SERVICE PLUG GRIP INSTALLATION

PROCEDURE


  1. INSTALL SERVICE PLUG GRIP

    CAUTION:

    Wear insulated gloves.

    Note

    Before installing the service plug grip, check that no parts or tools remain and that the high voltage terminals and connectors are connected securely.


    1. While wearing insulated gloves, and temporarily install the service plug grip as indicated by the arrow (1) shown in the illustration.

      A003MSON01
    2. Rotate the handle of the service plug grip 90° toward the HV battery and slide it in the direction indicated by the arrow (3) shown in the illustration until a click sound is heard to install the service plug grip.

  2. INSTALL NO. 4 HV BATTERY SHIELD PANEL


    1. Install the No. 4 HV battery shield panel to the HV battery with the 4 nuts.

      Torque:
      7.5 N*m  { 76 kgf*cm, 66 in.*lbf }
  3. INSTALL REAR NO. 1 FLOOR BOARD

    Click here

  4. INSTALL REAR NO. 2 FLOOR BOARD

    Click here

  5. CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here