FREEZE FRAME DATA
Tech Tips
The hybrid vehicle control ECU records vehicle and driving condition information as freeze frame data the moment a DTC is stored. It can be used for estimating or duplicating the vehicle conditions that were present when the malfunction occurred.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Select a DTC in order to display its freeze frame data.
Check the freeze frame information recorded with the DTC.
| Tester Display | Measurement Item | Range |
|---|---|---|
| Vehicle Speed | Vehicle speed | Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) |
| Target Engine Power | Target engine power | Min.: 0 W, Max.: 655350 W |
| Execute Engine Power | Execute engine power | Min.: 0 W, Max.: 655350 W |
| Target Engine Revolution | Target engine revolution | Min.: 0 rpm, Max.: 32767 rpm |
| Engine Speed | Engine speed | - |
| Calculate Load | Calculate load | Min.: 0.00%, Max.: 100.00% |
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Starter Switch Signal | Starter ON / OFF signal | ON or OFF |
| Engine Idling Request | Engine idling request | ON or OFF |
| Engine Start Request (A/C) | Engine idling request from air conditioning amplifier assembly | ON or OFF |
| Engine Start Request (Engine Warm-up) | Engine idling request to warm up engine | ON or OFF |
| Engine Start Request (Hybrid Battery Charging) | Engine idling request to charge HV battery | ON or OFF |
| Engine Mode | Engine status | Stop / Stop Process / Startup Process / Running |
| Engine Run Time | Elapsed time after starting engine | Min.: 0 sec, Max.: 65535 sec |
| Engine Stop Request | Engine stop request | ON or OFF |
| Engine Stop F/C Status | Engine fuel cut status | ON or OFF |
| Lack of Fuel | Lack of fuel | ON or OFF |
| Accelerator Position | Accelerator pedal depressed angle | Min.: 0.0%, Max.: 100.0% |
| Accelerator Pedal Status | Accelerator Pedal Status | ON or OFF |
| Accelerator Position Sensor No.1 Voltage % | Accelerator pedal position sensor No. 1 | Min.: 0.00%, Max.: 100.00% |
| Accelerator Position Sensor No.2 Voltage % | Accelerator pedal position sensor No. 2 | Min.: 0.00%, Max.: 100.00% |
| Throttle Position Sensor No.1 Voltage % | Throttle position sensor | Min.: 0.00%, Max.: 100.00% |
| Master Cylinder Control Torque | Braking torque equivalent to master cylinder brake fluid pressure (Total braking torque) |
Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Brake Cancel Switch | Brake pedal status | ON or OFF |
| Shift Position | Current shift state | P / R / N / D / B |
| Shift Position (Meter) | Shift position of meter display | Not Displayed / P / R / N / D / B |
| Shift Switch Status (N,P Position) | Shift position status (N or P position) | ON or OFF |
| P Position Switch Terminal Voltage | P position switch voltage | Min: 0.00 V, Max: 4.99 V |
| Shift Sensor Voltage (VSI1) | Shift sensor (VSI1) voltage | Min: 0.00 V, Max: 4.99 V |
| Shift Sensor Voltage (VSI2) | Shift sensor (VSI2) voltage | Min: 0.00 V, Max: 4.99 V |
| Shift Sensor Voltage (VSI3) | Shift sensor (VSI3) voltage | Min: 0.00 V, Max: 4.99 V |
| Shift Sensor Voltage (VSI4) | Shift sensor (VSI4) voltage | Min: 0.00 V, Max: 4.99 V |
| Transaxle Oil Temperature | Hybrid vehicle transaxle oil temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Transaxle Oil Temperature Sensor Voltage | Hybrid vehicle transaxle oil temperature sensor voltage | Min: 0.00 V, Max: 4.99 V |
| FR Wheel Speed | Front wheel speed RH | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph) |
| FL Wheel Speed | Front wheel speed LH | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph) |
| RR Wheel Speed | Rear wheel speed RH | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph) |
| RL Wheel Speed | Rear wheel speed LH | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph) |
| Atmospheric Pressure | Atmospheric pressure | Min.: 0 kPa (0 psi), Max.: 255 kPa (37 psi) |
| Intake Manifold Absolute Pressure | Intake manifold pressure of engine | Min.: 0.00 kPa (0 psi), Max.: 2047.96 kPa (297 psi) |
| Ambient Temperature | Ambient air temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Intake Air Temperature | Engine intake air temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| BATT Voltage | Auxiliary battery voltage (Battery ECU assembly power source voltage) |
Min.: 0.00 V, Max.: 16.00 V |
| Smoothed Value of BATT Voltage | Smoothed value of auxiliary battery voltage | Min.: 0.00 V, Max.: 16.00 V |
| Warmup Cycle Cleared DTC | The number of times the engine is warmed up after clearing DTCs | Min.: 0, Max.: 255 |
| Distance from DTC Cleared | Drive distance after clearing DTCs | Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) |
| Time after DTC Cleared | Elapsed time after clearing DTCs | Min.: 0 min, Max.: 65535 min |
| Running Time from MIL ON | Running time from MIL on | Min.: 0 min, Max.: 65535 min |
| Total Distance Traveled | Drive total distance | Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile) |
| MIL ON Run Distance | Drive distance from MIL on | Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) |
| IG Switch (CAN) | Power switch status (CAN) | ON or OFF |
| IG Switch (LIN) | Power switch status (LIN) | ON or OFF |
| IGB Signal Status | IGB signal status | ON or OFF |
| IGB Keeping Status | IGB keeping status | ON or OFF |
| IG2 Signal Status | IG2 signal status | ON or OFF |
| +B3M Signal Status | +B3M signal status | ON or OFF |
| MRL2 Signal Status | MRL2 signal status | ON or OFF |
| ACC Signal | ACC signal status | ON or OFF |
| Ready Signal | Ready signal status | ON or OFF |
| HV Activate Condition | Hybrid vehicle control system power source mode status | Normal / Remote Air Control System / Remote |
| MG Activate Condition | Motor generator control system status | ON or OFF |
| DSS Control Status | Control status of DSS (Driving Support System) | Not Control / Available / Unavailable / Disable |
| Generate Torque (Request from DSS) | Generated drive torque requested from DSS (Driving Support System) | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Primary Driving Force Adjustment Result | Result of adjustment between drive force of DSS (Driving Support System) and drive force requested by accelerator pedal operation | Accelerator / DSS |
| SMRG Status | Operating state of SMRG (primary circuit monitor) |
ON or OFF |
| SMRG Control Status | Commanded state of SMRG | ON or OFF |
| SMRB Status | Operating state of SMRB (primary circuit monitor) |
ON or OFF |
| SMRB Control Status | Commanded state of SMRB | ON or OFF |
| SMRP Status | Operating state of SMRP (primary circuit monitor) |
ON or OFF |
| SMRP Control Status | Commanded state of SMRP | ON or OFF |
| WIN Control Limit Power | WIN control limit power | Min.: -327.68 kW, Max.: 327.67 kW |
| WOUT Control Limit Power | WOUT control limit power | Min.: -327.68 kW, Max.: 327.67 kW |
| Charging Permission Signal by Main CPU | Charging permission signal by main CPU | NG or OK |
| Charging Permission Signal by Sub CPU | Charging permission signal by sub CPU | NG or OK |
| Charging Permission Answerback Signal from Plug-in Control ECU | Charging permission answerback signal from plug-in control ECU | NG or OK |
| A/C Consumption Power | A/C consumption power | Min.: 0.00 kW, Max.: 12.75 kW |
| Powertrain Drive Mode Switch | Drive mode select switch (pattern select switch assembly) condition | ON or OFF |
| HV/EV Mode Switch | HV/EV mode switch status | ON or OFF |
| EVMS Signal Status | EV CITY switch or EV AUTO switch signal status | ON or OFF |
| Drive Mode | Drive mode status | None / EV Mode / HV Mode by Switch / HV Mode |
| Hybrid Control System Control Mode | Hybrid Control System Control Mode | None / Driving Mode / External Power Supply Mode / Charging/Discharging Mode / Other |
| Inter Lock Switch | Interlock switch condition | ON or OFF |
| Inter Lock Switch (MG) | Interlock switch condition | ON or OFF |
| Stop Light Switch | Stop light switch assembly condition | ON or OFF |
| Back Up Light Relay | Back up light switch condition | ON or OFF |
| VSC/TRC OFF Switch | VSC condition | OFF / TRC OFF Mode / TRC/VSC OFF Mode |
| Airbag Status (Collision) | Airbag ECU assembly collision detection | ON or OFF |
| Airbag Status (Collision) (CAN) | Airbag ECU assembly collision detection (CAN) |
Normal / Collision from Back / Airbag Circuit Abnormal / Safing / Collision from Front or Side |
| Airbag Status (Safing) | Safing state of the airbag ECU assembly | ON or OFF |
| Airbag Status (Normal) | Control state of airbag ECU assembly | ON or OFF |
| Crank Position | Crankshaft position | Min.: -128 deg (CA), Max.: 127 deg (CA) |
| TC Terminal | TC terminal state | ON or OFF |
| Remote Air Control System | Remote air conditioning system operability | Unable or Able |
| AC Charging | Plug-in charging operability | Unable or Able |
| Solar Charging | Solar charging operability*1 | Unable or Able |
| Elapsed time from HV ECU Boot Up | Time elapsed since hybrid vehicle control ECU started | Min.: 0 sec, Max.: 65535 sec |
| IG OFF Elapsed Time | Cumulative time since power switch turned off (from ECM) | Min.: 0 min, Max.: 655350 min |
| Generator Revolution | Generator (MG1) speed (detected by resolver sensor) | Min.: -32768 rpm, Max.: 32767 rpm |
| Target Generator Torque | Generator (MG1) torque request value | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Generator Torque | Generator (MG1) torque execution value | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Motor Revolution | Motor (MG2) speed (detected by resolver sensor) | Min.: -32768 rpm, Max.: 32767 rpm |
| Target Motor Torque | Motor (MG2) torque request value | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Motor Torque | Motor (MG2) torque execution value | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Request Motor Regenerative Brake Torque | Requested motor (MG2) regenerative braking torque | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Motor Regenerate Brake Execution Torque | Motor (MG2) regenerative braking execution torque | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Generator Temperature | Generator (MG1) temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Generator Temperature Sensor Voltage | Generator (MG1) temperature sensor voltage | Min.: 0 V, Max.: 4.99 V |
| Generator Temperature just after IG ON | Generator (MG1) temperature soon after power switch on (IG) | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Generator Maximum Temperature | Maximum generator (MG1) temperature after power switch turned on (IG) in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Motor Temperature | Motor (MG2) temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Motor Temperature Sensor Voltage | Motor (MG2) temperature sensor voltage | Min.: 0 V, Max.: 4.99 V |
| Motor Temperature just after IG ON | Motor (MG2) temperature soon after power switch on (IG) | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Motor Maximum Temperature | Maximum motor (MG2) temperature after power switch turned on (IG) in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Generator Inverter Calculated Temperature | Generator inverter temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Generator Inverter Calculated Temperature just after IG ON | Generator inverter temperature soon after power switch on (IG) | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Generator Inverter Calculated Maximum Temperature | Maximum generator inverter temperature after power switch turned on (IG) in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Motor Inverter Temperature | Motor inverter temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Motor Inverter Temperature just after IG ON | Motor inverter temperature soon after power switch on (IG) | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Motor Inverter Maximum Temperature | Maximum motor inverter temperature after power switch turned on (IG) in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Boosting Converter Temperature (Upper) | Boost converter temperature (upper) | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Boosting Converter Temperature (Lower) | Boost converter temperature (lower) | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Boosting Converter Temperature just after IG ON | Boost converter temperature soon after power switch on (IG) | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Boosting Converter Maximum Temperature | Maximum converter temperature after power switch turned on (IG) in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Generator Inverter Operation Request | Generator inverter operation request | Shutdown / Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement |
| Generator Inverter Fail | Generator inverter stopped | ON or OFF |
| Generator Inverter Shutdown Status | Generator inverter shutdown status | Awake or Shutdown |
| Motor Inverter Operation Request | Motor inverter operation request | Shutdown / Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement |
| Motor Inverter Fail | Motor inverter stopped | ON or OFF |
| Motor Inverter Shutdown Status | Motor inverter shutdown status | Awake or Shutdown |
| Boosting Converter Operation Request | Boosting converter operation request | Normal / Boosting Stop / Upper Arm ON / Maximum Boosting / Output Torque / Upper Arm Lowering |
| Boosting Converter Fail | Boost converter stopped | ON or OFF |
| Boosting Converter Shutdown Status | Boost converter shutdown status | Awake or Shutdown |
| Generator Carrier Frequency | Generator Carrier Frequency | 0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode |
| Generator Control Mode | Generator (MG1) control mode | Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode |
| Motor Carrier Frequency | Motor (MG2) carrier frequency | 0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode |
| Motor Control Mode | Motor (MG2) control mode | Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode |
| Boosting Converter Carrier Frequency | Boost converter signal carrier frequency | 9.55 kHz / 9.13 kHz / 8.71 kHz / 8.29 kHz / 7.87 kHz / 7.45 kHz / 4.80 kHz |
| VL-Voltage before Boosting | High voltage before it is boosted | Min.: 0.0 V, Max.: 32767.5 V |
| VH-Voltage after Boosting | High voltage after it is boosted | Min.: 0.0 V, Max.: 32767.5 V |
| Boost Ratio | Boost converter boost ratio | Min.: 0.0%, Max.: 100.0% |
| V Phase Generator Current | V phase generator current | Min.: -3276.8 A, Max.: 3276.7 A |
| W Phase Generator Current | W phase generator current | Min.: -3276.8 A, Max.: 3276.7 A |
| V Phase Motor Current | V phase motor current | Min.: -3276.8 A, Max.: 3276.7 A |
| W Phase Motor Current | W phase motor current | Min.: -3276.8 A, Max.: 3276.7 A |
| Inverter Coolant Water Temperature | Inverter coolant temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Inverter Water Pump Duty Ratio | Inverter water pump motor driver request duty | Min.: 0.0%, Max.: 100.0% |
| Inverter Water Pump Revolution | Inverter water pump assembly speed | Min.: 0 rpm, Max.: 15000 rpm |
| Overvoltage Input to Inverter | Overvoltage detection into inverter | ON or OFF |
| Inverter Emergency Shutdown (Main CPU) | Inverter emergency shutdown | ON or OFF |
| Inverter Emergency Shutdown (Sub CPU) | Inverter emergency shutdown | ON or OFF |
| Overvoltage Input to Boosting Converter | Overvoltage detection into boost converter | ON or OFF |
| Target Motor/Generator Cooling Oil Pump Motor Duty | Oil pump with motor assembly request duty | Min.: 0.0%, Max.: 100.0% |
| Motor/Generator Cooling Oil Pump Motor Revolution | Oil pump with motor assembly speed | Min.: 0 rpm, Max.: 65535 rpm |
| Motor/Generator Cooling Oil Pump Motor Power Relay Request | OIL PMP relay operation request | ON or OFF |
| Hybrid Battery SOC | HV battery state of charge Primary calculated from charging and discharging amperage |
Min.: 0.00%, Max.: 100.00% |
| Hybrid Battery SOC of Immediately after IG ON | HV battery state of charge soon after power switch on (IG) | Min.: 0.0%, Max.: 100.0% |
| Hybrid Battery Maximum SOC | Maximum SOC after power switch turned on (IG) in current trip | Min.: 0.0%, Max.: 100.0% |
| Hybrid Battery Minimum SOC | Minimum SOC after power switch turned on (IG) in current trip | Min.: 0.0%, Max.: 100.0% |
| Hybrid Battery Voltage | HV battery voltage | Min.: 0.00 V, Max.: 510.00 V |
| Hybrid Battery Current | HV battery current | Min.: -3276.8 A, Max.: 3276.7 A |
| Hybrid Battery Current for Driving Control | Hybrid battery current for driving control | Min.: -327.68 A, Max.: 327.67 A |
| Hybrid Battery Charging Power | HV battery charging power | Min.: -327.68 kW, Max.: 327.67 kW |
| Charging Voltage for Hybrid Battery | HV battery charging voltage (VCHG sensor value) | Min.: 0.0 V, Max.: 6553.5 V |
| Hybrid Battery Cooling Fan Low Speed Request | Battery cooling blower assembly Lo speed requested | ON or OFF |
| Short Wave Highest Value Level | Waveform voltage level in abnormal insulation detection circuit in battery ECU assembly | Not Judge / Normal / Insulation Lower LV2 / Insulation Lower LV3 |
| Insulation Resistance Division Check Completion using MG Inv | Insulation resistance division check completion using MG inv | Not Complete / Complete |
| Insulation Resistance Division Check Completion using A/C Inv | Insulation resistance division check completion using A/C inv | Not Complete / Complete |
| Insulation Resistance Division Check Completion using SMR | Insulation resistance division check completion using SMR | Not Complete / Complete |
| Short Wave Highest Value Availability just after MG Inv On/Off | Short wave highest value availability just after MG inv on/off | No or Yes |
| Short Wave Highest Value Availability just after A/C Inv On/Off | Short wave highest value availability just after A/C inv on/off | No or Yes |
| Short Wave Highest Value Availability just after SMR On/Off | Short wave highest value availability just after SMR on/off | No or Yes |
| Immobiliser Communication | Immobiliser communication line status | ON or OFF |
| Permit Start by Immobiliser | Status of starting permission by immobiliser (immobiliser to hybrid vehicle control ECU) | No Judgment / OK / NG |
| Auxiliary Battery Voltage | Auxiliary battery voltage | Min.: 0.00 V, Max.: 16.00 V |
| Auxiliary Battery Current | Auxiliary battery current | Min.: -125.00 A, Max.: 124.99 A |
| Smoothed Value of Auxiliary Battery Temperature | Smoothed value of auxiliary battery temperature | Min.: -40.0°C (-40.0°F), Max.: 6513.5°C (11756.3°F) |
| P Control Request Status | Shift control actuator assembly operation request | No Request / Lock(Normal) / Unlock(Normal) / Lock(Abnormal) / Unlock(Abnormal) |
| P Control Status | P position system status | Lock Position (Normal) / Lock Position (Abnormal) / Indefinite Position (Normal) / Indefinite Position (Abnormal) / Unlock Position (Normal) / Unlock Position (Abnormal) / Lock Position (Normal) / Lock Position (Abnormal) / Indefinite Position (Normal) / Indefinite Position (Abnormal) / Unlock Position (Normal) / Unlock Position (Abnormal) |
| Target P Position | Target shift position of shift control actuator assembly | Unlock / Incertitude / Lock |
| P Position Status | Park (P) shift state status | Unlock / Incertitude / Lock |
| P Position Status before Last | Previous park (P) shift state status | Unlock / Incertitude / Lock |
| Parking Lock Motor Position | Shift control actuator assembly position | Min.: -32768, Max.: 32767 |
| Parking Lock Motor Revolution | Shift control actuator assembly rotation speed | Min.: -32768 rpm, Max.: 32767 rpm Normal Operating Range: 0 to 2000 rpm |
| Parking Lock Motor Rotation Direction | Shift control actuator assembly operating direction | Unlock / Incertitude / Lock |
| Parking Lock Motor Control Mode | Shift control actuator assembly control mode | Startup / Initially Drive / Lock Position Learn / Unlock Position Learn / Lock Position Learning Complete / Unlock Position Learning Complete / P Position Change / Motor Control (Abnormal) |
| Parking Lock Motor Drive Mode | Shift control actuator assembly drive mode | No Control / Rotary Drive (Normal) / Stop / Rotation Direction Change Drive / Rotary Drive (Initial/Abnormal) |
| Parking Lock Motor Current Sensor Voltage | Shift control actuator assembly sensor voltage | Min.: 0 V, Max.: 4.99 V |
| Fail Safe Status (Shift Sensor) | Fail-safe control status during shift sensor malfunction | No Fail Safe / Fail Safe2 / Fail Safe3 / Fail Safe4 / Fail Safe5 |
| Fail Safe Status (Parking Lock Motor) | Fail-safe control status when shift control actuator assembly malfunction detected | No Fail Safe / Fail Safe1 / Fail Safe2 / Fail Safe3 / Fail Safe4 / Fail Safe5 |
| Fail Safe History (Parking Lock Motor Inoperative) | Shift control actuator assembly malfunction fail-safe control history | ON or OFF |
| W Phase Parking Lock Motor Current-Carrying Status | W phase current-carrying status | ON or OFF |
| V Phase Parking Lock Motor Current-Carrying Status | V phase current-carrying status | ON or OFF |
| U Phase Parking Lock Motor Current-Carrying Status | U phase current-carrying status | ON or OFF |
| W Phase Parking Lock Motor Terminal Voltage | Shift control actuator assembly (parking lock motor (W phase terminal voltage)) AD voltage (ECU recognized value) | Min.: 0 V, Max.: 4.99 V |
| V Phase Parking Lock Motor Terminal Voltage | Shift control actuator assembly (parking lock motor (V phase terminal voltage)) AD voltage (ECU recognized value) | Min.: 0 V, Max.: 4.99 V |
| U Phase Parking Lock Motor Terminal Voltage | Shift control actuator assembly (parking lock motor (U phase terminal voltage)) AD voltage (ECU recognized value) | Min.: 0 V, Max.: 4.99 V |
| Relay Cut Signal of Parking Lock Motor Power for Hybrid Control System | No. 1 integration relay (P-CON relay) | ON or OFF |
| Parking Lock Motor Relay Status for Transmission Control System | No. 1 integration relay (P-CON relay) | ON or OFF |
| Abnormality Informing Status | Malfunction information status | ON or OFF |
| Backup Status of Parking Lock Motor Control (Initial Drive) | Shift control actuator assembly malfunction (initial operation) | ON or OFF |
| Backup Status of Parking Lock Motor Control (P Position Change) | Shift control actuator assembly malfunction (When shift state changed to/from park (P)) | ON or OFF |
| Parking Lock Motor Circuit History | History of parking lock motor circuit malfunction | ON or OFF |
| P Position Change Delayed History | History of park (P) state change delay malfunction | ON or OFF |
| P Position Switch Indicator | P position switch indicator illumination status | ON or OFF |
| P Position Switch Indicator Dimming Request | P position switch indicator dim signal status | Non-dimming / Dimming |
| Meter Display Request (P Position Switch ON when Running) | Status of P position switch rejection notification | ON or OFF |
| Meter Display Request (Shift N Operation when Running) | Meter display request (shift N operation when running) | ON or OFF |
| Meter Display Request (Shift Operation Rejection) | Meter display request (shift operation rejection) | Min.: 0, Max.: 255 |
| Identifying Signal of Shift R/D Operation during Ready OFF | Entry & start ECU notice request (shift R/D operation during Ready off) | ON or OFF |
| BATT Voltage for Transmission Control System | +B voltage value | Min.: 0 V, Max.: 79.99V |
| IG Voltage for Transmission Control System | IG voltage value | Min.: 0 V, Max.: 79.99V |
| Lock Position Learning Value | Learned value of lock position | Min.: -32768, Max.: 32767 |
| Unlock Position Learning Value | Learned value of unlock position | Min.: -32768, Max.: 32767 |
| Complete of Learn Unlock Position | Completion of unlock position learning | OK or NG |
| Complete of Detect Unlock Position | Completion of detecting unlock position | OK or NG |
| Complete of Learn Lock Position | Completion of lock position learning | OK or NG |
| Complete of Detect Lock Position | Completion of detecting lock position | OK or NG |
| Complete of Initially Drive Parking Lock Control | Initial drive control completed | OK or NG |
| Effective Status of Braking Torque | Regenerative braking status | Not Available / Available |
| P Position Automatic Change Request | P position automatic change request | ON or OFF |
| Target Charging Power | Electric vehicle charger assembly requested power for charging | Min.: -327.68 kW, Max.: 327.67 kW |
| Charging Status | Hybrid vehicle control ECU recognized charging state | Stop / Preparing / Charging / Process to Stop |
| Elapsed Time after Charging Status Transition | Time elapsed since charging started | Min.: 0 ms, Max.: 655350 ms |
| Charger Operation Status | Electric vehicle charger assembly state output to hybrid vehicle control ECU | Stand by / Ready / Stop |
| Charger Start Request by Hybrid Control ECU | Electric vehicle charger assembly activation request (from hybrid vehicle control ECU) | ON or OFF |
| Charger Input Power | Electric vehicle charger assembly input power | Min.: 0 W, Max.: 327675 W |
| AC Input Current | Charging current sensor value (from charger inlet) |
Min.: 0.0 A, Max.: 25.5 A |
| AC Charging Negative Relay Drive Request | Commanded state of CHRG | ON or OFF |
| AC Charging Positive Relay Drive Request | Commanded state of CHRB | ON or OFF |
| AC Charging Precharge Relay Drive Request | Commanded state of CHRP | ON or OFF |
| AC Charging Negative Relay Status | Operating state of CHRG | ON or OFF |
| AC Charging Positive Relay Status | Operating state of CHRB | ON or OFF |
| AC Charging Precharge Relay Status | Operating state of CHRP | ON or OFF |
| Solar Charging Permission Signal by Main CPU | Solar charging permission signal from hybrid vehicle control ECU (main CPU)*1 | NG or OK |
| Solar Charging Permission Signal by Sub CPU | Solar charging permission signal from hybrid vehicle control ECU (sub CPU)*1 | NG or OK |
| Solar Charging Permission Answerback Signal from Solar Charging Control ECU | Solar charging permission answerback signal from Solar charging control ECU*1 | NG or OK |
| Solar Charge Hybrid Battery DC/DC Converter Drive Request | Solar charging system HV battery DC/DC boost converter operation request*1 | ON or OFF |
| Solar Charge Hybrid Battery DC/DC Converter Input Power | Solar charging system HV battery DC/DC boost converter input power*1 | Min: 0 W, Max: 65535 W |
| Smoothed Value of Solar Charge Hybrid Battery DC/DC Converter Input Voltage | Smoothed value of solar charging system HV battery DC/DC boost converter input voltage*1 | Min: 0 V, Max: 6553.5 V |
*1: w/ Solar charging system