MOTOR GENERATOR CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE CHART

Motor Generator Control System
DTC No. Detection Item MIL Warning Indicate Link
P033500 Crankshaft Position Sensor "A" Does not come on

Master Warning Light:

Comes on

Click here

P033531 Crankshaft Position Sensor "A" No Signal Does not come on

Master Warning Light:

Comes on

Click here

P034000 Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Does not come on

Master Warning Light:

Comes on

Click here

P034031 Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal Does not come on

Master Warning Light:

Comes on

Click here

P062F44 Internal Control Module EEPROM Data Memory Failure Comes on

Master Warning Light:

Does not come on

Click here

P062F46 Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure Comes on

Master Warning Light:

Comes on

Click here

P06B01C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range Comes on

Master Warning Light:

Comes on

Click here

P06D61C Generator Control Module Offset Power Circuit Voltage Out of Range Comes on

Master Warning Light:

Comes on

Click here

P0A0011 Motor Electronics Coolant Temperature Sensor Circuit Short to Ground Comes on

Master Warning Light:

Comes on

Click here

P0A0015 Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open Comes on

Master Warning Light:

Comes on

Click here

P0A001C Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range Comes on

Master Warning Light:

Comes on

Click here

P0A0812 DC/DC Converter Status Circuit Short to Battery Does not come on

Master Warning Light:

Comes on

Click here

P0A0814 DC/DC Converter Status Circuit Short to Ground or Open Does not come on

Master Warning Light:

Comes on

Click here

P0A1112 DC/DC Converter Enable Circuit Short to Battery Does not come on

Master Warning Light:

Comes on

Click here

P0A1114 DC/DC Converter Enable Circuit Short to Ground or Open Does not come on

Master Warning Light:

Comes on

Click here

P0A1A47 Generator Control Module Watchdog / Safety μC Failure Comes on

Master Warning Light:

Comes on

Click here

P0A1A49 Generator Control Module Internal Electronic Failure Comes on

Master Warning Light:

Comes on

Click here

P0A1B1F Generator Control Module Circuit Intermittent Comes on

Master Warning Light:

Comes on

Click here

P0A3F16 Drive Motor "A" Position Sensor Circuit Voltage Below Threshold Comes on

Master Warning Light:

Comes on

Click here

P0A3F1F Drive Motor "A" Position Sensor Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0A3F21 Drive Motor "A" Position Sensor Signal Amplitude < Minimum Comes on

Master Warning Light:

Comes on

Click here

P0A3F22 Drive Motor "A" Position Sensor Signal Amplitude > Maximum Comes on

Master Warning Light:

Comes on

Click here

P0A4B16 Generator Position Sensor Circuit Voltage Below Threshold Comes on

Master Warning Light:

Comes on

Click here

P0A4B1F Generator Position Sensor Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0A4B21 Generator Position Sensor Signal Amplitude < Minimum Comes on

Master Warning Light:

Comes on

Click here

P0A4B22 Generator Position Sensor Signal Amplitude > Maximum Comes on Master Warning Light:

Click here

P0A6012 Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery Does not come on

Master Warning Light:

Comes on

Click here

P0A6014 Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open Does not come on

Master Warning Light:

Comes on

Click here

P0A601C Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range Does not come on

Master Warning Light:

Comes on

Click here

P0A601F Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0A6312 Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery Does not come on

Master Warning Light:

Comes on

Click here

P0A6314 Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open Does not come on

Master Warning Light:

Comes on

Click here

P0A631C Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range Does not come on

Master Warning Light:

Comes on

Click here

P0A631F Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0A7873 Drive Motor "A" Inverter Actuator Stuck Closed Comes on

Master Warning Light:

Comes on

Click here

P0A789E Drive Motor "A" Inverter Stuck On Comes on

Master Warning Light:

Comes on

Click here

P0A7A73 Generator Inverter Actuator Stuck Closed Comes on

Master Warning Light:

Comes on

Click here

P0A7A9E Generator Inverter Stuck On Comes on

Master Warning Light:

Comes on

Click here

P0A9000 Drive Motor "A" Performance Comes on

Master Warning Light:

Comes on

Click here

P0A9200 Hybrid Generator Performance Comes on

Master Warning Light:

Comes on

Click here

P0A949E DC/DC Converter Stuck On Comes on

Master Warning Light:

Comes on

Click here

P0AED11 Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground Comes on

Master Warning Light:

Comes on

Click here

P0AED15 Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open Comes on

Master Warning Light:

Comes on

Click here

P0AED1C Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range Comes on

Master Warning Light:

Comes on

Click here

P0BE512 Drive Motor "A" Phase U Current Sensor Circuit Short to Battery Comes on

Master Warning Light:

Comes on

Click here

P0BE514 Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open Comes on

Master Warning Light:

Comes on

Click here

P0BE51F Drive Motor "A" Phase U Current Sensor Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0BE528 Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on

Master Warning Light:

Comes on

Click here

P0BE912 Drive Motor "A" Phase V Current Sensor Circuit Short to Battery Comes on

Master Warning Light:

Comes on

Click here

P0BE914 Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open Comes on

Master Warning Light:

Comes on

Click here

P0BE91F Drive Motor "A" Phase V Current Sensor Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0BE928 Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on

Master Warning Light:

Comes on

Click here

P0BED12 Drive Motor "A" Phase W Current Sensor Circuit Short to Battery Comes on

Master Warning Light:

Comes on

Click here

P0BED14 Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open Comes on

Master Warning Light:

Comes on

Click here

P0BED1F Drive Motor "A" Phase W Current Sensor Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0BED28 Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on

Master Warning Light:

Comes on

Click here

P0BFD62 Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure Comes on

Master Warning Light:

Comes on

Click here

P0BFF1D Drive Motor "A" Circuit Current Out of Range Comes on

Master Warning Light:

Comes on

Click here

P0C1900 Drive Motor "A" Execution Torque Performance Comes on

Master Warning Light:

Comes on

Click here

P0C3811 DC/DC Converter Temperature Sensor "A" Circuit Short to Ground Comes on

Master Warning Light:

Comes on

Click here

P0C3815 DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open Comes on

Master Warning Light:

Comes on

Click here

P0C381C DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range Comes on

Master Warning Light:

Comes on

Click here

P0C3D11 DC/DC Converter Temperature Sensor "B" Circuit Short to Ground Comes on

Master Warning Light:

Comes on

Click here

P0C3D15 DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open Comes on

Master Warning Light:

Comes on

Click here

P0C3D1C DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range Comes on

Master Warning Light:

Comes on

Click here

P0C5013 Drive Motor "A" Position Sensor Circuit "A" Circuit Open Comes on

Master Warning Light:

Comes on

Click here

P0C5016 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold Comes on

Master Warning Light:

Comes on

Click here

P0C5017 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold Comes on

Master Warning Light:

Comes on

Click here

P0C501F Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0C5A13 Drive Motor "A" Position Sensor Circuit "B" Circuit Open Comes on

Master Warning Light:

Comes on

Click here

P0C5A16 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold Comes on

Master Warning Light:

Comes on

Click here

P0C5A17 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold Comes on

Master Warning Light:

Comes on

Click here

P0C5A1F Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0C6413 Generator Position Sensor Circuit "A" Circuit Open Comes on

Master Warning Light:

Comes on

Click here

P0C6416 Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold Comes on

Master Warning Light:

Comes on

Click here

P0C6417 Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold Comes on

Master Warning Light:

Comes on

Click here

P0C641F Generator Position Sensor Circuit "A" Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0C6913 Generator Position Sensor Circuit "B" Circuit Open Comes on

Master Warning Light:

Comes on

Click here

P0C6916 Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold Comes on

Master Warning Light:

Comes on

Click here

P0C6917 Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold Comes on

Master Warning Light:

Comes on

Click here

P0C691F Generator Position Sensor Circuit "B" Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0C7917 Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold Comes on

Master Warning Light:

Comes on

Click here

P0CA300 DC/DC Converter Step Up Voltage Performance Comes on

Master Warning Light:

Comes on

Click here

P0D2D16 Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold Comes on

Master Warning Light:

Comes on

Click here

P0D2D17 Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold Comes on

Master Warning Light:

Comes on

Click here

P0D2D1F Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0D3319 DC/DC Converter Circuit Current Above Threshold Comes on

Master Warning Light:

Comes on

Click here

P0DFA62 Generator Phase U-V-W Current Sensor Signal Compare Failure Comes on

Master Warning Light:

Comes on

Click here

P0E0012 Generator Phase U Current Sensor Circuit Short to Battery Comes on

Master Warning Light:

Comes on

Click here

P0E0014 Generator Phase U Current Sensor Circuit Short to Ground or Open Comes on

Master Warning Light:

Comes on

Click here

P0E001F Generator Phase U Current Sensor Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0E0028 Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on

Master Warning Light:

Comes on

Click here

P0E0412 Generator Phase V Current Sensor Circuit Short to Battery Comes on

Master Warning Light:

Comes on

Click here

P0E0414 Generator Phase V Current Sensor Circuit Short to Ground or Open Comes on

Master Warning Light:

Comes on

Click here

P0E041F Generator Phase V Current Sensor Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0E0428 Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on

Master Warning Light:

Comes on

Click here

P0E0812 Generator Phase W Current Sensor Circuit Short to Battery Comes on

Master Warning Light:

Comes on

Click here

P0E0814 Generator Phase W Current Sensor Circuit Short to Ground or Open Comes on

Master Warning Light:

Comes on

Click here

P0E081F Generator Phase W Current Sensor Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0E0828 Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on

Master Warning Light:

Comes on

Click here

P0E3116 DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold Comes on

Master Warning Light:

Comes on

Click here

P0E3117 DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold Comes on

Master Warning Light:

Comes on

Click here

P0E311F DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0E5111 DC/DC Converter Current Sensor Circuit Short to Ground Comes on

Master Warning Light:

Comes on

Click here

P0E5115 DC/DC Converter Current Sensor Circuit Short to Battery or Open Comes on

Master Warning Light:

Comes on

Click here

P0E511F DC/DC Converter Current Sensor Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P0E5128 DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on

Master Warning Light:

Comes on

Click here

P0E5717 DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold Comes on

Master Warning Light:

Comes on

Click here

P0E5811 DC/DC Converter Temperature Sensor 2 Circuit Short to Ground Comes on

Master Warning Light:

Comes on

Click here

P0E5815 DC/DC Converter Temperature Sensor 2 Circuit Short to Battery or Open Comes on

Master Warning Light:

Comes on

Click here

P0E581C DC/DC Converter Temperature Sensor 2 Circuit Voltage Out of Range Comes on

Master Warning Light:

Comes on

Click here

P0E7100 Generator Execution Torque Performance Comes on

Master Warning Light:

Comes on

Click here

P155911 Reactor Temperature Sensor Circuit Short to Ground Comes on

Master Warning Light:

Comes on

Click here

P155915 Reactor Temperature Sensor Circuit Short to Battery or Open Comes on

Master Warning Light:

Comes on

Click here

P15591C Reactor Temperature Sensor Circuit Resistance Out of Range Comes on

Master Warning Light:

Comes on

Click here

P1C2A1C Generator A/D Converter Circuit Circuit Voltage Out of Range Comes on

Master Warning Light:

Comes on

Click here

P1C2A49 Generator A/D Converter Circuit Internal Electronic Failure Comes on

Master Warning Light:

Comes on

Click here

P1C2B1C Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range Comes on

Master Warning Light:

Comes on

Click here

P1C2B49 Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure Comes on

Master Warning Light:

Comes on

Click here

P1C2E46 Motor Generator ECU(EEPROM) Calibration / Parameter Memory Failure Does not come on

Master Warning Light:

Comes on

Click here

P1C5D19 Drive Motor "A" Inverter Circuit Current Above Threshold Comes on

Master Warning Light:

Comes on

Click here

P1C5F19 Generator Inverter Circuit Current Above Threshold Comes on

Master Warning Light:

Comes on

Click here

P1C601F Generator Control Module Position Sensor REF Power Source Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P1C621F Generator Control Module Offset Power Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P1C641F Generator Control Module Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P1C651F Generator Control Module Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P1C671F Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P1C691F Generator Phase U-V-W Current Sensor Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P1CA51D Hybrid Generator Circuit Current Out of Range Comes on

Master Warning Light:

Comes on

Click here

P1CAC49 Generator Position Sensor Internal Electronic Failure Comes on

Master Warning Light:

Comes on

Click here

P1CAD49 Drive Motor "A" Position Sensor Internal Electronic Failure Comes on

Master Warning Light:

Comes on

Click here

P1CAF38 Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect Comes on

Master Warning Light:

Comes on

Click here

P1CB038 Drive Motor "A" Position Sensor REF Signal Frequency Incorrect Comes on

Master Warning Light:

Comes on

Click here

P1CB59E DC/DC Converter Voltage Sensor "A"(VL) Stuck On Comes on

Master Warning Light:

Comes on

Click here

P1CB69E Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On Comes on

Master Warning Light:

Comes on

Click here

P1CB746 Generator Control Module(EEPRM Backup Power) Calibration / Parameter Memory Failure Does not come on

Master Warning Light:

Comes on

Click here

P1CB7A2 Motor Generator System Voltage Low Does not come on

Master Warning Light:

Comes on

Click here

P1CCC96 DC/DC Converter Enable Component Internal Failure Does not come on

Master Warning Light:

Comes on

Click here

P1CFF62 Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure Comes on

Master Warning Light:

Comes on

Click here

P31241F Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent Does not come on

Master Warning Light:

Does not come on

Click here

P312487 Lost Communication between Drive Motor "A" and HV ECU Missing Message Does not come on

Master Warning Light:

Comes on

Click here

P313383 Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect Comes on

Master Warning Light:

Comes on

Click here

P313386 Communication Error from Generator to Drive Motor "A" Signal Invalid Comes on

Master Warning Light:

Comes on

Click here

P313387 Communication Error from Generator to Drive Motor "A" Missing Message Comes on

Master Warning Light:

Comes on

Click here

P313483 Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect Comes on

Master Warning Light:

Comes on

Click here

P313486 Communication Error from Drive Motor "A" to Generator Signal Invalid Comes on

Master Warning Light:

Comes on

Click here

P313487 Communication Error from Drive Motor "A" to Generator Missing Message Comes on

Master Warning Light:

Comes on

Click here

P314F1F DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent Comes on

Master Warning Light:

Comes on

Click here

P31531D DC/DC Converter Current Sensor Circuit Current Out of Range Does not come on

Master Warning Light:

Comes on

Click here

U010087 Lost Communication With ECM/PCM "A" Missing Message Comes on

Master Warning Light:

Comes on

Click here

U029387 Lost Communication With Hybrid Powertrain Control Module Missing Message Comes on

Master Warning Light:

Comes on

Click here

U117087 Lost Communication With Brake System Control Module(ch2) Missing Message Comes on

Master Warning Light:

Comes on

Click here