| DTC No. | Detection Item | DTC Detection Condition | MIL | Warning Indicate | Link |
|---|---|---|---|---|---|
| P056014 | System Voltage (BATT) Circuit Short to Ground or Open | Malfunction in the battery ECU assembly back-up power source circuit (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P060629 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Signal Invalid | ECU internal malfunction (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | ECU internal malfunction (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure | ECU internal malfunction (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P060A87 | Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message | ECU internal malfunction (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P060B16 | Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold | ECU internal malfunction (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | ECU internal malfunction (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P062F44 | Hybrid/EV Battery Energy Control Module EEPROM Data Memory Failure | ECU internal malfunction (1 trip detection logic) |
Comes on | Master Warning Light: Does not come on |
|
| P062F46 | Hybrid/EV Battery Energy Control Module EEPROM Calibration / Parameter Memory Failure | ECU internal malfunction (EEPROM error) (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0A1D94 | Hybrid/EV Powertrain Control Module Unexpected Operation | Hybrid vehicle control ECU internal malfunction: An abnormal signal from the hybrid vehicle control ECU is detected by the battery ECU assembly. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0A8111 | Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground | Both of the following conditions are met:
(1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0A8115 | Hybrid/EV Battery Cooling Fan 1 Circuit Short to Auxiliary Battery or Open | Both of the following conditions are met:
(1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0A8196 | Hybrid/EV Battery Cooling Fan 1 Component Internal Failure | The battery cooling blower assembly (No. 0) is malfunctioning and the actual speed is not within the specified range of the target speed calculated by the ECU.* *: This DTC is not stored when "Hybrid Battery Cooling Fan 1 Frequency" is excessively low or high. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0A9563 | High Voltage Fuse Accumulated Load History | Accumulated thermal load of the high voltage fuse estimated by the battery ECU assembly exceeds the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0A9611 | Hybrid/EV Battery Cooling Fan 2 Circuit Short to Ground | Both of the following conditions are met:
(1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0A9615 | Hybrid/EV Battery Cooling Fan 2 Circuit Short to Auxiliary Battery or Open | Both of the following conditions are met:
|
Comes on | Master Warning Light: Comes on |
|
| P0A9696 | Hybrid/EV Battery Cooling Fan 2 Component Internal Failure | The battery cooling blower assembly (No. 1) is malfunctioning and the actual speed is not within the specified range of the target speed calculated by the ECU.* *: This DTC is not stored when "Hybrid Battery Cooling Fan 1 Frequency" is excessively low or high. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0A9B11 | Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Ground | The battery temperature sensor is malfunctioning, its output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0A9B15 | Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open | The battery temperature sensor is malfunctioning, its output voltage is higher than the specified value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0A9B1C | Hybrid/EV Battery Temperature Sensor "A" Voltage Out of Range | The performance of battery temperature sensor 0 is abnormal; the difference in output between it and other battery temperature sensors is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0A9B2A | Hybrid/EV Battery Temperature Sensor "A" Signal Stuck In Range | The performance of battery temperature sensor 0 is abnormal and its output is stuck. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0AAC11 | Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Ground | The inlet air temperature sensor 0 output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0AAC15 | Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open | The inlet air temperature sensor 0 output voltage is higher than the standard value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0AB111 | Hybrid/EV Battery Air Temperature Sensor "B" Circuit Short to Ground | The inlet air temperature sensor 1 output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0AB115 | Hybrid/EV Battery Air Temperature Sensor "B" Circuit Short to Auxiliary Battery or Open | The inlet air temperature sensor 1 output voltage is higher than the standard value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0ABF11 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground | The battery current sensor output voltage (IB0) is excessively low. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0ABF15 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open | The battery current sensor output voltage (IB0) is excessively high. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0ABF28 | Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure | The offset value of the battery current sensor is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0ABF2A | Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range | The hybrid battery voltage is changing but the hybrid battery current sensor output does not change. | Comes on | Master Warning Light: Comes on |
|
| P0AC511 | Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Ground | The battery temperature sensor is malfunctioning, its output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0AC515 | Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Auxiliary Battery or Open | The battery temperature sensor is malfunctioning, its output voltage is higher than the specified value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0AC51C | Hybrid/EV Battery Temperature Sensor "B" Voltage Out of Range | The performance of battery temperature sensor 1 is abnormal; the difference in output between it and other battery temperature sensors is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0AC52A | Hybrid/EV Battery Temperature Sensor "B" Signal Stuck In Range | The performance of battery temperature sensor 1 is abnormal and its output is stuck. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0ACA11 | Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Ground | The battery temperature sensor is malfunctioning, its output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0ACA15 | Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open | The battery temperature sensor is malfunctioning, its output voltage is higher than the specified value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0ACA1C | Hybrid/EV Battery Temperature Sensor "C" Voltage Out of Range | The performance of battery temperature sensor 2 is abnormal; the difference in output between it and other battery temperature sensors is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0ACA2A | Hybrid/EV Battery Temperature Sensor "C" Signal Stuck In Range | The performance of battery temperature sensor 2 is abnormal and its output is stuck. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0AE811 | Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Ground | The battery temperature sensor is malfunctioning, its output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0AE815 | Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Auxiliary Battery or Open | The battery temperature sensor is malfunctioning, its output voltage is higher than the specified value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0AE81C | Hybrid/EV Battery Temperature Sensor "D" Voltage Out of Range | The performance of battery temperature sensor 3 is abnormal; the difference in output between it and other battery temperature sensors is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0AE82A | Hybrid/EV Battery Temperature Sensor "D" Signal Stuck In Range | The performance of battery temperature sensor 3 is abnormal and its output is stuck. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0B0E11 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground | The battery current sensor output voltage (IB1) is excessively low. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0B0E15 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open | The battery current sensor output voltage (IB1) is excessively high. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0B1362 | Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure | A battery current sensor is malfunctioning. *1 (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0BC211 | Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Ground | The battery temperature sensor is malfunctioning, its output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0BC215 | Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Auxiliary Battery or Open | The battery temperature sensor is malfunctioning, its output voltage is higher than the specified value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0BC21C | Hybrid/EV Battery Temperature Sensor "E" Voltage Out of Range | The performance of battery temperature sensor 4 is abnormal; the difference in output between it and other battery temperature sensors is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0BC22A | Hybrid/EV Battery Temperature Sensor "E" Signal Stuck In Range | The performance of battery temperature sensor 4 is abnormal and its output is stuck. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0C3000 | Hybrid/EV Battery State of Charge High | Even though charging of the HV battery is prohibited due to the SOC reaching the upper limit, charging continues to be performed due to a hybrid control system malfunction. (1 trip detection logic) |
Does not come on | Master Warning Light: Comes on |
|
| P0C3311 | Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Ground | The battery temperature sensor is malfunctioning, its output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0C3315 | Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Auxiliary Battery or Open | The battery temperature sensor is malfunctioning, its output voltage is higher than the specified value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0C331C | Hybrid/EV Battery Temperature Sensor "F" Voltage Out of Range | The performance of battery temperature sensor 5 is abnormal; the difference in output between it and other battery temperature sensors is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0C332A | Hybrid/EV Battery Temperature Sensor "F" Signal Stuck In Range | The performance of battery temperature sensor 5 is abnormal and its output is stuck. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0C7C11 | Hybrid/EV Battery Temperature Sensor "G" Circuit Short to Ground | The battery temperature sensor is malfunctioning, its output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0C7C15 | Hybrid/EV Battery Temperature Sensor "G" Circuit Short to Auxiliary Battery or Open | The battery temperature sensor is malfunctioning, its output voltage is higher than the specified value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0C7C1C | Hybrid/EV Battery Temperature Sensor "G" Voltage Out of Range | The performance of battery temperature sensor 6 is abnormal; the difference in output between it and other battery temperature sensors is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0C7C2A | Hybrid/EV Battery Temperature Sensor "G" Signal Stuck In Range | The performance of battery temperature sensor 6 is abnormal and its output is stuck. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0C8111 | Hybrid/EV Battery Temperature Sensor "H" Circuit Short to Ground | The battery temperature sensor is malfunctioning, its output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0C8115 | Hybrid/EV Battery Temperature Sensor "H" Circuit Short to Auxiliary Battery or Open | The battery temperature sensor is malfunctioning, its output voltage is higher than the specified value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0C811C | Hybrid/EV Battery Temperature Sensor "H" Voltage Out of Range | The performance of battery temperature sensor 7 is abnormal; the difference in output between it and other battery temperature sensors is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0C812A | Hybrid/EV Battery Temperature Sensor "H" Signal Stuck In Range | The performance of battery temperature sensor 7 is abnormal and its output is stuck. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0C8811 | Hybrid/EV Battery Temperature Sensor "I" Circuit Short to Ground | The battery temperature sensor is malfunctioning, its output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0C8815 | Hybrid/EV Battery Temperature Sensor "I" Circuit Short to Auxiliary Battery or Open | The battery temperature sensor is malfunctioning, its output voltage is higher than the specified value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0C881C | Hybrid/EV Battery Temperature Sensor "I" Voltage Out of Range | The performance of battery temperature sensor 8 is abnormal; the difference in output between it and other battery temperature sensors is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0C882A | Hybrid/EV Battery Temperature Sensor "I" Signal Stuck In Range | The performance of battery temperature sensor 8 is abnormal and its output is stuck. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0C8D11 | Hybrid/EV Battery Temperature Sensor "J" Circuit Short to Ground | The battery temperature sensor is malfunctioning, its output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0C8D15 | Hybrid/EV Battery Temperature Sensor "J" Circuit Short to Auxiliary Battery or Open | The battery temperature sensor is malfunctioning, its output voltage is higher than the specified value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0C8D1C | Hybrid/EV Battery Temperature Sensor "J" Voltage Out of Range | The performance of battery temperature sensor 9 is abnormal; the difference in output between it and other battery temperature sensors is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0C8D2A | Hybrid/EV Battery Temperature Sensor "J" Signal Stuck In Range | The performance of battery temperature sensor 9 is abnormal and its output is stuck. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0C9211 | Hybrid/EV Battery Temperature Sensor "K" Circuit Short to Ground | The battery temperature sensor is malfunctioning, its output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0C9215 | Hybrid/EV Battery Temperature Sensor "K" Circuit Short to Auxiliary Battery or Open | The battery temperature sensor is malfunctioning, its output voltage is higher than the specified value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0C921C | Hybrid/EV Battery Temperature Sensor "K" Voltage Out of Range | The performance of battery temperature sensor 10 is abnormal; the difference in output between it and other battery temperature sensors is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0C922A | Hybrid/EV Battery Temperature Sensor "K" Signal Stuck In Range | The performance of battery temperature sensor 10 is abnormal and its output is stuck. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0C9711 | Hybrid/EV Battery Temperature Sensor "L" Circuit Short to Ground | The battery temperature sensor is malfunctioning, its output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0C9715 | Hybrid/EV Battery Temperature Sensor "L" Circuit Short to Auxiliary Battery or Open | The battery temperature sensor is malfunctioning, its output voltage is higher than the specified value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0C971C | Hybrid/EV Battery Temperature Sensor "L" Voltage Out of Range | The performance of battery temperature sensor 11 is abnormal; the difference in output between it and other battery temperature sensors is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0C972A | Hybrid/EV Battery Temperature Sensor "L" Signal Stuck In Range | The performance of battery temperature sensor 11 is abnormal and its output is stuck. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0CA811 | Hybrid/EV Battery Temperature Sensor "M" Circuit Short to Ground | The battery temperature sensor is malfunctioning, its output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0CA815 | Hybrid/EV Battery Temperature Sensor "M" Circuit Short to Auxiliary Battery or Open | The battery temperature sensor is malfunctioning, its output voltage is higher than the specified value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0CA81C | Hybrid/EV Battery Temperature Sensor "M" Voltage Out of Range | The performance of battery temperature sensor 12 is abnormal; the difference in output between it and other battery temperature sensors is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0CA82A | Hybrid/EV Battery Temperature Sensor "M" Signal Stuck In Range | The performance of battery temperature sensor 12 is abnormal and its output is stuck. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0CAD11 | Hybrid/EV Battery Temperature Sensor "N" Circuit Short to Ground | The battery temperature sensor is malfunctioning, its output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0CAD15 | Hybrid/EV Battery Temperature Sensor "N" Circuit Short to Auxiliary Battery or Open | The battery temperature sensor is malfunctioning, its output voltage is higher than the specified value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0CAD1C | Hybrid/EV Battery Temperature Sensor "N" Voltage Out of Range | The performance of battery temperature sensor 13 is abnormal; the difference in output between it and other battery temperature sensors is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0CAD2A | Hybrid/EV Battery Temperature Sensor "N" Signal Stuck In Range | The performance of battery temperature sensor 13 is abnormal and its output is stuck. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0CB211 | Hybrid/EV Battery Temperature Sensor "O" Circuit Short to Ground | The battery temperature sensor is malfunctioning, its output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0CB215 | Hybrid/EV Battery Temperature Sensor "O" Circuit Short to Auxiliary Battery or Open | The battery temperature sensor is malfunctioning, its output voltage is higher than the specified value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: | |
| P0CB21C | Hybrid/EV Battery Temperature Sensor "O" Voltage Out of Range | The performance of battery temperature sensor 14 is abnormal; the difference in output between it and other battery temperature sensors is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0CB22A | Hybrid/EV Battery Temperature Sensor "O" Signal Stuck In Range | The performance of battery temperature sensor 14 is abnormal and its output is stuck. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0D0A11 | Hybrid/EV Battery Charging System Positive Contactor Control Circuit Short to Ground | Short to ground in the CHRB circuit: Primary circuit of CHR (+) is malfunctioning. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0D0A15 | Hybrid/EV Battery Charging System Positive Contactor Control Circuit Short to Auxiliary Battery or Open | Open or short to +B in the CHRB circuit: Primary circuit of CHR (+) is malfunctioning. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0D1111 | Hybrid/EV Battery Charging System Negative Contactor Control Circuit Short to Ground | Short to ground in the CHRG circuit: Primary circuit of CHR (-) is malfunctioning. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0D1115 | Hybrid/EV Battery Charging System Negative Contactor Control Circuit Short to Auxiliary Battery or Open | Open or short to +B in CHRG circuit: Primary circuit of CHR (-) is malfunctioning. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0E2D00 | Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance | The battery ECU assembly detects a malfunction of its internal HV battery cell voltage detection circuits. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0E6D11 | Hybrid/EV Battery Charging System Precharge Contactor Control Circuit Short to Ground | Short to ground in the CHRP circuit: Primary circuit of CHRP is malfunctioning. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P0E6D15 | Hybrid/EV Battery Charging System Precharge Contactor Control Circuit Short to Auxiliary Battery or Open | Open or short to +B in CHRP circuit: Primary circuit of CHRP is malfunctioning. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A001C | Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range | An open is detected in the HV battery cell voltage detection circuits of the No. 2 HV supply stack sub-assembly. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A051C | Hybrid Battery Stack 3 Cell Voltage Detection Voltage Out of Range | An open is detected in the HV battery cell voltage detection circuits of the No. 3 HV supply stack sub-assembly. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A0A1C | Hybrid Battery Stack 4 Cell Voltage Detection Voltage Out of Range | An open is detected in the HV battery cell voltage detection circuits of the No. 4 HV supply stack sub-assembly. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A101C | Hybrid Battery Stack 5 Cell Voltage Detection Voltage Out of Range | An open is detected in the HV battery cell voltage detection circuits of the No. 5 HV supply stack sub-assembly. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A6017 | Hybrid/EV Battery Stack 2 Cell Circuit Voltage Above Threshold | Charging continues to be performed after the voltage of any cell of the No. 2 HV supply stack sub-assembly has exceeded the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A6116 | Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold | The voltage of any cell of the No. 2 HV supply stack sub-assembly has decreased excessively. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A6317 | Hybrid/EV Battery Stack 3 Cell Circuit Voltage Above Threshold | Charging continues to be performed after the voltage of any cell of the No. 3 HV supply stack sub-assembly has exceeded the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A6416 | Hybrid/EV Battery Stack 3 Cell Circuit Voltage Below Threshold | The voltage of any cell of the No. 3 HV supply stack sub-assembly has decreased excessively. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A6617 | Hybrid/EV Battery Stack 4 Cell Circuit Voltage Above Threshold | Charging continues to be performed after the voltage of any cell of the No. 4 HV supply stack sub-assembly has exceeded the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A6716 | Hybrid/EV Battery Stack 4 Cell Circuit Voltage Below Threshold | The voltage of any cell of the No. 4 HV supply stack sub-assembly has decreased excessively. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A6917 | Hybrid/EV Battery Stack 5 Cell Circuit Voltage Above Threshold | Charging continues to be performed after the voltage of any cell of the No. 5 HV supply stack sub-assembly has exceeded the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A6A16 | Hybrid/EV Battery Stack 5 Cell Circuit Voltage Below Threshold | The voltage of any cell of the No. 5 HV supply stack sub-assembly has decreased excessively. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A8000 | Hybrid/EV Battery Stack 1 Delta SOC High | The difference in capacity of each cell of the No. 1 HV supply stack sub-assembly exceeds the specified value. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A8100 | Hybrid/EV Battery Stack 1 Delta SOC High (Extreme) | The difference in capacity of each cell of the No. 1 HV supply stack sub-assembly exceeds the specified value excessively. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A8500 | Hybrid/EV Battery Stack 2 Delta SOC High | The difference in capacity of each cell of the No. 2 HV supply stack sub-assembly exceeds the specified value. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A8600 | Hybrid/EV Battery Stack 2 Delta SOC High (Extreme) | The difference in capacity of each cell of the No. 2 HV supply stack sub-assembly exceeds the specified value excessively. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A8A00 | Hybrid/EV Battery Stack 3 Delta SOC High | The difference in capacity of each cell of the No. 3 HV supply stack sub-assembly exceeds the specified value. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A8B00 | Hybrid/EV Battery Stack 3 Delta SOC High (Extreme) | The difference in capacity of each cell of the No. 3 HV supply stack sub-assembly exceeds the specified value excessively. | Comes on | Master Warning Light: Comes on |
|
| P1A9000 | Hybrid/EV Battery Stack 4 Delta SOC High | The difference in capacity of each cell of the No. 4 HV supply stack sub-assembly exceeds the specified value. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A9100 | Hybrid/EV Battery Stack 4 Delta SOC High (Extreme) | The difference in capacity of each cell of the No. 4 HV supply stack sub-assembly exceeds the specified value excessively. | Comes on | Master Warning Light: Comes on |
|
| P1A9500 | Hybrid/EV Battery Stack 5 Delta SOC High | The difference in capacity of each cell of the No. 5 HV supply stack sub-assembly exceeds the specified value. (2 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1A9600 | Hybrid/EV Battery Stack 5 Delta SOC High (Extreme) | The difference in capacity of each cell of the No. 5 HV supply stack sub-assembly exceeds the specified value excessively. | Comes on | Master Warning Light: Comes on |
|
| P1AC413 | Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open | A shut-off by a CID occurs. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1AC49E | Hybrid/EV Battery Stack 1 Current Interrupt Device Stuck On | Conductivity returns after high voltage circuit disconnected by CID operation. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1AC513 | Hybrid/EV Battery Stack 2 Current Interrupt Device Circuit Open | A shut-off by a CID occurs. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1AC59E | Hybrid/EV Battery Stack 2 Current Interrupt Device Stuck On | Conductivity returns after high voltage circuit disconnected by CID operation. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1AC613 | Hybrid/EV Battery Stack 3 Current Interrupt Device Circuit Open | A shut-off by a CID occurs. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1AC69E | Hybrid/EV Battery Stack 3 Current Interrupt Device Stuck On | Conductivity returns after high voltage circuit disconnected by CID operation. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1AC713 | Hybrid/EV Battery Stack 4 Current Interrupt Device Circuit Open | A shut-off by a CID occurs. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1AC79E | Hybrid/EV Battery Stack 4 Current Interrupt Device Stuck On | Conductivity returns after high voltage circuit disconnected by CID operation. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1AC813 | Hybrid/EV Battery Stack 5 Current Interrupt Device Circuit Open | A shut-off by a CID occurs. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1AC89E | Hybrid/EV Battery Stack 5 Current Interrupt Device Stuck On | Conductivity returns after high voltage circuit disconnected by CID operation. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1AFC00 | System Voltage (AM) Circuit Voltage Below Threshold | The battery ECU assembly shutdown memory procedure did not complete normally in consecutive 40 trips. (1 trip detection logic) |
Does not come on | Master Warning Light: Comes on |
|
| P1AFD00 | Flying Capacitor Circuit Voltage Out of Range | ECU internal malfunction (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1AFD1C | Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range | Both of the following conditions are met: The battery ECU assembly detects a malfunction of its internal voltage detection circuits. The difference between the total voltage of all battery cells and the stack voltage is large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1AFF00 | Hybrid/EV Battery ECU Multiple Reset | ECU internal malfunction (1 trip detection logic) |
Does not come on | Master Warning Light: Comes on |
|
| P1B4011 | Hybrid/EV Battery Heater 1 Temperature Sensor Circuit Short to Ground | The HV battery heater temperature sensor 0 output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1B4015 | Hybrid/EV Battery Heater 1 Temperature Sensor Circuit Short to Auxiliary Battery or Open | The HV battery heater temperature sensor 0 output voltage is higher than the standard value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1B4511 | Hybrid/EV Battery Heater 2 Temperature Sensor Circuit Short to Ground | The HV battery heater temperature sensor 1 output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1B4515 | Hybrid/EV Battery Heater 2 Temperature Sensor Circuit Short to Auxiliary Battery or Open | The HV battery heater temperature sensor 1 output voltage is higher than the standard value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1B4A62 | Hybrid/EV Battery Heater Temperature Sensor Signal Compare Failure | The difference in the value of each HV battery heater temperature sensor (thermistor) is more than the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1B4B72 | Hybrid/EV Battery Heater Relay Actuator Stuck Open | The temperature of the HV battery does not increase even though the battery ECU assembly is outputing current to turn the HV battery heater relay on. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1B4B73 | Hybrid/EV Battery Heater Relay Actuator Stuck Closed | The temperature of the HV battery increases even though the battery ECU assembly is not outputing current to turn the HV battery heater relay on. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1B5011 | Junction Block Positive Contactor Temperature Sensor Circuit Short to Ground | The No. 2 HV battery junction block assembly temperature sensor output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1B5015 | Junction Block Positive Contactor Temperature Sensor Circuit Short to Auxiliary Battery or Open | The No. 2 HV battery junction block assembly temperature sensor output voltage is higher than the standard value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1B502A | Junction Block Positive Contactor Temperature Sensor Signal Stuck In Range | The performance of No. 2 HV battery junction block assembly temperature sensor is abnormal and its output is stuck. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1B5511 | Junction Block Negative Contactor Temperature Sensor Circuit Short to Ground | The No. 1 HV battery junction block assembly temperature sensor output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1B5515 | Junction Block Negative Contactor Temperature Sensor Circuit Short to Auxiliary Battery or Open | The No. 1 HV battery junction block assembly temperature sensor output voltage is higher than the standard value (short to +B or open) and the detected temperature is lower than the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1B552A | Junction Block Negative Contactor Temperature Sensor Signal Stuck In Range | The performance of No. 1 HV battery junction block assembly temperature sensor is abnormal and its output is stuck. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1B5A62 | Junction Block Positive / Negative Temperature Sensor Signal Compare Failure | The performance of any HV battery junction block assembly temperature sensor is abnormal and the difference in output between it and each other battery temperature sensor is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1C8549 | High Voltage Power Resource Internal Electronic Failure | An abnormal signal is detected by the battery ECU assembly (excessive discharging current). (1 trip detection logic) |
Does not come on | Master Warning Light: Comes on |
|
| P1C9F11 | Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Ground | "Hybrid Battery Current for Driving Control" (terminal IBA voltage) is excessively low (stuck at 5 V). (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1C9F15 | Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Auxiliary Battery or Open | "Hybrid Battery Current for Driving Control" (terminal IBA voltage) is excessively low (stuck at 0 V). (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1C9F1C | Hybrid/EV Battery Current Sensor for Driving Control Voltage Out of Range | The difference between IBA and IB0 exceeds the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1CBB12 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery | Power source voltage (VIB) of the battery current sensor is excessively high. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1CBB14 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open | Power source voltage (VIB) of the battery current sensor is excessively low. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1CC81E | Hybrid/EV Battery Stack 1 Voltage Difference Out of Range | The difference in voltage of each cell of the No. 1 HV supply stack sub-assembly exceeds the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1CC91E | Hybrid/EV Battery Stack 2 Voltage Difference Out of Range | The difference in voltage of each cell of the No. 2 HV supply stack sub-assembly exceeds the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1CCA1E | Hybrid/EV Battery Stack 3 Voltage Difference Out of Range | The difference in voltage of each cell of the No. 3 HV supply stack sub-assembly exceeds the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1CCB1E | Hybrid/EV Battery Stack 4 Voltage Difference Out of Range | The difference in voltage of each cell of the No. 4 HV supply stack sub-assembly exceeds the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P1CE51E | Hybrid/EV Battery Stack 5 Voltage Difference Out of Range | The difference in voltage of each cell of the No. 5 HV supply stack sub-assembly exceeds the specified value. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P300000 | Hybrid/EV Battery Discharge Control Malfunction | Discharging of the HV battery continues even after discharging is prohibited when the "SOC" has reached the lower limit. (1 trip detection logic) |
Does not come on | Master Warning Light: Does not come on |
|
| P300016 | Hybrid/EV Battery Control System Circuit Voltage Below Threshold | A malfunction signal is received from the battery ECU assembly. The voltage of any HV battery cell has decreased excessively. (1 trip detection logic) |
Does not come on | Master Warning Light: Comes on |
|
| P30004B | Hybrid/EV Battery Control System Over Temperature | The battery ECU assembly detects a HV battery cooling system error signal. (1 trip detection logic) |
Does not come on | Master Warning Light: Comes on |
|
| P301A1C | Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range | An open is detected in the HV battery cell voltage detection circuits of the No. 1 HV supply stack sub-assembly. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P306562 | Hybrid/EV Battery Temperature Sensor "Group 1" Signal Compare Failure | The performance of any battery temperature sensor (0 to 2) is abnormal and the difference in output between it and each other battery temperature sensor is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P306A62 | Hybrid/EV Battery Temperature Sensor "Group 2" Signal Compare Failure | The performance of any battery temperature sensor (3 to 5) is abnormal and the difference in output between it and each other battery temperature sensor is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P306B62 | Hybrid/EV Battery Temperature Sensor "Group 3" Signal Compare Failure | The performance of any battery temperature sensor (6 to 8) is abnormal and the difference in output between it and each other battery temperature sensor is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P306F62 | Hybrid/EV Battery Temperature Sensor "Group 4" Signal Compare Failure | The performance of any battery temperature sensor (9 to 11) is abnormal and the difference in output between it and each other battery temperature sensor is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P30FF62 | Hybrid/EV Battery Temperature Sensor "Group 5" Signal Compare Failure | The performance of any battery temperature sensor (12 to 14) is abnormal and the difference in output between it and each other battery temperature sensor is excessively large. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P310362 | Hybrid/EV Battery Air Temperature Sensor "A"/"B" Signal Compare Failure | The difference between the values of the two inlet air temperature sensor (thermistor) is above the specification. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P31AA17 | Hybrid/EV Battery Stack 1 Cell Circuit Voltage Above Threshold | Charging continues to be performed after the voltage of any cell of the No. 1 HV supply stack sub-assembly has exceeded the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P31AB16 | Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold | The voltage of any cell of the No. 1 HV supply stack sub-assembly has decreased excessively. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P31B300 | Hybrid/EV Battery Voltage High | Charging cannot be prohibited when the voltage of any HV battery cell has exceeded the specified threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P31B400 | Extreme Hybrid/EV Battery Charging Current | An abnormal signal is detected by the battery ECU assembly (excessive charging current). (1 trip detection logic) |
Does not come on | Master Warning Light: Comes on |
|
| P31B549 | Hybrid/EV Battery Internal Electronic Failure | An abnormal signal is detected by the battery ECU assembly (excessive discharging current). (1 trip detection logic) |
Does not come on | Master Warning Light: Comes on |
|
| P33DA1E | Hybrid/EV Battery Stack 1 Circuit Resistance Out of Range | The difference in internal resistance of each cell of the No. 1 HV supply stack sub-assembly exceeds the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P33DB1E | Hybrid/EV Battery Stack 2 Circuit Resistance Out of Range | The difference in internal resistance of each cell of the No. 2 HV supply stack sub-assembly exceeds the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P33DC1E | Hybrid/EV Battery Stack 3 Circuit Resistance Out of Range | The difference in internal resistance of each cell of the No. 3 HV supply stack sub-assembly exceeds the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P33DD1E | Hybrid/EV Battery Stack 4 Circuit Resistance Out of Range | The difference in internal resistance of each cell of the No. 4 HV supply stack sub-assembly exceeds the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P33DE1E | Hybrid/EV Battery Stack 5 Circuit Resistance Out of Range | The difference in internal resistance of each cell of the No. 5 HV supply stack sub-assembly exceeds the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P33E01B | Hybrid/EV Battery Stack 1 Circuit Resistance Above Threshold | The internal resistance of any cell of the No. 1 HV supply stack sub-assembly exceeds the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P33E11B | Hybrid/EV Battery Stack 2 Circuit Resistance Above Threshold | The internal resistance of any cell of the No. 2 HV supply stack sub-assembly exceeds the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P33E21B | Hybrid/EV Battery Stack 3 Circuit Resistance Above Threshold | The internal resistance of any cell of the No. 3 HV supply stack sub-assembly exceeds the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P33E31B | Hybrid/EV Battery Stack 4 Circuit Resistance Above Threshold | The internal resistance of any cell of the No. 4 HV supply stack sub-assembly exceeds the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P33E41B | Hybrid/EV Battery Stack 5 Circuit Resistance Above Threshold | The internal resistance of any cell of the No. 5 HV supply stack sub-assembly exceeds the threshold. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P33E600 | Hybrid/EV Battery Stack 1 Capacity Decline | Full charge capacity of the No. 1 HV supply stack sub-assembly is less than the specified value. (1 trip detection logic) |
Does not come on | Master Warning Light: Comes on |
|
| P33E700 | Hybrid/EV Battery Stack 2 Capacity Decline | Full charge capacity of the No. 2 HV supply stack sub-assembly is less than the specified value. (1 trip detection logic) |
Does not come on | Master Warning Light: Comes on |
|
| P33E800 | Hybrid/EV Battery Stack 3 Capacity Decline | Full charge capacity of the No. 3 HV supply stack sub-assembly is less than the specified value. (1 trip detection logic) |
Does not come on | Master Warning Light: Comes on |
|
| P33E900 | Hybrid/EV Battery Stack 4 Capacity Decline | Full charge capacity of the No. 4 HV supply stack sub-assembly is less than the specified value. (1 trip detection logic) |
Does not come on | Master Warning Light: Comes on |
|
| P33EA00 | Hybrid/EV Battery Stack 5 Capacity Decline | Full charge capacity of the No. 5 HV supply stack sub-assembly is less than the specified value. (1 trip detection logic) |
Does not come on | Master Warning Light: Comes on |
|
| P33EC16 | (Extreme) Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold | The voltage of any cell of the No. 1 HV supply stack sub-assembly has decreased excessively. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P33ED16 | (Extreme) Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold | The voltage of any cell of the No. 2 HV supply stack sub-assembly has decreased excessively. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P33EE16 | (Extreme) Hybrid/EV Battery Stack 3 Cell Circuit Voltage Below Threshold | The voltage of any cell of the No. 3 HV supply stack sub-assembly has decreased excessively. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P33EF16 | (Extreme) Hybrid/EV Battery Stack 4 Cell Circuit Voltage Below Threshold | The voltage of any cell of the No. 4 HV supply stack sub-assembly has decreased excessively. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| P33F016 | (Extreme) Hybrid/EV Battery Stack 5 Cell Circuit Voltage Below Threshold | The voltage of any cell of the No. 5 HV supply stack sub-assembly has decreased excessively. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| U010087 | Lost Communication with ECM/PCM "A" Missing Message | A CAN communication error between the battery ECU assembly and ECM (CAN communication system malfunction) occurs (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message | A CAN communication error between the battery ECU assembly and hybrid vehicle control ECU (CAN communication system malfunction) occurs (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |
|
| U115087 | Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message | The battery ECU assembly does not receive any signals from the hybrid vehicle control ECU for 1 second or more. (1 trip detection logic) |
Comes on | Master Warning Light: Comes on |