CHARGING SYSTEM TERMINALS OF ECU


  1. B006HDFC08
    *1 Hybrid Vehicle Control ECU - -

    Tech Tips

    The standard normal voltage between each pair of hybrid vehicle control ECU terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the hybrid vehicle control ECU terminal locations.

    Hybrid Vehicle Control ECU
    Terminal No. (Symbol) Wiring Color Input/Output Terminal Description Condition Specified Condition
    A41-4 (HMCH) - I3-3 (E1) B - W-B IN/OUT CAN Communication signal Power switch on (IG)

    Pulse generation

    (Waveform 1)

    I2-32 (MRL2) - I3-3 (E1) BE - W-B OUT IGCT relay Power switch on (IG) 11 to 14 V
    A41-8 (LIN3) - I3-3 (E1) G - W-B IN/OUT LIN communication signal Power switch on (READY) Pulse generation
    A41-14 (HMCL) - I3-3 (E1) W - W-B IN/OUT CAN Communication signal Power switch on (IG)

    Pulse generation

    (Waveform 1)


    1. Oscilloscope waveforms

      Tech Tips

      Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


      1. B006HBPE06

        Waveform 1 (CAN communication signal)

        Item Content
        Terminal

        CH1: A41-14 (HMCL) - I3-3 (E1)

        CH2: A41-4 (HMCH) - I3-3 (E1)

        Equipment Setting 1 V/DIV., 50 μs./DIV.
        Condition Power switch on (IG)

        Tech Tips

        The waveform will vary depending on the content of the digital communication (digital signal).