PROCEDURE
CHECK DTC OUTPUT (HEALTH CHECK)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Health Check.
Check DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
GO TO DTC CHART |
| A |
|
CHECK FOR VEHICLE CONTROL HISTORY
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Plug-in Control / Utility / Vehicle Control History.
| Tester Display |
|---|
| Vehicle Control History (RoB) |
Enter the following menus: Powertrain / Hybrid Control / Utility / Vehicle Control History.
| Tester Display |
|---|
| Vehicle Control History (RoB) |
Check for Vehicle Control History.
Tech Tips
If plug-in charging has not started, Vehicle Control History will not be stored.
(Except if a power outage occurred before plug-in charging could start.)
If Vehicle Control History has been stored, it can be determined that plug-in charging has been performed.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
GO TO VEHICLE CONTROL HISTORY PLUG-IN CHARGE CONTROL SYSTEM Click here HYBRID CONTROL SYSTEM Click here |
| A |
|
CHECK PLUG-IN CHARGE STATE (USING A KNOWN GOOD ELECTRIC VEHICLE CHARGER CABLE ASSEMBLY)
Note
Make sure to use a known good AC power source.
Make sure to use a known good electric vehicle charger cable assembly.
Use the same 110 to 240 V power that the customer used to plug-in charge the vehicle.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Health Check.
Clear DTCs.
Enter the following menus: Powertrain / Plug-in Control / Utility / Vehicle Control History.
| Tester Display |
|---|
| Vehicle Control History (RoB) |
Clear all Vehicle Control History items.
Enter the following menus: Powertrain / Hybrid Control / Utility / Vehicle Control History.
| Tester Display |
|---|
| Vehicle Control History (RoB) |
Clear all Vehicle Control History items.
Enter the following menus: Powertrain / Hybrid Control / Data List / Hybrid Battery SOC.
| Tester Display |
|---|
| Hybrid Battery SOC |
According to the display on the GTS, read the Data List and confirm that the SOC of the HV battery is less than 70%.
Tech Tips
If the SOC of the HV battery is 70% or more, drive the vehicle in EV mode to discharge the HV battery until the SOC becomes less than 70%.
| Tester Display | Measurement Item | Range | Normal Condition |
|---|---|---|---|
| Hybrid Battery SOC | Hybrid Battery SOC | 0.00 to 100.00% | 0.00 to 100.00%: Always |
Turn the Charge Now on.
Tech Tips
If no charge schedule has been registered, the above step is not necessary.
Setting Charge Now to ON:
- Push the timer charging switch (fuel control switch).
- Using the steering pad switches, select "Charge Now" on the Timer Charging Charge Schedule screen of the multi-information display.
Plug-in charge the vehicle using a known good electric vehicle charger cable assembly.
Enter the following menus: Health Check.
Check DTCs.
Enter the following menus: Powertrain / Plug-in Control / Utility / Vehicle Control History.
| Tester Display |
|---|
| Vehicle Control History (RoB) |
Enter the following menus: Powertrain / Hybrid Control / Utility / Vehicle Control History.
| Tester Display |
|---|
| Vehicle Control History (RoB) |
Check for Vehicle Control History.
Turn the power switch off.
Disconnect the electric vehicle charger cable assembly.
| Result | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| A |
|
GO TO DTC CHART |
| B |
|
GO TO VEHICLE CONTROL HISTORY PLUG-IN CHARGE CONTROL SYSTEM Click here HYBRID CONTROL SYSTEM Click here |
| D |
|
GO TO ELECTRIC VEHICLE CHARGER CABLE ASSEMBLY INSPECTION Click here |
| E |
|
Analyze the cause according to the following table. Inspect auxiliary battery Click here Control pilot signal circuit Click here Take appropriate action in accordance with the result of the cause analysis. |
| F |
|
CAUSE ANALYSIS (ENVIRONMENT/USER RELATED CAUSE) Perform cause analysis in the order of "Environment" and "User" categories as specified in the following tables. Interview customer and provide instruction on usage. Click here Explain to the customer that the plug-in charging was suspended due to power outage, circuit breaker operation, etc. Interview customer and check the charging station. Click here Explain to the customer that plug-in charging may not start due to a power management function or charging control function of the charging station. Also, charging may not be performed if the charging station is incompatible. (Check the charging station specifications provided by the manufacturer.) Explain to the customer that depending on the specifications of the charging station, plug-in charging may be suspended when HV battery cooling system is being operated. Interview customer and provide instruction on usage. Click here Explain to the customer that if the charging connector is connected when the timer charging is set, the charging indicator (EV charger lid indicator assembly) will blink for a few seconds and then turn off. Explain to the customer that plug-in charging will not start immediately after connecting the charging cable if the timer charging is set. (Explain to the customer that plug-in charging can be started immediately if all of the charge schedules are canceled or if Charge Now is turned on.) Explain to the customer that if they want to perform charging immediately, if a scheduled charging time is set, they must select "Charge Now" on the Timer Charging Charge Schedule screen of the multi-information display. Interview customer and provide instruction on usage. Click here Explain to the customer that the charging connector should be fully inserted into the charger inlet. Explain to the customer that if the charging connector is connected to the vehicle when the HV battery is fully charged, the charging indicator (EV charger lid indicator assembly) will illuminate (Charge Now) or blink (timer charging) for several seconds and then turn off and plug-in charging will not start. Explain to the customer that if the charging connector is connected to the vehicle when the HV battery is fully charged, all 3 of the SOC indicators (indicator light assembly) will blink for a few seconds to inform the user that the HV battery is fully charged. Take appropriate action in accordance with the result of the cause analysis. |
| C |
|
CHECK PLUG-IN CHARGE STATE (USING THE ELECTRIC VEHICLE CHARGER CABLE ASSEMBLY PROVIDED WITH THE VEHICLE (W/ CCID))
Note
Make sure to use a known good AC power source.
Plug-in charge the vehicle using the electric vehicle charger cable assembly provided with the vehicle.
Use the same 110 to 240 V power that the customer used to plug-in charge the vehicle.
Perform plug-in charging using the electric vehicle charger cable assembly that was provided with the vehicle (w/ CCID) until the HV battery is fully charged.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Plug-in Control / Utility / Vehicle Control History.
| Tester Display |
|---|
| Vehicle Control History (RoB) |
Enter the following menus: Powertrain / Hybrid Control / Utility / Vehicle Control History.
| Tester Display |
|---|
| Vehicle Control History (RoB) |
Check for Vehicle Control History.
Disconnect the electric vehicle charger cable assembly.
Turn the power switch off.
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| A |
|
GO TO VEHICLE CONTROL HISTORY PLUG-IN CHARGE CONTROL SYSTEM Click here HYBRID CONTROL SYSTEM Click here |
| B |
|
Analyze the cause according to the following table. Inspect auxiliary battery Click here Control pilot signal circuit Click here Inspect electric vehicle charger cable assembly Click here |
| C |
|
CAUSE ANALYSIS (ENVIRONMENT/USER RELATED CAUSE) Perform cause analysis in the order of "Environment" and "User" categories as specified in the following tables. Interview customer and provide instruction on usage. Click here Explain to the customer that the plug-in charging was suspended due to power outage, circuit breaker operation, etc. Interview customer and check the charging station. Click here Explain to the customer that plug-in charging may not start due to a power management function or charging control function of the charging station. Also, charging may not be performed if the charging station is incompatible. (Check the charging station specifications provided by the manufacturer.) Explain to the customer that depending on the specifications of the charging station, plug-in charging may be suspended when HV battery cooling system is being operated. Interview customer and provide instruction on usage. Click here Explain to the customer that if the charging connector is connected when the timer charging is set, the charging indicator (EV charger lid indicator assembly) will blink for a few seconds and then turn off. Explain to the customer that plug-in charging will not start immediately after connecting the charging cable if the timer charging is set. (Explain to the customer that plug-in charging can be started immediately if all of the charge schedules are canceled or if Charge Now is turned on.) Explain to the customer that if they want to perform charging immediately, if a scheduled charging time is set, they must select "Charge Now" on the Timer Charging Charge Schedule screen of the multi-information display. Interview customer and provide instruction on usage. Click here Explain to the customer that the charging connector should be fully inserted into the charger inlet. Explain to the customer that if the charging connector is connected to the vehicle when the HV battery is fully charged, the charging indicator (EV charger lid indicator assembly) will illuminate (Charge Now) or blink (timer charging) for several seconds and then turn off and plug-in charging will not start. Explain to the customer that if the charging connector is connected to the vehicle when the HV battery is fully charged, all 3 of the SOC indicators (indicator light assembly) will blink for a few seconds to inform the user that the HV battery is fully charged. Take appropriate action in accordance with the result of the cause analysis. |