| DTC No. | Detection Item | MIL | Warning Indicate | Link |
|---|---|---|---|---|
| P060649 | Plug-in Control Module Internal Electronic Failure | Does not come on | Master Warning Light: Comes on |
|
| P060B49 | Plug-in Control Module A/D Processing Internal Electronic Failure | Comes on | Master Warning Light: Comes on |
|
| P062F44 | Plug-in Control Module EEPROM Data Memory Failure | Comes on | Master Warning Light: Does not come on |
|
| P0D2A19 | Hybrid/EV Battery Charger Input Current Sensor Circuit Circuit Current Above Threshold | Comes on | Master Warning Light: Comes on |
|
| P0D3812 | Hybrid/EV Battery Charger Input Current Sensor Circuit Circuit Short to Auxiliary Battery | Comes on | Master Warning Light: Comes on |
|
| P0D3814 | Hybrid/EV Battery Charger Input Current Sensor Circuit Circuit Short to Ground or Open | Comes on | Master Warning Light: Comes on |
|
| P0D3828 | Hybrid/EV Battery Charger Input Current Sensor Circuit Signal Bias Level Out of Range / Zero Adjustment Failure | Comes on | Master Warning Light: Comes on |
|
| P0D389E | Hybrid/EV Battery Charger Input Current Sensor Overcurrent Detection Circuit Stuck On | Comes on | Master Warning Light: Comes on |
|
| P0D3D16 | Hybrid/EV Battery Charger Input Voltage Sensor for Control Circuit Voltage Below Threshold | Comes on | Master Warning Light: Comes on |
|
| P0D3D17 | Hybrid/EV Battery Charger Input Voltage Sensor for Control Circuit Voltage Above Threshold | Comes on | Master Warning Light: Comes on |
|
| P0D4C12 | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Short to Auxiliary Battery | Comes on | Master Warning Light: Comes on |
|
| P0D4C14 | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Short to Ground or Open | Comes on | Master Warning Light: Comes on |
|
| P0D5611 | Charging Connector Proximity Detection Circuit Short to Ground | Comes on | Master Warning Light: Comes on |
|
| P0D5615 | Charging Connector Proximity Detection Circuit Short to Auxiliary Battery or Open | Comes on | Master Warning Light: Comes on |
|
| P0D5C00 | Charger Input/Output Power Difference High | Does not come on | Master Warning Light: Comes on |
|
| P0E5E49 | Hybrid/EV Battery Charger Control Module Internal Electronic Failure | Does not come on | Master Warning Light: Comes on |
|
| P0E5E87 | Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message | Comes on | Master Warning Light: Comes on |
|
| P1C0012 | Voltage Sensor after Boosting by PFC Boosting Circuit Circuit Short to Auxiliary Battery | Comes on | Master Warning Light: Comes on |
|
| P1C0014 | Voltage Sensor after Boosting by PFC Boosting Circuit Circuit Short to Ground or Open | Comes on | Master Warning Light: Comes on |
|
| P1C0016 | Voltage Sensor after Boosting by PFC Boosting Circuit Circuit Voltage Below Threshold | Comes on | Master Warning Light: Comes on |
|
| P1C009E | Voltage Sensor after Boosting by PFC Boosting Circuit Overvoltage Detection Circuit Stuck On | Comes on | Master Warning Light: Comes on |
|
| P1C0512 | PFC Inverter Temperature Sensor Circuit Short to Auxiliary Battery | Does not come on | Master Warning Light: Comes on |
|
| P1C0514 | PFC Inverter Temperature Sensor Circuit Short to Ground or Open | Does not come on | Master Warning Light: Comes on |
|
| P1C0A12 | DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery | Does not come on | Master Warning Light: Comes on |
|
| P1C0A14 | DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open | Does not come on | Master Warning Light: Comes on |
|
| P1C1012 | Current after Boosting by PFC Boosting Circuit Circuit Short to Auxiliary Battery | Comes on | Master Warning Light: Comes on |
|
| P1C1014 | Current after Boosting by PFC Boosting Circuit Circuit Short to Ground or Open | Comes on | Master Warning Light: Comes on |
|
| P1C1028 | Current after Boosting by PFC Boosting Circuit Signal Bias Level Out of Range / Zero Adjustment Failure | Comes on | Master Warning Light: Comes on |
|
| P1C109E | Current after Boosting by PFC Boosting Circuit Overvoltage Detection Circuit Stuck On | Comes on | Master Warning Light: Comes on |
|
| P1C1516 | Hybrid/EV Battery Charger Input Voltage Sensor for Monitoring Circuit Voltage Below Threshold | Comes on | Master Warning Light: Comes on |
|
| P1C1517 | Hybrid/EV Battery Charger Input Voltage Sensor for Monitoring Circuit Voltage Above Threshold | Comes on | Master Warning Light: Comes on |
|
| P1C1B00 | PFC Boosting Circuit Malfunction | Comes on | Master Warning Light: Comes on |
|
| P1C1C00 | DC/DC Converter Malfunction (for Charging) | Comes on | Master Warning Light: Comes on |
|
| P1C1D00 | Charging Power Low | Comes on | Master Warning Light: Comes on |
|
| P1C1E00 | Charging Power High | Comes on | Master Warning Light: Comes on |
|
| P1C1F49 | Hybrid/EV Battery Charger Control Module A/D Processing Internal Electronic Failure | Comes on | Master Warning Light: Comes on |
|
| P1C2562 | PFC Inverter Temperature Sensor/DC/DC Converter for Charging Temperature Sensor Signal Compare Failure | Does not come on | Master Warning Light: Comes on |
|
| P1C2617 | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Voltage Above Threshold | Comes on | Master Warning Light: Comes on |
|
| P1C2717 | Voltage Sensor after Boosting by PFC Boosting Circuit Circuit Voltage Above Threshold | Comes on | Master Warning Light: Comes on |
|
| P1C2819 | Current after Boosting by PFC Boosting Circuit Circuit Current Above Threshold | Comes on | Master Warning Light: Comes on |
|
| P1CA400 | Charger Pre-charging Malfunction | Comes on | Master Warning Light: Comes on |
|
| P1CCD96 | Sub DC/DC Converter (for Charging) Component Internal Failure | Does not come on | Master Warning Light: Comes on |
|
| P1CCD9E | Sub DC/DC Converter (for Charging) Stuck On | Does not come on | Master Warning Light: Comes on |
|
| P1CCD9F | Sub DC/DC Converter (for Charging) Stuck Off | Does not come on | Master Warning Light: Comes on |
|
| P1CCE12 | Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery | Does not come on | Master Warning Light: Comes on |
|
| P1CCE14 | Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open | Does not come on | Master Warning Light: Comes on |
|
| P1CCE1C | Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Voltage Out of Range | Does not come on | Master Warning Light: Comes on |
|
| P1CE931 | Charger Cooling Fan Revolution Signal No Signal | Does not come on | Master Warning Light: Comes on |
|
| P1CE996 | Charger Cooling Fan Revolution Signal Component Internal Failure | Does not come on | Master Warning Light: Comes on |
|
| P1CED1C | Plug-in Control ECU Power Supply (+12.5V) Circuit Voltage Out of Range | Does not come on | Master Warning Light: Comes on |
|
| P1CF01C | Plug-in Control ECU Power Supply (-7.5V) Circuit Voltage Out of Range | Does not come on | Master Warning Light: Comes on |
|
| P1CF31C | Plug-in Control ECU Power Supply (+1.15V) Circuit Voltage Out of Range | Does not come on | Master Warning Light: Comes on |
|
| P1CF662 | Charging Voltage Sensor for Monitoring/Control Signal Compare Failure | Comes on | Master Warning Light: Comes on |
|
| P319414 | Internal Control Module Circuit Short to Ground or Open | Does not come on | Master Warning Light: Comes on |
|
| U010087 | Lost Communication with ECM/PCM "A" Missing Message | Comes on | Master Warning Light: Comes on |
|
| U015587 | Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message | Does not come on | Master Warning Light: Does not come on |
|
| U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message | Comes on | Master Warning Light: Comes on |
|
| U115087 | Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message | Comes on | Master Warning Light: Comes on |