON or OFF | - | - |
| Solar Charge Solar Charging Battery DC/DC Converter Input Current | Solar battery DC/DC converter input current | Min.: -32.768 A, Max.: 32.767 A | 0 to 10 A | - |
| Solar Charge Solar Charging Battery DC/DC Converter Input Power | Solar battery DC/DC converter input power | Min.: 0.0 W, Max.: 65535.0 W | 0 to 180 W | - |
| Solar Charge Solar Charging Battery DC/DC Converter Output Power | Solar battery DC/DC converter output power | Min.: 0.0 W, Max.: 65535.0 W | 0 to 180 W | - |