AMBIENT TEMPERATURE SENSOR INSPECTION

PROCEDURE


  1. INSPECT THERMISTOR ASSEMBLY (THERMISTOR ASSEMBLY (AMBIENT TEMPERATURE SENSOR))


    1. Check the resistance.


      1. A01MJSGC09
        *a

        Component without harness connected

        (Ambient Temperature Sensor)

        *b Sensing Portion
        *c Resistance (kΩ)
        *d Temperature (°C (°F))

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        1 - 2 10°C 3.00 to 3.73 kΩ
        15°C 2.45 to 2.88 kΩ
        20°C 1.95 to 2.30 kΩ
        25°C 1.60 to 1.80 kΩ
        30°C 1.28 to 1.47 kΩ
        35°C 1.00 to 1.22 kΩ
        40°C 0.80 to 1.00 kΩ
        45°C 0.65 to 0.85 kΩ
        50°C 0.50 to 0.70 kΩ
        55°C 0.44 to 0.60 kΩ
        60°C 0.36 to 0.50 kΩ

        Note


        • Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.

        • When measuring, the sensor temperature must be the same as the ambient temperature.

        • Use a thermometer to detect the ambient temperature of the installation area around the thermistor assembly (ambient temperature sensor).

        Tech Tips

        If the specified condition is not met, replace the ambient temperature sensor.