LUGGAGE COMPARTMENT DOOR OPENER MAIN SWITCH INSPECTION

PROCEDURE


  1. INSPECT LUGGAGE DOOR OPENING CANCEL SWITCH ASSEMBLY


    1. A01MH9LC02
      *a

      Component without harness connected

      (Luggage Door Opening Cancel Switch Assembly)

      *b Cancel Switch

      Check the resistance.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 - 2 Switch off (Not pressed) 10 kΩ or higher
        Switch on (Pressed) Below 1 Ω

        • If the result is not as specified, replace the luggage door opening cancel switch assembly.