PROCEDURE
INSPECT AIRCONDITIONER PRESSURE SENSOR
Check the wire harness.
Disconnect the A20 air conditioner pressure sensor connector.
Disconnect the G43 air conditioning amplifier assembly connector.
| *a | Front view of wire harness connector (Airconditioner Pressure Sensor) |
| *b | Front view of wire harness connector (Air Conditioner Amplifier Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
If the resistance is not as specified, repair the wire harness.
Check the voltage.
Connect the G43 air conditioning amplifier assembly connector.
| *a | Component without harness connected (Air Conditioning Pressure Sensor) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
If the voltage is not as specified, repair the wire harness or replace the air conditioning amplifier assembly.
Check the air conditioner pressure sensor.
Install a manifold gauge set.
Connect the A20 air conditioner pressure sensor connector.
Turn the power switch on (IG).
| *a | Component with harness connected (Air Conditioning Amplifier) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
If the voltage is not as specified, replace the air conditioner pressure sensor.