CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during heated oxygen sensor removal/installation are shown below.
| Replaced Part or Performed Procedure | Necessary Procedure | Effect/Inoperative Function when Necessary Procedure not Performed | Link |
|---|---|---|---|
for SFI system (w/ Canister Pump Module) |
Inspection After Repair |
|
|
for SFI system (w/o Canister Pump Module) |
Inspection After Repair |
|
PROCEDURE
REMOVE NO. 2 ENGINE UNDER COVER
REMOVE FRONT CENTER FLOOR BRACE
Remove the 4 bolts and front center floor brace.
REMOVE HEATED OXYGEN SENSOR
CAUTION:
To prevent burns, do not touch the engine, exhaust pipe or other high temperature components while the engine is hot.
| *1 | Wire Harness Clamp Bracket |
Disconnect the heated oxygen sensor connector.
Remove the wire harness clamp.
Remove the wire harness clamp bracket from the heated oxygen sensor.
Using SST, remove the heated oxygen sensor from the front exhaust pipe assembly (TWC: Rear Catalyst).
Note
If the heated oxygen sensor has been struck or dropped, replace it.