CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
Disconnect the G43 air conditioning amplifier assembly connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G43-21 (B) - Body ground | GR - Body ground | Power source (+B) | Power switch off | 11 to 14 V |
| G43-1 (IG+) - Body ground | B - Body ground | Power source (IG) | Power switch on (IG) | 11 to 14 V |
| Power switch off | Below 1 V | |||
| G43-14 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
Reconnect the G43 air conditioning amplifier assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G43-11 (CANH)*1 | LG | - | - | - |
| G43-12 (CANL)*1 | W | - | - | - |
| G43-38 (RDFG) - Body ground | B - Body ground | Rear defogger signal | Power switch on (IG), rear window defogger switch off | 11 to 14 V |
| Power switch on (IG), rear window defogger switch on | Below 1 V |
*1: Refer to FAIL-SAFE CHART for CAN communication system (for LHD or for RHD).
CHECK INTEGRATION CONTROL AND PANEL ASSEMBLY
Disconnect the G49 integration control and panel assembly connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G49-1 (+B) - G49-16 (GND) | LG - W-B | Power source (+B) | Power switch off | 11 to 14 V |
| G49-9 (IG+) - G49-16 (GND) | P - W-B | Power source (IG) | Power switch on (IG) | 11 to 14 V |
| Power switch off | Below 1 V | |||
| G49-16 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
Reconnect the G49 integration control and panel assembly connector.
Check waveform according to the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G49-4 (CANH)*1 | BR | - | - | - |
| G49-5 (CANL)*1 | W | - | - | - |
*1: Refer to the CAN communication system (for LHD or for RHD), FAIL-SAFE CHART.