DATA LIST
Note
Some Data List values may vary significantly if there are slight differences in the environment in which the vehicle is operating when measurements are obtained. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.
In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under identical conditions in order to reach an overall judgment by comparing all the items in the Data List.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Hybrid Control / Data List.
Check the results by referring to the following table.
Tech Tips
When reviewing Data List information, try to select only the specific Data List items related to the inspection being performed. If all items are selected when checking the Data List, the interval between updates for each item will be longer, resulting in delayed or incorrect data.
Using a custom list makes it possible to easily select smaller groups of related Data List items.
The following custom lists are available:
Primary
Hybrid Battery
Hybrid Battery Temperature
Inverter
Hybrid Coolant Temperature
Shift
Insulation Abnormal
SMR
Ready ON
DC/DC Converter
Auxiliary Battery
Resolver Learning
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Vehicle Speed | Vehicle speed | Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) | Vehicle stopped: 0 km/h (0 mph) While driving at a constant speed: No significant fluctuation |
- |
| Vehicle Speed when DC Quick Charging Connector Connect | Vehicle speed when connected to plug-in charger inlet | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (203.61 mph) | - | - |
| Target Engine Power | Target engine power | Min.: 0 W, Max.: 655350 W | While driving with the engine running: Varies depending on vehicle operating conditions |
Requested engine power by hybrid vehicle control ECU to ECM
|
| Execute Engine Power | Execute engine power | Min.: 0 W, Max.: 655350 W | While driving with the engine running: Varies depending on vehicle operating conditions |
- |
| Target Engine Revolution | Target engine revolution | Min.: 0 rpm, Max.: 65535 rpm | While driving with the engine running: Varies depending on vehicle operating conditions |
Target engine speed requested by hybrid vehicle control ECU to ECM
|
| Engine Speed | Engine speed | Min.: 0.00 rpm, Max.: 16383.75 rpm | Engine stopped: 0 rpm While engine running at a constant speed: No significant fluctuation |
- |
| Calculate Load | Calculate load | Min.: 0.0%, Max.: 100.0% | - | Value increases in proportion to increase in load
|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Cold start→Fully warmed up: Gradually rises After warming up: 75 to 100°C (167 to 212°F) |
- |
| Starter Switch Signal | Starter ON / OFF signal | ON or OFF | Starter ON: ON |
- |
| Engine Idling Request | Engine idling request | ON or OFF | Requesting idle: ON |
|
| Engine Start Request (A/C) | Engine idling request from air conditioning amplifier assembly | ON or OFF | While an engine start is requested from the air conditioning amplifier assembly: ON |
Air conditioning amplifier assembly |
| Engine Start Request (Engine Warm-up) | Engine idling request to warm up engine | ON or OFF | While an engine warm-up is requested: ON After the engine is warmed up: OFF |
|
| Engine Start Request (Hybrid Battery Charging) | Engine idling request to charge HV battery | ON or OFF | Requesting HV battery charging: ON |
|
| Engine Mode | Engine status | Stop / Stop Process / Startup Process / Running | Engine stopped: Stop Engine stopping: Stop Process While the Engine starting: Startup Process Engine running: Running |
|
| Engine Run Time | Elapsed time after starting engine | Min.: 0 sec, Max.: 65535 sec | Elapsed time after starting engine | Elapsed time from initial engine start until the power switch is turned off. |
| Engine Stop Request | Engine stop request | ON or OFF | Requesting engine stop: ON |
|
| Engine Stop F/C Status | Engine fuel cut status | ON or OFF | While engine fuel cut: ON |
|
| Lack of Fuel | Lack of fuel | ON or OFF | Fuel level low: ON |
- |
| Accelerator Position | Accelerator pedal depressed angle | Min.: 0.0%, Max.: 127.5% | Accelerator pedal fully depressed: 100% Accelerator pedal released: 0% |
Accelerator pedal sensor assembly |
| Accelerator Pedal Status | Accelerator Pedal Status | ON or OFF | Accelerator pedal depressed: ON Accelerator pedal released: OFF |
Accelerator pedal sensor assembly |
| Accelerator Position Sensor No.1 Voltage % | Accelerator pedal position sensor No. 1 | Min.: 0.00%, Max.: 100.00% | Accelerator pedal depressed: Changes with accelerator pedal position |
Sensor voltage is multiplied by 20 and displayed as a percentage
|
| Accelerator Position Sensor No.2 Voltage % | Accelerator pedal position sensor No. 2 | Min.: 0.00%, Max.: 100.00% | Accelerator pedal depressed: Changes with accelerator pedal position |
Sensor voltage is multiplied by 20 and displayed as a percentage
|
| Throttle Position Sensor No.1 Voltage % | Throttle position sensor | Min.: 0.0%, Max.: 100.0% | - | Throttle valve status |
| Master Cylinder Control Torque | Braking torque equivalent to master cylinder brake fluid pressure (Total braking torque) |
Min.: -4096 Nm, Max.: 4095.87 Nm | Brake pedal depressed: Changes with the brake pedal pressure |
Master cylinder brake fluid pressure control torque = hydraulic brake control torque + regenerative brake torque
|
| Brake Cancel Switch | Brake Cancel Switch | ON or OFF | Brake pedal depressed: OFF Brake pedal released: ON |
- |
| Shift Position | Current shift state | P / R / N / D / B | Matches currently selected shift state: P, R, N, D or B |
Shift state
|
| Shift Position (Meter) | Shift position of meter display | Not Displayed / P / R / N / D / B | Matches currently selected shift state: P, R, N, D or B |
Shift state |
| Shift Switch Status (N,P Position) | Shift position status (N or P position) | ON or OFF | Shift state P or N: ON |
Shift state |
| P Position Switch Terminal Voltage | Indicates voltage at the P position switch terminal | Min.: 0.00 V, Max.: 4.99 V | P position switch ON: 0.00 to 1.50 V |
- |
| Shift Sensor Voltage (VSI1) | Shift sensor (VSI1) voltage | Min: 0.00 V, Max: 4.99 V | Shift lever in D: 1.63 to 2.40 V Shift lever in N: 0.68 to 1.62 V Shift lever in R: 0.40 to 0.67 V Shift lever in B: 2.75 to 3.52 V Shift lever in Home: 3.53 to 4.47 V |
- |
| Shift Sensor Voltage (VSI2) | Shift sensor (VSI2) voltage | Min: 0.00 V, Max: 4.99 V | Shift lever in D: 2.70 to 3.52 V Shift lever in N: 1.63 to 2.70 V Shift lever in R: 0.98 to 1.62 V Shift lever in B: 1.63 to 2.45 V Shift lever in Home: 2.45 to 3.52 V |
- |
| Shift Sensor Voltage (VSI3) | Shift sensor (VSI3) voltage | Min: 0.00 V, Max: 4.99 V | Shift lever in D: 3.53 to 4.17 V Shift lever in N: 2.45 to 3.52 V Shift lever in R: 1.63 to 2.45 V Shift lever in B: 0.98 to 1.63 V Shift lever in Home: 1.63 to 2.70 V |
- |
| Shift Sensor Voltage (VSI4) | Shift sensor (VSI4) voltage | Min: 0.00 V, Max: 4.99 V | Shift lever in D: 4.47 to 4.75 V Shift lever in N: 3.53 to 4.47 V Shift lever in R: 2.75 to 3.52 V Shift lever in B: 0.40 to 0.67 V Shift lever in Home: 0.68 to 1.62 V |
- |
| Transaxle Oil Temperature | Hybrid vehicle transaxle oil temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F) While driving: Varies depending on vehicle operating conditions |
- |
| Transaxle Oil Temperature Sensor Voltage | Hybrid vehicle transaxle oil temperature sensor voltage | Min: 0.00 V, Max: 4.99 V | - | - |
| FR Wheel Speed | Front wheel speed RH | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph) | Vehicle stopped: 0 km/h (0 mph) Vehicle being driven at a constant speed: No large fluctuations in displayed speed |
- |
| FL Wheel Speed | Front wheel speed LH | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph) | Vehicle stopped: 0 km/h (0 mph) Vehicle being driven at a constant speed: No large fluctuations in displayed speed |
- |
| RR Wheel Speed | Rear wheel speed RH | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph) | Vehicle stopped: 0 km/h (0 mph) Vehicle being driven at a constant speed: No large fluctuations in displayed speed |
- |
| RL Wheel Speed | Rear wheel speed LH | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph) | Vehicle stopped: 0 km/h (0 mph) Vehicle being driven at a constant speed: No large fluctuations in displayed speed |
- |
| Atmospheric Pressure | Atmospheric pressure | Min.: 0 kPa (0 psi), Max.: 255 kPa (37 psi) | Constant: Atmosphere pressure |
- |
| Intake Manifold Absolute Pressure | Intake manifold pressure of engine | Min.: 0.00 kPa (0 psi), Max.: 2047.96 kPa (297 psi) | Power switch on (IG) or engine stopped: Atmosphere pressure |
Values less than atmospheric pressure are indicated while the engine is running |
| Ambient Temperature | Ambient air temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Power switch on (IG): Same as ambient air temperature |
Ambient temperature sensor |
| Intake Air Temperature | Engine intake air temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Constant: Almost same as ambient air temperature |
- |
| BATT Voltage | Auxiliary battery voltage (Battery ECU assembly power source voltage) |
Min.: 0.00 V, Max.: 16.00 V | 11.00 to 15.00 V | BATT terminal |
| Smoothed Value of BATT Voltage | Smoothed value of auxiliary battery voltage | Min.: 0.00 V, Max.: 16.00 V | 11.000 to 15.000 V | Hybrid vehicle control ECU |
| Warmup Cycle Cleared DTC | The number of times the engine is warmed up after clearing DTCs | Min.: 0, Max.: 255 | MIL OFF, engine coolant temperature increases from below 22°C (71.6°F) before starting the engine to above 70°C (158°F) after starting the engine: Increases once |
- |
| Distance from DTC Cleared | Drive distance after clearing DTCs | Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) | - | - |
| Time after DTC Cleared | Elapsed time after clearing DTCs | Min.: 0 min, Max.: 65535 min | - | Time elapsed after DTCs are cleared (Not counted when the power switch is off). |
| MIL | MIL status | ON or OFF | - | - |
| Running Time from MIL ON | Running time from MIL on | Min.: 0 min, Max.: 65535 min | - | - |
| Total Distance Traveled | Drive total distance | Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile) | - | - |
| MIL ON Run Distance | Drive distance from MIL on | Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) | - | - |
| Number of Emission DTC | Emissions-related DTCs | Min.: 0, Max.: 127 | - | - |
| OBD Requirements | OBD Requirements | - | JOBD and EOBD | - |
| IG Switch (CAN) | Power switch status (CAN) | ON or OFF | Power switch being pushed and held: ON |
CAN communication system |
| IG Switch (LIN) | Power switch status (LIN) | ON or OFF | Power switch being pushed and held: ON |
LIN communication system |
| IGB Signal Status | IGB signal status | ON or OFF | Power switch on (IG) or on (READY): ON |
IGB terminal |
| IGB Keeping Status | IGB Keeping Status | ON or OFF | Power switch on (IG) or during charging: ON |
IGB terminal |
| IG2 Signal Status | IG2 signal status | ON or OFF | Power switch on (IG) or on (READY): ON |
IG2 terminal |
| +B3M Signal Status | +B3M Signal Status | ON or OFF | IGCT relay Operating: ON |
+B3M terminal |
| MRL2 Signal Status | MRL2 Signal Status | ON or OFF | IGCT relay Operating: ON |
MRL2 terminal |
| ACC Signal | ACC signal status | ON or OFF | - | - |
| Ready Signal | Ready signal status | ON or OFF | Power switch on (READY): ON |
- |
| HV Activate Condition | Hybrid vehicle control system power source mode status | Normal / Remote Air Control System / Remote | Hybrid Vehicle Control System started using power switch: Normal Hybrid vehicle control system started using remote air control system function: Remote Air Control System Hybrid vehicle control system started using remote starter: Remote |
- |
| MG Activate Condition | Motor generator control system status | ON or OFF | Power switch on (IG) or on (READY): ON |
- |
| DSS Control Status | Control status of DSS (Driving Support System) | Not Control / Available / Unavailable / Disable | - | - |
| Generate Torque (Request from DSS) | Generated drive torque requested from DSS (Driving Support System) | Min.: -4096.00 Nm, Max.: 4095.87 Nm | - | - |
| Primary Driving Force Adjustment Result | Result of adjustment between drive force of DSS (Driving Support System) and drive force requested by accelerator pedal operation | Accelerator / DSS | Drive force requested by Accelerator pedal operation selected: Accelerator Drive force requested by DSS selected: DSS |
- |
| SMRG Status | Operating state of SMRG (primary circuit monitor) |
ON or OFF | Power switch on (READY): ON |
|
| SMRG Control Status | Commanded state of SMRG | ON or OFF | Power switch on (READY): ON |
|
| SMRB Status | Operating state of SMRB (primary circuit monitor) |
ON or OFF | Power switch on (READY): ON |
|
| SMRB Control Status | Commanded state of SMRB | ON or OFF | Power switch on (READY): ON |
|
| SMRP Status | Operating state of SMRP (primary circuit monitor) |
ON or OFF | Immediately after the power switch on (ST-ON) state occurred: ON After the above timing: OFF |
Cannot be confirmed using the GTS. Use an oscilloscope.
|
| SMRP Control Status | Commanded state of SMRP | ON or OFF | Immediately after the power switch on (ST-ON) state occurred: ON After the above timing: OFF |
Cannot be confirmed using the GTS. Use an oscilloscope.
|
| WIN Control Limit Power | WIN control limit power | Min.: -327.68 kW, Max.: 327.67 kW | -27.4 kW | - |
| WOUT Control Limit Power | WOUT control limit power | Min.: -327.68 kW, Max.: 327.67 kW | HV mode: 24 kW or less EV mode: 68.4 kW or less |
- |
| Charging Permission Signal by Main CPU | Charging permission signal by main CPU | NG or OK | - | - |
| Charging Permission Signal by Sub CPU | Charging permission signal by sub CPU | NG or OK | - | - |
| Charging Permission Answerback Signal from Plug-in Control ECU | Charging permission answerback signal from plug-in control ECU | NG or OK | - | - |
| A/C Consumption Power | A/C consumption power | Min.: 0.00 kW, Max.: 12.75 kW | While the air conditioning system is operating: 0 to 5.00 kW |
Air conditioning system |
| A/C Useable Power | A/C useable power | Min.: 0.00 kW, Max.: 12.75 kW | - | - |
| Powertrain Drive Mode Switch | Drive mode select switch (pattern select switch assembly) condition | ON or OFF | Drive mode select switch (pattern select switch assembly) not operated: OFF Drive mode select switch (pattern select switch assembly) being pushed and held: ON |
Drive mode select switch circuit |
| HV/EV Mode Switch | HV/EV mode switch condition | ON or OFF | HV/EV switch not operated: OFF HV/EV switch being pushed and held: ON |
HV/EV switch circuit |
| EVMS Signal Status | EV CITY switch or EV AUTO switch signal condition | ON or OFF | EV CITY switch or EV AUTO switch not operated: OFF EV CITY switch or EV AUTO switch being pushed and held: ON |
EV CITY switch circuit EV AUTO switch circuit |
| EV Mode Status | EV mode status | Normal / EV Mode / Changing to HV Mode from EV Mode / Changing to EV Mode from HV Mode / EV CITY Mode / Changing to HV Mode from EV CITY Mode / Battery Charge Mode / Changing to HV Mode from Battery Charge Mode / Standby for Battery Charge Mode / EV AUTO Mode / Changing to HV Mode from EV AUTO Mode | - | - |
| Drive Mode | Hybrid vehicle control ECU recognized drive mode | None / EV Mode / HV Mode by Switch / HV Mode | - | - |
| Hybrid Control System Control Mode | Hybrid vehicle control ECU controlled vehicle mode | None / Driving Mode / External Power Supply Mode / Charging/Discharging Mode / Other | - | - |
| Inter Lock Switch | Interlock switch condition | ON or OFF | Power switch on (IG), service plug grip not installed: ON |
ILK terminal |
| Inter Lock Switch (MG) | Interlock switch condition | ON or OFF | Power switch on (IG), inverter cover not installed: ON |
Inverter with converter assembly |
| Stop Light Switch | Stop light switch assembly condition | ON or OFF | Brake pedal depressed: ON |
- |
| Back Up Light Relay | Back up light switch condition | ON or OFF | Shift lever in R: ON |
- |
| VSC/TRC OFF Switch | VSC condition | OFF / TRC OFF Mode / TRC/VSC OFF Mode | - | - |
| Airbag Status (Collision) | Airbag sensor assembly collision detection | ON or OFF | Collision detection by the airbag sensor assembly: ON |
- |
| Airbag Status (Collision) (CAN) | Airbag sensor assembly collision detection (CAN) |
Normal / Collision from Back / Airbag Circuit Abnormal / Safing / Collision from Front or Side | - | - |
| Airbag Status (Safing) | Safing state of the airbag sensor assembly | ON or OFF | When safing state of the airbag sensor assembly: ON |
- |
| Airbag Status (Normal) | Control state of airbag sensor assembly | ON or OFF | When the airbag sensor assembly is operating normally: ON |
- |
| Crank Position | Crankshaft position | Min.: -128 deg (CA), Max.: 127 deg (CA) | - | - |
| TC Terminal | TC terminal state | ON or OFF | TC terminal connected: ON |
- |
| Body Control with Torque Demand | Body Control with Torque Demand status | ON or OFF | Under the Body Control with Torque Demand: ON |
- |
| Remote Air Control System | Remote air conditioning system operability | Unable or Able | - | - |
| AC Charging | Plug-in charging operability | Unable or Able | - | - |
| Solar Charging | Solar charging operability*1 | Unable or Able | - | - |
| Elapsed time from HV ECU Boot Up | Time elapsed since hybrid vehicle control ECU started | Min.: 0 sec, Max.: 65535 sec | - | - |
| IG OFF Elapsed Time | Cumulative time since power switch turned off (from ECM) | Min.: 0 min, Max.: 655350 min | - | - |
| Generator Revolution | Generator (MG1) speed (detected by resolver sensor) | Min.: 32768 rpm, Max.: 32767 rpm | During charge or discharge: Varies depending on vehicle operating conditions |
Generator (MG1) speed is set to obtain requested target engine speed
|
| Target Generator Torque | Generator (MG1) torque request value | Min.: -4096.00 Nm, Max.: 4095.87 Nm | During charge or discharge: Varies depending on vehicle operating conditions |
|
| Generator Torque | Generator (MG1) torque execution value | Min.: -4096.00 Nm, Max.: 4095.87 Nm | One second after engine automatically starts with shift lever in P (Condition before engine start: Power switch on (READY), engine stopped, A/C fan speed high and headlights on): Within +/- 20% of target generator (MG1) torque |
|
| Motor Revolution | Motor (MG2) speed (detected by resolver sensor) | Min.: 32768 rpm, Max.: 32767 rpm | While driving: Varies depending on vehicle speed |
Motor (MG2) speed changes in proportion to vehicle speed. Motor (MG2) speed is not influenced by accelerator pedal opening angle, engine speed or generator (MG1) speed.
|
| Target Motor Torque | Motor (MG2) torque request value | Min.: -4096.00 Nm, Max.: 4095.87 Nm | While driving: Varies depending on vehicle operating conditions |
|
| Motor Torque | Motor (MG2) torque execution value | Min.: -4096.00 Nm, Max.: 4095.87 Nm | After full-load acceleration with power switch on (READY) and engine stopped: Within +/-20% of target motor (MG2) torque |
|
| Request Motor Regenerative Brake Torque | Requested motor (MG2) regenerative braking torque | Min.: -4096.00 Nm, Max.: 4095.87 Nm | While braking: Varies depending on vehicle operation conditions |
When regenerative braking is being performed, current flows from the motor (MG2) to charge the HV battery and braking torque is generated.
|
| Motor Regenerate Brake Execution Torque | Motor (MG2) regenerative braking execution torque | Min.: -4096.00 Nm, Max.: 4095.87 Nm | While braking: Varies depending on vehicle operation conditions |
|
| Generator Temperature | Generator (MG1) temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 25°C (77°F) While driving: Varies depending on vehicle operating conditions |
- |
| Generator Temperature Sensor Voltage | Generator (MG1) temperature sensor voltage | Min.: 0 V, Max.: 4.99 V | - | - |
| Generator Temperature just after IG ON | Generator (MG1) temperature soon after power switch on (IG) | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Generator Maximum Temperature | Maximum generator (MG1) temperature after power switch turned on (IG) in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Motor Temperature | Motor (MG2) temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 25°C (77°F) While driving: Varies depending on vehicle operating conditions |
- |
| Motor Temperature Sensor Voltage | Motor (MG2) temperature sensor voltage | Min.: 0 V, Max.: 4.99 V | - | - |
| Motor Temperature just after IG ON | Motor (MG2) temperature soon after power switch on (IG) | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Motor Maximum Temperature | Maximum motor (MG2) temperature after power switch turned on (IG) in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Generator Inverter Calculated Temperature | Generator inverter temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 8 to 35°C (46 to 95°F) While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F) |
Inverter with converter assembly |
| Generator Inverter Calculated Temperature just after IG ON | Generator inverter temperature soon after power switch on (IG) | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Generator Inverter Calculated Maximum Temperature | Maximum generator inverter temperature after power switch turned on (IG) in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Motor Inverter Temperature | Motor inverter temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 8 to 35°C (46 to 95°F) While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F) |
Inverter with converter assembly |
| Motor Inverter Temperature just after IG ON | Motor inverter temperature soon after power switch on (IG) | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Motor Inverter Maximum Temperature | Maximum motor inverter temperature after power switch turned on (IG) in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Boosting Converter Temperature (Upper) | Boost converter temperature (upper) | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 8 to 35°C (46 to 95°F) While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F) |
Inverter with converter assembly |
| Boosting Converter Temperature (Lower) | Boost converter temperature (lower) | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 8 to 35°C (46 to 95°F) While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F) |
Inverter with converter assembly |
| Boosting Converter Temperature just after IG ON | Boost converter temperature soon after power switch on (IG) | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Boosting Converter Maximum Temperature | Maximum converter temperature after power switch turned on (IG) in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Generator Inverter Operation Request | Generator inverter operation request | Shutdown / Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement | - | - |
| Generator Inverter Fail | Generator inverter stopped | ON or OFF | Generator inverter stopped: ON Normal: OFF |
- |
| Generator Inverter Shutdown Status | Generator inverter shutdown status | Awake or Shutdown | Generator inverter shutdown: Shutdown Normal: Awake |
- |
| Motor Inverter Operation Request | Motor inverter operation request | Shutdown / Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement | - | - |
| Motor Inverter Fail | Motor inverter stopped | ON or OFF | Motor inverter stopped: ON Normal: OFF |
- |
| Motor Inverter Shutdown Status | Motor inverter shutdown status | Awake or Shutdown | Motor inverter shutdown: Shutdown Normal: Awake |
- |
| Boosting Converter Operation Request | Boost converter operation request | Normal / Boosting Stop / Upper Arm ON / Maximum Boosting / Output Torque / Upper Arm Lowering | - | - |
| Boosting Converter Fail | Boost converter stopped | ON or OFF | Boost converter stopped: ON Normal: OFF |
- |
| Boosting Converter Shutdown Status | Boost converter shutdown status | Awake or Shutdown | Boost converter shutdown: Shutdown Normal: Awake |
- |
| Generator Carrier Frequency | Generator carrier frequency | 0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode | - | - |
| Generator Control Mode | Generator (MG1) control mode | Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode | PWM: Sine Wave Variable PWM: Overmodulation Rectangular wave: Square Wave |
- |
| Motor Carrier Frequency | Motor (MG2) carrier frequency | 0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode | - | - |
| Motor Control Mode | Motor (MG2) control mode | Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode | PWM: Sine Wave Variable PWM: Overmodulation Rectangular wave: Square Wave |
- |
| Boosting Converter Carrier Frequency | Boost converter signal carrier frequency | 9.55 kHz / 9.13 kHz / 8.71 kHz / 8.29 kHz / 7.87 kHz / 7.45 kHz / 4.8 kHz | - | - |
| VL-Voltage before Boosting | High voltage before it is boosted | Min.: 0.0 V, Max.: 32767.5 V | Power switch on (READY): Practically the same as the HV battery voltage |
|
| VH-Voltage after Boosting | High voltage after it is boosted | Min.: 0.0 V, Max.: 32767.5 V | Engine revving up with shift lever in P: After boosted voltage to below approximately 600 V |
Inverter with converter assembly |
| Boost Ratio | Boost converter boost ratio | Min.: 0.0%, Max.: 100.0% | - | Inverter with converter assembly |
| V Phase Generator Current | V phase generator current | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| W Phase Generator Current | W phase generator current | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| V Phase Motor Current | V phase motor current | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| W Phase Motor Current | W phase motor current | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| DC/DC Converter Operation Status | DC/DC converter operating state | During Stop Request to MG ECU by HV ECU / Stop / Normal Operation | - | - |
| DC/DC Converter Output Voltage Control Mode | DC/DC converter output voltage control mode | Normal / Forced Output / Fuel Modification / Very Low Temperature / Applied Voltage for Light / Charging (Dark Current) / Charging (Parking) | - | - |
| DC/DC Converter Drive Request | DC/DC converter operation request | Stop Request / Drive Request / Abnormal Detection Signal Check Request | - | - |
| Target DC/DC Converter Voltage | DC/DC converter target step-down voltage | Min.: 0.0 V, Max.: 25.5 V | - | - |
| Inverter Coolant Water Temperature | Inverter coolant temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Cold start→Fully warmed up: Gradually rises System operating normally: Controlled at 65°C (149°F) or less |
|
| Inverter Water Pump | Inverter water pump assembly status | ON or OFF | Inverter water pump assembly is operating: ON |
|
| Inverter Water Pump Duty Ratio | Inverter water pump motor driver request duty | Min.: 0.0%, Max.: 399.9% | Power switch on (READY): 62.50 to 93.75% |
Hybrid vehicle control ECU |
| Inverter Water Pump Revolution | Inverter water pump assembly speed | Min.: 0 rpm, Max.: 65535 rpm | Power switch on (READY): 1000 to 9300 rpm |
When the inverter water pump assembly is not operating: Lower than 200 rpm |
| Overvoltage Input to Inverter | Overvoltage detection into inverter | ON or OFF | Overvoltage is detected into inverter: ON Normal: OFF |
- |
| Inverter Emergency Shutdown (Main CPU) | Inverter emergency shutdown | ON or OFF | Inverter emergency shutdown: ON Normal: OFF |
- |
| Inverter Emergency Shutdown (Sub CPU) | Inverter emergency shutdown | ON or OFF | Inverter emergency shutdown: ON Normal: OFF |
- |
| Overvoltage Input to Boosting Converter | Overvoltage detection into boost converter | ON or OFF | Overvoltage is detected into boost converter: ON Normal: OFF |
- |
| Target Motor/Generator Cooling Oil Pump Motor Duty | Oil pump with motor assembly request duty | Min.: 0.0%, Max.: 100.0% | OIL PMP relay ON: 15 to 85 % |
- |
| Motor/Generator Cooling Oil Pump Motor Revolution | Oil pump with motor assembly speed | Min.: 0 rpm, Max.: 65535 rpm | OIL PMP relay ON: 0 to 7000 rpm |
- |
| Motor/Generator Cooling Oil Pump Motor Power Relay Request | OIL PMP relay operation request | ON or OFF | OIL PMP relay operating: ON OIL PMP relay not operating: OFF |
OPM2 terminal |
| Hybrid Battery SOC | HV battery state of charge Primary calculated from charging and discharging amperage |
Min.: 0.0%, Max.: 100.0% | Constant: 0.0 to 100.0% |
|
| Hybrid Battery SOC of Immediately after IG ON | HV battery state of charge soon after power switch on (IG) | Min.: 0.0%, Max.: 127.5% | - | - |
| Hybrid Battery Maximum SOC | Maximum SOC after power switch turned on (IG) in current trip | Min.: 0.0%, Max.: 127.5% | - | - |
| Hybrid Battery Minimum SOC | Minimum SOC after power switch turned on (IG) in current trip | Min.: 0.0%, Max.: 127.5% | - | - |
| Hybrid Battery Voltage | HV battery voltage | Min.: 0.00 V, Max.: 1023.98 V | Power switch on (READY): 285.00 to 380.00 V |
|
| Hybrid Battery Current | HV battery current | Min.: -327.68 A, Max.: 327.67 A | Power switch on (IG): -4.00 to 4.00 A |
|
| Hybrid Battery Current for Driving Control | Hybrid battery current for driving control | Min.: -327.68 A, Max.: 327.67 A | - |
|
| Hybrid Battery Charging Power | HV battery charging power | Min.: -327.68 kW, Max.: 327.67 kW | - | - |
| Hybrid Battery Control Status on Thermal Keeping and Charging | HV battery heating / charging state | Unoperated / Charging / Thermal Keeping / Thermal Keeping and Charging | - | - |
| Charging Voltage for Hybrid Battery | HV battery charging voltage (VCHG sensor value) | Min.: 0.0 V, Max.: 6553.5 V | - | - |
| Hybrid Battery Charging and Discharging Permission Status with Hybrid Battery Thermal Keep | HV battery charge / discharge state during temperature adjustment | OK / NG / Charging OK and Discharging NG / Charging NG and Discharging OK | - | - |
| Hybrid Battery Temperature when Charging Start | HV Battery temperature when charging start | Min.: -32768°C (-58950°F), Max.: 32767°C (59012°F) | - | - |
| Hybrid Battery Maximum Temperature | HV battery highest temperature during current trip | Min.: -50.0°C (-58.0°F), Max.: 205.9°C (402.6°F) | - | - |
| Hybrid Battery Minimum Temperature | HV battery lowest temperature during current trip | Min.: -50.0°C (-58.0°F), Max.: 205.9°C (402.6°F) | - | - |
| Hybrid Battery Cooling Fan Low Speed Request | Battery cooling blower assembly Lo speed requested | ON or OFF | Constant: ON or OFF |
- |
| Hybrid Battery Cooling Necessity before Charging | HV battery cooling necessary before charging | ON or OFF | - | - |
| History of Hybrid Battery Cooling Cancel | HV battery cooling suspended | None or Done | - | - |
| Short Wave Highest Value Level | Waveform voltage level in abnormal insulation detection circuit in battery ECU assembly | Not Judge / Normal / Insulation Lower LV2 / Insulation Lower LV3 | Judgment not completed: Not Judge Normal: Normal condition Medium low level: Insulation Lower LV2 Severe low level: Insulation Lower LV3 |
High voltage circuit |
| Insulation Resistance Division Check Completion using MG Inv | Insulation Resistance Division Check Completion using MG inv | Not Complete / Complete | Decreased insulation resistance judgment for motor and generator inverter has completed: Complete |
After turning the power switch from on (READY) to off, compare the value of Data List item "Short Wave Highest Value Level" before and after the motor and generator inverter are shut down. |
| Insulation Resistance Division Check Completion using A/C Inv | Insulation resistance division check completion using A/C inv | Not Complete / Complete | Decreased insulation resistance judgment for the air conditioning inverter has completed: Complete |
Check the value of Data List item "Short Wave Highest Value Level" before and after the air conditioning inverter is shut down. |
| Insulation Resistance Division Check Completion using SMR | Insulation resistance division check completion using SMR | Not Complete / Complete | Decreased insulation resistance judgment for the system main relays has completed: Complete |
Check the value of Data List item "Short Wave Highest Value Level" before and after the system main relays are turned off. |
| Short Wave Highest Value Availability just after MG Inv On/Off | Short wave highest value availability just after MG inv on/off | No or Yes | The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after the motor and generator inverter are turned on/off: No |
- |
| Short Wave Highest Value Availability just after A/C Inv On/Off | Short wave highest value availability just after A/C inv on/off | No or Yes | The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after air conditioning inverter turned on/off. No |
- |
| Short Wave Highest Value Availability just after SMR On/Off | Short wave highest value availability just after SMR on/off | No or Yes | The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after system main relays turned on/off. No |
- |
| Immobiliser Communication | Immobiliser communication line status | ON or OFF | Power switch on (IG): ON Immobiliser communication line malfunction: OFF |
- |
| Permit Start by Immobiliser | Status of starting permission by immobiliser (immobiliser to hybrid vehicle control ECU) | No Judgment / OK / NG | - | - |
| Auxiliary Battery Voltage | Auxiliary battery voltage | Min.: 0.00 V, Max.: 16.00 V | Always: 11.00 to 15.00 V |
When power switch on (READY): approx. 12.5 to 15.0 V. When power switch on (IG): same as auxiliary battery voltage (approx. 12V). If the voltage becomes 11 V or less when the power switch is on (READY), the hybrid vehicle control ECU stores inverter with converter assembly DTCs. If the voltage becomes 9.5 V or less, the power switch will not be able to be turned on (READY).
|
| Auxiliary Battery Current | Auxiliary battery current | Min.: -125.00 A, Max.: 124.99 A | - | - |
| Smoothed Value of Auxiliary Battery Temperature | Smoothed value of auxiliary battery temperature | Min.: -40.0°C (-40.0°F), Max.: 6513.5°C (11756.3°F) | - | - |
| Auxiliary Battery Voltage Low Times | Auxiliary battery voltage low times | Min.: 0, Max.: 255 | - | - |
| Auxiliary Battery Voltage at Low Voltage Checking Initiation | Voltage of auxiliary battery voltage low judgment | Min.: 0.00 V, Max.: 20.00 V | - | - |
| Auxiliary Battery Charging Integrated Current | Cumulative battery charging integrated current value since vehicle was built | Min.: 0.0 Ah, Max.: 429496729.5 Ah | - | - |
| Auxiliary Battery Discharging Integrated Current | Cumulative battery discharging integrated current value since vehicle was built | Min.: 0.0 Ah, Max.: 429496729.5 Ah | - | - |
| Auxiliary Battery Capacity after IG ON | Auxiliary battery capacity after IG ON | Min.: -128 Ah, Max.: 127 Ah | - | - |
| Auxiliary Battery Capacity after IG OFF | Auxiliary battery capacity after IG OFF | Min.: -128 Ah, Max.: 127 Ah | - | - |
| Integrated Ready ON Time | Cumulative time power switch has been on (READY) since vehicle was built | Min.: 0 hour, Max.: 65535 hour | - | - |
| Number of Long Term Leaving with IG OFF | Number of times power switch not changed from off for long period of time (1440 hours (60 days)) | Min.: 0, Max.: 255 | - | - |
| Auxiliary Battery Integrated Thermal Load | Cumulative auxiliary battery thermal load since vehicle was built | Min.: 0, Max.: 4294967295 | - | - |
| Auxiliary Battery Voltage Low Status by Hybrid Control ECU | Auxiliary battery voltage drop | ON or OFF | - | - |
| Auxiliary Battery Voltage Low Status from Hybrid Battery Control ECU | Existence of auxiliary battery voltage drop signal (from battery ECU) | ON or OFF | - | - |
| Auxiliary Battery Voltage Low Status from Plug-in Control ECU | Existence of auxiliary battery voltage drop signal (from electric vehicle charger assembly) | ON or OFF | - | - |
| Auxiliary Battery Voltage Low Status from Solar Charging Control ECU | Existence of auxiliary battery voltage drop signal (from solar energy control unit)*1 | ON or OFF | - | - |
| Auxiliary Battery Supply Power during AC Charging | Estimated power supplied to auxiliary battery during plug-in charging | Min.: -327.68 kW, Max.: 327.67 kW | - | - |
| Total Distance Indicated after Long Term Leaving with IG OFF (1st) | Cumulative distance before 1st long term power switch off period of time (1440 hours (60 days)) | Min.: 0, Max: 131070 km | - | - |
| Total Distance Indicated after Long Term Leaving with IG OFF (2nd) | Cumulative distance before 2nd long term power switch off period of time (1440 hours (60 days)) | Min.: 0, Max: 131070 km | - | - |
| Total Distance Indicated after Long Term Leaving with IG OFF (3rd) | Cumulative distance before 3rd long term power switch off period of time (1440 hours (60 days)) | Min.: 0, Max: 131070 km | - | - |
| Time of Long Term Leaving with IG OFF (1st) | Number of days of 1st long term power switch off period of time (1440 hours (60 days)) | Min.: 0 day, Max.: 255 day | - | - |
| Time of Long Term Leaving with IG OFF (2nd) | Number of days of 2nd long term power switch off period of time (1440 hours (60 days)) | Min.: 0 day, Max.: 255 day | - | - |
| Time of Long Term Leaving with IG OFF (3rd) | Number of days of 3rd long term power switch off period of time (1440 hours (60 days)) | Min.: 0 day, Max.: 255 day | - | - |
| Auxiliary Battery Average Current during IG OFF 1 Trip before | Average auxiliary battery current when power switch off 1 trip before | Min.: -32.768 A, Max: 32.767 A | - | - |
| Auxiliary Battery Average Current during IG OFF 2 Trip before | Average auxiliary battery current when power switch off 2 trip before | Min.: -32.768 A, Max: 32.767 A | - | - |
| Auxiliary Battery Average Current during IG OFF 3 Trip before | Average auxiliary battery current when power switch off 3 trip before | Min.: -32.768 A, Max: 32.767 A | - | - |
| Auxiliary Battery Average Current during IG OFF 4 Trip before | Average auxiliary battery current when power switch off 4 trip before | Min.: -32.768 A, Max: 32.767 A | - | - |
| Auxiliary Battery Average Current during IG OFF 5 Trip before | Average auxiliary battery current when power switch off 5 trip before | Min.: -32.768 A, Max: 32.767 A | - | - |
| Total Distance Up to 1 Trip before | Cumulative distance traveled 1 trip before | Min.: 0, Max: 131070 km | - | - |
| Total Distance Up to 2 Trip before | Cumulative distance traveled 2 trip before | Min.: 0, Max: 131070 km | - | - |
| Total Distance Up to 3 Trip before | Cumulative distance traveled 3 trip before | Min.: 0, Max: 131070 km | - | - |
| Total Distance Up to 4 Trip before | Cumulative distance traveled 4 trip before | Min.: 0, Max: 131070 km | - | - |
| Total Distance Up to 5 Trip before | Cumulative distance traveled 5 trip before | Min.: 0, Max: 131070 km | - | - |
| IG OFF Time before 1 trip | Number of days power switch was off 1 trip before | Min.: 0 day, Max.: 255 day | - | - |
| IG OFF Time before 2 trip | Number of days power switch was off 2 trip before | Min.: 0 day, Max.: 255 day | - | - |
| IG OFF Time before 3 trip | Number of days power switch was off 3 trip before | Min.: 0 day, Max.: 255 day | - | - |
| IG OFF Time before 4 trip | Number of days power switch was off 4 trip before | Min.: 0 day, Max.: 255 day | - | - |
| IG OFF Time before 5 trip | Number of days power switch was off 5 trip before | Min.: 0 day, Max.: 255 day | - | - |
| IG ON Time Up to 1 trip before | Time power switch was on (IG) 1 trip before | Min.: 0 min, Max.: 510 min | - | - |
| IG ON Time Up to 2 trip before | Time power switch was on (IG) 2 trip before | Min.: 0 min, Max.: 510 min | - | - |
| IG ON Time Up to 3 trip before | Time power switch was on (IG) 3 trip before | Min.: 0 min, Max.: 510 min | - | - |
| IG ON Time Up to 4 trip before | Time power switch was on (IG) 4 trip before | Min.: 0 min, Max.: 510 min | - | - |
| IG ON Time Up to 5 trip before | Time power switch was on (IG) 5 trip before | Min.: 0 min, Max.: 510 min | - | - |
| Ready ON Time Up to 1 trip before | Time power switch was on (READY) 1 trip before | Min.: 0 min, Max.: 510 min | - | - |
| Ready ON Time Up to 2 trip before | Time power switch was on (READY) 2 trip before | Min.: 0 min, Max.: 510 min | - | - |
| Ready ON Time Up to 3 trip before | Time power switch was on (READY) 3 trip before | Min.: 0 min, Max.: 510 min | - | - |
| Ready ON Time Up to 4 trip before | Time power switch was on (READY) 4 trip before | Min.: 0 min, Max.: 510 min | - | - |
| Ready ON Time Up to 5 trip before | Time power switch was on (READY) 5 trip before | Min.: 0 min, Max.: 510 min | - | - |
| P Control Request Status | Shift control actuator assembly operation request | No Request / Lock(Normal) / Unlock(Normal) / Lock(Abnormal) / Unlock(Abnormal) | - | - |
| P Control Status | Park (P) shift state status | Lock Position (Normal) / Lock Position (Abnormal) / Indefinite Position (Normal) / Indefinite Position (Abnormal) / Unlock Position (Normal) / Unlock Position (Abnormal) / Lock Position (Normal) / Lock Position (Abnormal) / Indefinite Position (Normal) / Indefinite Position (Abnormal) / Unlock Position (Normal) / Unlock Position (Abnormal) | - | - |
| Parking Lock Motor Current Sensor Voltage | Shift control actuator assembly sensor voltage | Min: 0.00 V, Max: 4.99 V | - | - |
| W Phase Parking Lock Motor Current-Carrying Status | W phase current-carrying status | OFF or ON | W phase current flows: ON W phase current does not flow: OFF |
Shift control actuator assembly [parking lock motor (MWA)] signal circuit |
| V Phase Parking Lock Motor Current-Carrying Status | V phase current-carrying status | OFF or ON | V phase current flows: ON V phase current does not flow: OFF |
Shift control actuator assembly [parking lock motor (MVA)] signal circuit |
| U Phase Parking Lock Motor Current-Carrying Status | U phase current-carrying status | OFF or ON | U phase current flows: ON U phase current does not flow: OFF |
Shift control actuator assembly [parking lock motor (MUA)] signal circuit |
| W Phase Parking Lock Motor Terminal Voltage | Shift control actuator assembly (parking lock motor (W phase terminal voltage)) AD voltage (ECU recognized value) | 0 to 4.99 V | Power switch on (IG): 0 to 3.5 V |
Shift control actuator assembly [parking lock motor (MWA)] signal circuit |
| V Phase Parking Lock Motor Terminal Voltage | Shift control actuator assembly (parking lock motor (V phase terminal voltage)) AD voltage (ECU recognized value) | 0 to 4.99 V | Power switch on (IG): 0 to 3.5 V |
Shift control actuator assembly [parking lock motor (MVA)] signal circuit |
| U Phase Parking Lock Motor Terminal Voltage | Shift control actuator assembly (parking lock motor (U phase terminal voltage)) AD voltage (ECU recognized value) | 0 to 4.99 V | Power switch on (IG): 0 to 3.5 V |
Shift control actuator assembly [parking lock motor (MUA)] signal circuit |
| Relay Cut Signal of Parking Lock Motor Power for Hybrid Control System | No. 1 integration relay (P-CON relay) state of control by hybrid vehicle control ECU | ON or OFF | - | - |
| Parking Lock Motor Relay Status for Transmission Control System | No. 1 integration relay (P-CON relay) state | ON or OFF | - | - |
| Abnormality Informing Status | Malfunction information status | ON or OFF | ON: Malfunction occurs in this system OFF: Malfunction does not occur in this system |
Hybrid vehicle control ECU |
| P Position Switch Indicator | P position switch indicator illumination status | OFF or ON | Park (P) selected: ON A shift state other than park (P) selected: OFF (When normal) (May go off during malfunction) |
- |
| P Position Switch Indicator Dimming Request | P position switch indicator dim signal status | Non-dimming or Dimming | - | - |
| BATT Voltage for Transmission Control System | +B voltage value | Min: 0.00 V, Max: 79.99 V | Power switch on (IG): 8.00 to 16.00 V |
+B signal circuit |
| IG Voltage for Transmission Control System | IG voltage value | Min: 0.00 V, Max: 79.99 V | Power switch on (IG): 8.00 to 16.00 V |
IG signal circuit |
| Lock Position Learning Value | Learned value of lock position | -32768 to 32767 | - | - |
| Unlock Position Learning Value | Learned value of unlock position | -32768 to 32767 | - | - |
| Complete of Learn Unlock Position | Completion of unlock position learning | OK or NG | Power switch on (IG), Park (P) selected → Neutral (N) selected and number of trips after learning is less than 3 or power switch on (IG) and number of trips after learning is 3 or more: OK Power switch on (IG), a shift state other than Park (P) has not been selected and number of trips after learning is less than 3: NG |
|
| Complete of Detect Unlock Position | Completion of detecting unlock position | OK or NG | Power switch on (IG), Park (P) selected → Neutral (N) selected and number of trips after learning is less than 3: OK Power switch on (IG) and number of trips after learning is 3 or more: NG |
- |
| Complete of Learn Lock Position | Completion of lock position learning | OK or NG | Power switch on (IG): OK |
- |
| Complete of Detect Lock Position | Completion of detecting lock position | OK or NG | Power switch on (IG): OK |
- |
| Complete of Initially Drive Parking Lock Control | Initial drive control completed | OK or NG | Power switch on (IG): OK |
- |
| Auxiliary Battery Voltage Low History (P Lock Operate) | History of low voltage during shift control actuator assembly operation | OFF or ON | - | - |
| Number of Trip after Auxiliary Battery Voltage Low (P Lock Operate) | Number of trips since low voltage detected during shift control actuator assembly operation | Min: 0, Max: 255 | - | - |
| Effective Status of Braking Torque | Regenerative braking status | Not Available or Available | - | - |
| P Position Automatic Change Request | P position automatic change request | OFF or ON | - | - |
| Shift P Auto Change by Cruise Control Trigger Counter | Number of times shift state changed to park (P) automatically by brake hold prevention function of dynamic radar cruise control system (w/ full-speed range following function) | Min: 0, Max: 255 | - | - |
| Number of Release Shift P Operation during Charging or External Power Supply | Number of times park (P) release operation performed during plug-in charging | Min.: 0, Max.: 255 | - | - |
| Target Charging Power | Electric vehicle charger assembly requested power for charging | Min.: -327.68 kW, Max.: 327.67 kW | - | - |
| Charging Status | Hybrid vehicle control ECU recognized charging state | Stop / Preparing / Charging / Process to Stop | - | - |
| Elapsed Time after Charging Status Transition | Time elapsed since charging started | Min.: 0 ms, Max.: 655350 ms | - | - |
| Number of Charging (Same System Voltage) | Number of charging operations performed using same power supply voltage (above a certain number of times) | Min.: 0, Max.: 255 | - | - |
| Charging Control Signal Status | Charge control signal (CPLT) oscillation state | None / Normal / Temporarily Nonusable / Nonusable / Stuck Low / Stuck High | - | - |
| Charger Operation Status | Electric vehicle charger assembly state output to hybrid vehicle control ECU | Stand by / Ready / Stop | - | - |
| Charger Start Request by Hybrid Control ECU | Electric vehicle charger assembly activation request (from hybrid vehicle control ECU) | ON or OFF | - | - |
| Charger Input Power | Electric vehicle charger assembly input power | Min.: 0 W, Max.: 327675 W | - | - |
| Sub DC/DC Converter Supply Status (for Charging) | Sub DC/DC converter state | OFF / ON / Abnormal | - | - |
| Sub DC/DC Converter Start Request (for Charging) | Sub DC/DC converter activation request | ON or OFF | - | - |
| Target Sub DC/DC Converter Voltage (for Charging) | Sub DC/DC converter target output voltage | Min: 0.00 V, Max: 79.99 V | - | - |
| Charge Canceled by Hybrid Battery WIN Low Trigger Counter | Number of times plug-in charging suspended due to drop in WIN of HV battery | Min.: 0, Max.: 65535 | - | - |
| Charge Canceled by Auxiliary Battery Voltage Low Trigger Counter | Number of times plug-in charging suspended due to drop in auxiliary battery voltage | Min.: 0, Max.: 65535 | - | - |
| Charge Canceled by Charging System Trigger Counter | Number of times plug-in charging suspended due to charging system malfunction | Min.: 0, Max.: 65535 | - | - |
| Charger Power Supply Voltage Decreasing History during Charging | Cumulative insufficient power exceeded threshold | ON or OFF | - | - |
| Charging Power Save Mode History by Charger Temperature High | Plug-in charging restricted due to overheating of charging station | ON or OFF | - | - |
| WIN Low History during Charging | Input power dropped during plug-in charging | ON or OFF | - | - |
| Auxiliary Battery Increasing Electrical Load History during Charging | Auxiliary battery load exceeded threshold during plug-in charging | ON or OFF | - | - |
| AC Input Current | Charging current sensor value (from charger inlet) | Min.: 0.0 A, Max.: 25.5 A | - | - |
| AC Charger Rated Power | Charging station nominal supply power | Min.: -327.68 kW, Max.: 327.67 kW | - | - |
| AC Charging Inlet Connect Status | Connection state or availability of components connected to plug-in charger inlet | None / Connecting Charging Connector / Temporarily Nonusable / Nonusable / Not Connect / Connector Not Engaged Properly Status / Connecting External Power Supply Connector | - | - |
| AC Charging Input Minimum Voltage History | Minimum voltage input during plug-in charging history | Min.: -3276.8 V, Max.: 3276.7 V | - | - |
| AC Charging Negative Relay Drive Request | Commanded state of CHRG | ON or OFF | Battery ECU assembly requesting CHRG relay operation: ON |
- |
| AC Charging Positive Relay Drive Request | Commanded state of CHRB | ON or OFF | Battery ECU assembly requesting CHRB relay operation: ON |
- |
| AC Charging Precharge Relay Drive Request | Commanded state of CHRP | ON or OFF | Battery ECU assembly requesting CHRP relay operation: ON |
- |
| AC Charging Negative Relay Status | Operating state of CHRG | ON or OFF | CHRG relay operating: ON |
- |
| AC Charging Positive Relay Status | Operating state of CHRB | ON or OFF | CHRB relay operating: ON |
- |
| AC Charging Precharge Relay Status | Operating state of CHRP | ON or OFF | CHRP relay operating: ON |
- |
| Operation to Raise AC Charger Rated Current | Charging station maximum current supply Increased | ON or OFF | - | - |
| Operation to Lower AC Charger Rated Current | Charging station maximum current supply decreased | ON or OFF | - | - |
| DC Quick Charging Lid Status | Charging lid status | No Judgment / Close / Open | - | - |
| Solar Charging Permission Signal by Main CPU | Solar charging permission signal from hybrid vehicle control ECU (main CPU)*1 | NG or OK | - | - |
| Solar Charging Permission Signal by Sub CPU | Solar charging permission signal from hybrid vehicle control ECU (sub CPU)*1 | NG or OK | - | - |
| Solar Charging Permission Answerback Signal from Solar Charging Control ECU | Solar charging permission answerback signal from solar charging control ECU*1 | NG or OK | - | - |
| Solar Charge Hybrid Battery DC/DC Converter Drive Request | Solar charging system HV battery DC/DC boost converter operation request*1 | ON or OFF | - | - |
| Solar Charge Hybrid Battery DC/DC Converter Input Power | Solar charging system HV battery DC/DC boost converter input power*1 | Min: 0 W, Max: 65535 W | - | - |
| Smoothed Value of Solar Charge Hybrid Battery DC/DC Converter Input Voltage | Smoothed value of solar charging system HV battery DC/DC boost converter input voltage*1 | Min: 0 V, Max: 6553.5 V | - | - |
| Shift P Operation during Running Trigger Counter | Number of times P position switch (transmission shift main switch) operated while driving | Min: 0, Max: 255 | - | - |
| Shift P Operation before Vehicle Stop Trigger Counter | Number of times shift state was not changed to park (P) when P position switch (transmission shift main switch) operated before vehicle stopped | Min: 0, Max: 255 | - | - |
| Shift P Operation during Other than Shift P Operation Trigger Counter | Number of times P position switch (transmission shift main switch) operated when shift lever operated | Min: 0, Max: 255 | - | - |
| Auto Change to Shift Position P Cancel Trigger Counter | Number of times P position automatic change function did not operate | Min: 0, Max: 255 | - | - |
| Voltage Low for Shift Control System Trigger Counter | Number of times shift control system did not operate due to low voltage | Min: 0, Max: 255 | - | - |
| Shift Operation when Auxiliary Battery Voltage Low Trigger Counter | Number of times shift state change attempted with low auxiliary battery voltage | Min: 0, Max: 255 | - | - |
| Consecutive Shift Change between Shift P and Other than Shift P in Short Times Trigger Counter | Number of times shift state was attempted to be changed to and from park (P) within short period of time | Min: 0, Max: 255 | - | - |
| Shift Operation during Ready Indicator Blinking Trigger Counter | Number of times shift state was attempted to be changed from park (P) with READY indicator blinking | Min: 0, Max: 255 | - | - |
| Shift R/D/B(S) Operation during Ready OFF Trigger Counter | Number of times shift state was attempted to be changed to (R), (D) or (B) with power switch on (IG) | Min: 0, Max: 255 | - | - |
| Shift Operation without Depressing Brake from Shift Position P Trigger Counter | Number of times shift state was attempted to be changed from park (P) with brake pedal not depressed | Min: 0, Max: 255 | - | - |
| Shift Operation during Accelerator & Brake Depress Trigger Counter | Number of times shift state was attempted to be changed from park (P) with READY indicator light illuminated and accelerator and brake pedals depressed | Min: 0, Max: 255 | - | - |
| Shift B(S) Operation from Shift Position P/N Trigger Counter | Number of times shift state was attempted to be changed from (P) or (N) to (B) | Min: 0, Max: 255 | - | - |
| Shift B(S) Operation from Shift Position R Trigger Counter | Number of times shift state was attempted to be changed from (R) to (B) | Min: 0, Max: 255 | - | - |
| Shift D Operation during Backward Movement Trigger Counter | Number of times shift state was attempted to be changed to drive (D) while backing up | Min: 0, Max: 255 | - | - |
| Shift R Operation during Forward Movement Trigger Counter | Number of times shift state was attempted to be changed to reverse (R) while driving forward | Min: 0, Max: 255 | - | - |
| Shift R/D Operation during Ready OFF Trigger Counter | Number of times shift state was changed to neutral (N) when shift lever held in R or D with power switch on (IG) | Min: 0, Max: 255 | - | - |
| Shift N Operation during Running Trigger Counter | Number of times shift state was changed to neutral (N) by holding shift lever in N while driving | Min: 0, Max: 255 | - | - |
| Quick Shift Operation to Shift Position N during Running Trigger Counter | Number of times shift state was changed to neutral (N) when shift lever not held in N while driving | Min: 0, Max: 255 | - | - |
| Shift N Change by Busy Shift Trigger Counter | Number of times shift state was changed to neutral (N) by moving shift lever to R, D and/or N repeatedly within short period of time | Min: 0, Max: 255 | - | - |
| Shift N Operation on The Way Back to Home Position after Shift D/R Operation Trigger Counter | Number of times shift state was changed to neutral (N) when shift lever was returning from R or D | Min: 0, Max: 255 | - | - |
| Shift R Operation on The Way Back to Home Position after Shift D Operation Trigger Counter | Number of times shift state was changed to reverse (R) when shift lever was returning from D | Min: 0, Max: 255 | - | - |
| Shift D Operation on The Way Back to Home Position after Shift R Operation Trigger Counter | Number of times shift state was changed to drive (D) when shift lever was returning from R | Min: 0, Max: 255 | - | - |
| Shift N Operation at Short Times during Low Speed/Stopping Trigger Counter | Number of times shift state was attempted to be changed to neutral (N) without holding shift lever in N for a long enough time when driving at low speed or stopped | Min: 0, Max: 255 | - | - |
*1: w/ Solar charging system
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Note
It is necessary to use caution, because if the tester DLC connector becomes disconnected or if a communication error occurs during an Active Test, the vehicle could become inoperative (the READY indicator may go off).
After performing the Active Test, turn the power switch off before proceeding to the next step.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Hybrid Control / Active Test.
According to the display on the GTS perform the appropriate Active Test.
| Tester Display | Measurement Item | Control Range | Restrict Condition | Diagnostic Note |
|---|---|---|---|---|
| Compression Test | To crank the engine continuously in order to measure the compression*1 | ON / OFF | Power switch on (IG), HV system normal, not in cranking mode, and other Active Tests not being done |
[Current Value] Not Active or Active |
| Activate the Inverter Water Pump | To activate the inverter water pump assembly continuously | ON / OFF | Power switch on (IG), HV system normal, not in maintenance mode, and other Active Tests not being performed, auxiliary battery voltage is 9.5 V or more |
|
| Connect the TC and TE1 | Batch display of warnings on combination meter assembly | ON / OFF | Power switch on (IG) |
|
| Control the Motor/Generator Cooling Oil Pump | Operate the oil pump with motor assembly | 0 to 100%*2 | Power switch on (IG) or (READY), engine stopped, HV system normal, after warming up |
[Current Value] Not Active / Active / Complete / Abort |
Note
*1: The GTS will display a communication error and the vehicle's READY indicator will turn off when the Active Test is completed. If the GTS will be used on the vehicle again, turn the power switch off and then on (READY) again to restart the GTS.
*2: The active test is not performed when the Duty ratio 50 % or lower or 95 % or higher, or the ambient temperature is 10 °C (50 °F) or lower.