PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
REMOVE PIPING CLAMP
| *1 | No. 2 Air conditioner Tube and Accessory Assembly |
| *2 | Air conditioner Tube and Accessory Assembly |
Install SST to the piping clamp as shown in the illustration.
|
Push In |
Hold the air conditioner tube and accessory assembly and No. 2 air conditioner tube and accessory assembly with each hand and push in SST with both thumbs.
Note
Do not apply excessive force to the air conditioner tube and No. 2 air conditioner tube and accessory assembly as they may bend.
| *1 | Air conditioner Tube and Accessory Assembly |
| *a | Stopper |
|
Lift Up |
|
Pull Off |
Raise the stopper of SST and remove SST and the piping clamp together from the air conditioner tube and accessory assembly.
Remove the piping clamp from SST.
Remove the air conditioner tube and accessory assembly from the No. 2 air conditioner tube and accessory assembly.
Remove the 2 O-rings from the No. 2 air conditioner tube and accessory assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.