AIR CONDITIONING PRESSURE SENSOR INSTALLATION

PROCEDURE


  1. INSTALL AIRCONDITIONER PRESSURE SENSOR


    1. Remove the vinyl tape from the airconditioner tube and accessory assembly and connecting part of the air conditioner pressure sensor.

    2. Apply sufficiently compressor oil to a new O-ring and fitting surface of the airconditioner pressure sensor.

      Compressor Oil
      ND-OIL 12 or equivalent

      Note

      Keep the O-rings and O-ring fitting surfaces free of foreign matter.

    3. A01MJDFC02
      *a Turn
      *b Hold

      Using a 27 mm deep socket wrench, install the air conditioner pressure sensor.

      Torque:
      10.8 N*m  { 110 kgf*cm, 8 ft.*lbf }
    4. Connect the connector.

  2. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT

    Click here

  3. WARM UP COMPRESSOR

    Click here

  4. INSPECT FOR REFRIGERANT LEAK

    Click here