CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during knock control sensor removal/installation are shown below.
| Replaced Part or Performed Procedure | Necessary Procedure | Effect/Inoperative Function when Necessary Procedure not Performed | Link |
|---|---|---|---|
for SFI system (w/ Canister Pump Module) |
Inspection After Repair |
|
|
for SFI system (w/o Canister Pump Module) |
Inspection After Repair |
|
PROCEDURE
REMOVE INTAKE MANIFOLD
REMOVE KNOCK CONTROL SENSOR
Disconnect the knock control sensor connector.
Remove the bolt and knock control sensor from the cylinder block sub-assembly.
Note
If the knock control sensor has been struck or dropped, replace it.