PROCEDURE
INSPECT AIR CONDITIONING THERMISTOR ASSEMBLY (HUMIDITY SENSOR)
| *a | Component without harness connected (air conditioning thermistor assembly (Glass Temperature Sensor)) |
| *b | Heat Conduction Sheet Part |
| *c | Resistance ( kΩ) |
| *d | Temperature (°C (°F)) |
Check the glass temperature sensor.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Hold the sensor only by its connector. Touching the sensor may change the resistance value.
Tech Tips
If the specified condition is not met, replace the (air conditioning thermistor assembly (glass temperature sensor)).
| *a | Component without harness connected (air conditioning thermistor assembly(Glass Surroundings Temperature Sensor)) |
| *b | Heat Conduction Sheet Part |
| *c | Resistance ( kΩ) |
| *d | Temperature (°C (°F)) |
Check the glass surroundings temperature sensor.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Hold the sensor only by its connector. Touching the sensor may change the resistance value.
Tech Tips
If the specified condition is not met, replace the (air conditioning thermistor assembly(glass surroundings temperature sensor)).
| *a | Component with harness connected (Air Conditioning Thermistor Assembly (Humidity Sensor)) |
| *b | Heat Conduction Sheet Part |
| *c | Voltage (V) |
| *d | Relative Humidity (%) |
Check the Humidity sensor.
Remove the air conditioning thermistor assembly (humidity sensor) with the connector still connected.
Turn the power switch on (IG).
Measure the voltage according to the value(s)in the table below.
| Standard Voltage | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Do not touch the sensor as body heat will affect the inspection results. When performing the inspection, hold the sensor by its connector.
Allow the sensor to acclimate to the ambient temperature and humidity before performing the inspection.
The specified voltages in the table above are based on inspections performed when the ambient temperature is 25°C(77°F).
Tech Tips
If the specified condition is not met, replace the air conditioning thermistor assembly (humidity sensor).