HEATED OXYGEN SENSOR INSPECTION

PROCEDURE


  1. INSPECT HEATED OXYGEN SENSOR

    A003OBTC06
    *a

    Component without harness connected

    (Heated Oxygen Sensor)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (HT1B) - 2 (+B) 20°C (68°F) 5 to 10 Ω
      1 (HT1B) - 4 (E2) Always 10 kΩ or higher

      If the result is not as specified, replace the heated oxygen sensor.