RELAY INSPECTION

PROCEDURE


  1. INSPECT FR WIPER DEICER RELAY


    1. Check the resistance.


      1. A01MGFD

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher
        Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω

        Tech Tips

        If the result is not as specified, replace the front wiper deicer relay.

  2. INSPECT DEFOGGER RELAY


    1. A01MJRSN05

      Check the resistance.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        3 - 4 Auxiliary Battery voltage not applied between terminals 1 and 2 Below 1 Ω
        Auxiliary Battery voltage applied between terminals 1 and 2 10 kΩ or higher
        3 - 5 Auxiliary Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
        Auxiliary Battery voltage applied between terminals 1 and 2 Below 1 Ω

        Tech Tips

        If the result is not as specified, replace the defogger relay.